• 제목/요약/키워드: G418

검색결과 237건 처리시간 0.021초

In Vitro에 의한 유황피복요소(硫黃被覆尿素)와 Diuredio Isobutane의 이용효과(利用效果) 판정(判定) (An Estimation on the Efficiency of Utilization of Sulfur Coated Urea and Diuredio Isobutane in Vitro)

  • 이호일;이재구;최인혁
    • 대한수의학회지
    • /
    • 제22권2호
    • /
    • pp.111-114
    • /
    • 1982
  • In order to explore more efficient protein substitutes by improving the utilization of non-protein nitrogen compounds in ruminants, the experiment was undertaken. The effects of sulfur coated urea (SCU) and diuredio isobutane (DUIB) in the ruminal fluid on the concentration of $NH_3-N$, the total count of the ruminal ciliates and pH value were estimated in vitro. The results obtained from the experiment were as follows: 1. The pH of the media of the group added diuredio isobutane and sulfur costed urea tends to decrease slightly at 9 hours after the incubation, but no pH changes were observed in the media added urea alone. 2. The number of the ciliates in the ruminal fluid was slightly increased 9 hours after the incubation in all groups. 3. The concentrations of $NH_3-N$ in the ruminal fluid were gradually increased according to the incubation in vitro showing 418, 431 and $627{\mu}g/ml$ in the group added diuredio isobutane and 428, 569 and $792{\mu}g/ml$ in the group added sulfur coated urea at 0, 0.5 and 9 hours after the incubation, respectively.

  • PDF

Atmospheric chemical vapor deposition of graphene on molybdenum foil at different growth temperatures

  • Naghdi, Samira;Rhee, Kyong Yop;Kim, Man Tae;Jaleh, Babak;Park, Soo Jin
    • Carbon letters
    • /
    • 제18권
    • /
    • pp.37-42
    • /
    • 2016
  • Graphene was grown on molybdenum (Mo) foil by a chemical vapor deposition method at different growth temperatures (1000℃, 1100℃, and 1200℃). The properties of graphene were investigated by X-ray diffraction (XRD), X-ray photoelectron spectroscopy, and Raman spectroscopy. The results showed that the quality of the deposited graphene layer was affected by the growth temperature. XRD results showed the presence of a carbide phase on the Mo surface; the presence of carbide was more intense at 1200℃. Additionally, a higher I2D/IG ratio (0.418) was observed at 1200℃, which implies that there are fewer graphene layers at this temperature. The lowest ID/IG ratio (0.908) for the graphene layers was obtained at 1200℃, suggesting that graphene had fewer defects at this temperature. The size of the graphene domains was also calculated. We found that by increasing the growth temperature, the graphene domain size also increased.

튜브식 겔형 납축전지에 있어서 활물질 밀도에 따른 싸이클 수명 특성 (Influence of Filling Density in the Positive Active-material on the Cycle-life Performance of the Tubular Type Gelled Valve Regulated