• Title/Summary/Keyword: GATE

Search Result 6,371, Processing Time 0.035 seconds

A Study on the Location and Spatial Organization Characteristics of the Royal Tombs Uireung (의릉(懿陵) 일원(一圓)의 입지(立地)와 공간구성특성(空間構成特性)에 관(關)한 연구(硏究))

  • Choi, Jong Hee;Kim, Heung Nyeon;Lee, Won;Eom, Tae Geon
    • Korean Journal of Heritage: History & Science
    • /
    • v.43 no.1
    • /
    • pp.212-235
    • /
    • 2010
  • The purpose of this study is to examine the characteristics of the location and the spatial composition of Uireung that is located in Seokgwan-dong, Seongbuk-gu, Seoul, in order to understand the landscape architectural characteristics. The results are as follows. First, Uireung is 6.4km from Changdeokgung Palace and 5.5km from Heunginjimun Gate. It did not violate the distance standard (40km) for the royal tombs according to Joseon Dynasty Neung-won Myo-je. Second, Uireung is in harmony with the nature and shows the authoritative characteristics of the royal authority through the spatial composition and rank(Entrance Area, Ceremonial Area, Burial Area). Third, there are burial mound, stone sheep, stone tiger, stone table, stone watch pillars in the upper platform, and stone civil official, stone horse, stone lantern in the middle platform, and stone military official, stone horse in the lower platform, and T-shape shrine, worship road in the ceremonial area. There is no pond and a tomb keeper residence, but the position, size, and form can be approximated through historical research materials. There are a colony of pine trees around the burial mound and 64 species of trees such as pine tree, zelcova tree, and fir tree below the burial mound.

Feature and Operation on Correlation for Royal (State operation) Storage of Baekjae (백제 왕실(국영) 창고시설의 특징과 운영)

  • So, Jae Yun
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.4
    • /
    • pp.22-37
    • /
    • 2012
  • Storage facility of the pre-historic Korea is classified into the subterranean, ground and overground types. The rectangular-shaped subterranean Storage facilities have been identified in the Pungnaptoseong, the Gong mountain fortress site and the Gwanbukri site. Feature no. 196 at Gyeongdang District in Pungnaptoseong yielded a large quantity of glazed potteries, and a wooden storage at the Gwanbukri site contained a large amount of fruit seeds. These storage facilities might be functioned as the warehouse for the highest group rather than the storage for the emergency such as war and flooding and stipend of government officials. This article subdivided into "state storage" on the concept of the former that "royal storage" on the concept of the latter. If it look on the state storage at large, this include the royal storage too. But it subdivided to help article understand because Baekjae changed from state storage to royal storage by change and specialization of system after 4th. The reason why the diversification of storage pits was closely related to the unification of local polities and the concentration of political power in the state-level. Therefore, it might reflect the political circumstances the ruling elites attempted to heighten their authority in terms of the organizing tax collecting system. And divided the time of storage is confirmed separative storage pits in the suburbs of capital city. There is hight probability of top local polities or nation that have possessional a role. This is to cover on frequent war in the Three States. On the other hand, state storage is located around ancent road that linked castle gate that is divided into center and periphery depending on function and position of storage. Center is located royal storage focusing in the presumed royal palace that periphery is located state storage to provide service to the public. It is presumed that located with the government office.

A Study on How Height and Weight Affects Glomerular Filtration Rate (신장과 체중의 변화가 사구체 여과율에 미치는 영향)

  • Park, A Rang;Choi, Jong Sook;Lee, Young Hee;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.40-44
    • /
    • 2019
  • Purpose Glomerular filtration rate (GFR) is an important index for evaluation of renal function, renal disease diagnosis and progress monitoring. Therefore, accurate measurement of GFR is clinically important. Among the factors that affect the GFR result, there have been many discussions on the methods such as the correction of the kidney depth, net syringe count, and the method of setting the ROI. However there has been no consideration of counting in the most basic factors like height and weight measurement. In this study, we investigate how height and weight changes affects the result of GFR and review the importance of standardized body measurements. Materials and Methods Fifty patients who underwent GFR test were randomly sampled and examined for changes in height and body weight within one month. From the normal patients without renal disease to the patients with severely decreased GFR, we applied the GFR formula of Gate with varying height and weight. Results: The result showed variation of the height at maximum three centimeters and six kilograms of weight. The first calculation of GFR was done with fixed height value and control variable as weight. Weight was incremented by one kilogram each time up to six kilograms. The GFR showed increased result with increasing weight. The result of GFR showed ten percent increase with six kilograms of weight increase. On the other hand, when height value was incremented by one centimeter up to three centimeters showed decreased GFR result with fixed weight value. Up to three centimeters of height increase showed two percent of decreased GFR with fixed weight. Conclusion This study showed varying GFR result when height and weight changes. Therefore it is clinically crucial not only to maintain and manage body measuring instrument but also to have a standardized measurement methods to derive accurate measured values and to achieve reproducibility.

Direction of Conservation and Management about Cultural Landscape of the Traditional Villages in Huizhou Region, China - Centered on IPA Analysis - (중국 휘주 지역 고촌락 문화경관 보전 관리 방안 - IPA 분석을 중심으로 -)

  • Zhang, Xiao Dong;Park, Jae Chul;Lin, Nan
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.21 no.3
    • /
    • pp.69-75
    • /
    • 2019
  • The purpose of this study is to provide the conservation management direction about cultural landscape of the traditional villages in the area of Huizhou through the importance-performance analysis. The results of the survey on the importance - performance of 261 people who had many visits to various cultural landscapes of Huizhou villages such as Hongchun, Sidichun etc. are as follows. It was appeared that the item of 'good air' is the highest level of importance and satisfaction and is best condition. The item of 'historical conservation' is the high level of importance, but the level of satisfaction is low, so continuous improvement is necessary. The item of 'Old garden conservation' has high satisfaction but low importance, so it needs to improve its importance through subsequent improvement. The item of 'Keeping of old cemetary and old tower' has low importance and satisfaction but it is above average, so continuous maintenance is needed. The items of 'Preservation of stone gate' and 'Preservation of famous man's birth house' all have slightly higher satisfaction and lower importance. Both items are highly satisfied with their importance, so they should avoid excessive efforts and maintain the present status. Satisfaction with the item of 'water environment and water quality' was the lowest, and the problem of the present condition is the most serious, and a major improvement is needed. The importance and satisfaction of 'Commercial development of old villages' was the lowest among all items. This item is causing serious problems and should provide an overall improvement way to drastically improve the importance and satisfaction. Concentration is necessary to improve the environment of the whole villages, to protect the ecological plants and animals in old villages, to transfer and improve the culture of old villages, to maintain sustainability of the villages, and to protect old temple and old rock in old villages. As the level of satisfaction with sustainability is the lowest in the part of 'Concentrate here', there is a great concern about sustainability. Therefore, it is necessary to focus on sustainability and concentrate on sustainable development.

Evaluation of Prevention System of Falls and Committing Suicide with Application Technology of Rollinder System (추락 및 투신자살 방지시스템의 조사 및 Rollinder System 적용기술)

  • Park, Sea-Man;Baek, Chung-Hyun;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.591-598
    • /
    • 2019
  • The statistics of committing suicide in S. Korea is ranked in top with serious attempts of falling among OECD countries since 2003. The rates is slightly dropped by 5 percent point, nevertheless the falling is still high for the age of over 10 years old and this matter must be solved. Most of the case of suicides are the falling based on a trend view of falling which is serious matter and cannot be solved easily for both domestic and foreign countries. For example, the steel net of falling prevent was installed in the Golden Gate Bridge costed by 200 million-dollar. In New Zealand, the steel net of falling prevention had been removed and re-installed beccause of the high suicide rates. Canada and Australia also surrounded the bridge with steel fences to prevent suicide without consideration of the beauty of bridge. Therefore, this paper suggested a comparison study on both falling prevention systems in all countries and patent technologies. Also, it covers the blocking skills of approach in both security and limited area. This paper suggested the technical Rollinder system equipped with the mechanical apprentice to prevent effectively the falling sucides and wall passing. Before the installation of Rollinder System by 2016, there were 33 person who tried to fall in the river in Machang Bridge. However, the number of the committing suicides were dramatically reduced to zero after the installation of the system.

Numerical Analysis on the Turbulence Patterns in The Scour Hole at The Downstream of Bed Protection (하상보호공 직하류부 세굴공의 난류양상에 관한 수치해석적 연구)

  • Lee, Jaelyong;Park, Sung Won;Yeom, Seongil;Ahn, Jungkyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.20-26
    • /
    • 2019
  • Where hydraulic structures are to be installed over the entire width of a river or stream, usually a bed protection structure is to be installed. However, a local scour occurs in which the river bed downstream of the river protection system is eroded due to the influence of the upstream flow characteristics. This local scour is dominant in the flow and turbulence characteristics at the boundary of the flow direction and in the material of the bed materials, and may gradually become dangerous over time. Therefore, in this study, we compared the turbulence patterns in the local scour hole at the downstream of the river bed protection with the results of the analysis of the mobile bed experiment, and compared with the application of OpenFoam, a three dimensional numerical analysis model. The distribution of depth-averaged relative turbulence intensities along the flow direction was analyzed. In addition to this result, the stabilization of scour hole was compared with the bed shear stress and Shields parameter, and the results were compared by changing the initial turbulent flow conditions. From the results, it was confirmed that the maximum depth of generation of the three-stage was dominantly developed by the magnitude of depth-averaged relative turbulence intensity rather than the mean flow velocity. This result also suggests that design, construction or gate control are needed to control the depth-averaged relative turbulence intensities in order to reduce or prevent the local scour faults that may occur in the downstream part of the bed protection.

Improvement of Operating Stabilities in Organic Field-Effect Transistors by Surface Modification on Polymeric Parylene Dielectrics (Parylene 고분자 유전체 표면제어를 통한 OFET의 소자 안정성 향상 연구)

  • Seo, Jungyoon;Oh, Seungteak;Choi, Giheon;Lee, Hwasung
    • Journal of Adhesion and Interface
    • /
    • v.22 no.3
    • /
    • pp.91-97
    • /
    • 2021
  • By introducing an organic interlayer on the Parylene C dielectric surface, the electrical device performances and the operating stabilities of organic field-effect transistors (OFETs) were improved. To achieve this goal, hexamethyldisilazane (HMDS) and octadecyltrichlorosilane (ODTS), as the organic interlayer materials, were used to control the surface energy of the Parylene C dielectrics. For the bare case used with the pristine Parylene C dielectrics, the field-effect mobility (μFET) and threshold voltage (Vth) of dinaphtho[2,3-b:2',3'-f ]thieno[3,2-b]- thiophene (DNTT) FET devices were measured at 0.12 cm2V-1s-1 and - 5.23 V, respectively. On the other hand, the OFET devices with HMDS- and ODTS-modified cases showed the improved μFET values of 0.32 and 0.34 cm2V-1s-1, respectively. More important point is that the μFET and Vth of the DNTT FET device with the ODTS-modified Parylene C dielectric presented the smallest changes during a repeated measurement of 1000 times, implying that it has the most stable operating stability. The results could be meaned that the organic interlayer, especially ODTS, effectively covers the Parylene C dielectric surface with alkyl chains and reduces the charge trapping at the interface region between active layer and dielectric, thereby improving the electrical operating stability.

New QECCs for Multiple Flip Error Correction (다중플립 오류정정을 위한 새로운 QECCs)

  • Park, Dong-Young;Kim, Baek-Ki
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.907-916
    • /
    • 2019
  • In this paper, we propose a new five-qubit multiple bit flip code that can completely protect the target qubit from all multiple bit flip errors using only CNOT gates. The proposed multiple bit flip codes can be easily extended to multiple phase flip codes by embedding Hadamard gate pairs in the root error section as in conventional single bit flip code. The multiple bit flip code and multiple phase flip code in this paper share the state vector error information by four auxiliary qubits. These four-qubit state vectors reflect the characteristic that all the multiple flip errors with Pauli X and Z corrections commonly include a specific root error. Using this feature, this paper shows that low-cost implementation is possible despite the QECC design for multiple-flip error correction by batch processing the detection and correction of Pauli X and Z root errors with only three CNOT gates. The five-qubit multiple bit flip code and multiple phase flip code proposed in this paper have 100% error correction rate and 50% error discrimination rate. All QECCs presented in this paper were verified using QCAD simulator.

Development of Convolutional Network-based Denoising Technique using Deep Reinforcement Learning in Computed Tomography (심층강화학습을 이용한 Convolutional Network 기반 전산화단층영상 잡음 저감 기술 개발)

  • Cho, Jenonghyo;Yim, Dobin;Nam, Kibok;Lee, Dahye;Lee, Seungwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.991-1001
    • /
    • 2020
  • Supervised deep learning technologies for improving the image quality of computed tomography (CT) need a lot of training data. When input images have different characteristics with training images, the technologies cause structural distortion in output images. In this study, an imaging model based on the deep reinforcement learning (DRL) was developed for overcoming the drawbacks of the supervised deep learning technologies and reducing noise in CT images. The DRL model was consisted of shared, value and policy networks, and the networks included convolutional layers, rectified linear unit (ReLU), dilation factors and gate rotation unit (GRU) in order to extract noise features from CT images and improve the performance of the DRL model. Also, the quality of the CT images obtained by using the DRL model was compared to that obtained by using the supervised deep learning model. The results showed that the image accuracy for the DRL model was higher than that for the supervised deep learning model, and the image noise for the DRL model was smaller than that for the supervised deep learning model. Also, the DRL model reduced the noise of the CT images, which had different characteristics with training images. Therefore, the DRL model is able to reduce image noise as well as maintain the structural information of CT images.

Numerical analysis of heat dissipation performance of heat sink for IGBT module depending on serpentine channel shape (수치 해석을 통한 절연 게이트 양극성 트랜지스터 모듈의 히트 싱크 유로 형상에 따른 방열 성능 분석)

  • Son, Jonghyun;Park, Sungkeun;Kim, Young-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.415-421
    • /
    • 2021
  • This study analyzed the effect on the cooling performance of the channel shape of a heat sink for an insulated gate bipolar transistor (IGBT). A serpentine channel was used for this analysis, and the parameter for the analysis was the number of curves. The analysis was conducted using computational fluid dynamics with the commercial software ANSYS fluent. One curve in the channel improved the heat dissipation performance of the heat sink by up to 8% compared to a straight-channel heat sink. However, two curves in the channel could not improve the heat discharge performance further. Instead, the two curves caused a higher pressure drop, which induces parasitic loss for the pumping of coolant. The pressure drop of the two-curve channel case was 2.48-2.55 times larger than that of a one-curve channel. This higher pressure drop decreased the heat discharge efficiency of the heat sink with two curves. The discharge heat per unit pressure drop was calculated, and the result of the straight heat sink was highest among the analyzed cases. This means that the heat discharge efficiency of the straight heat sink is the highest.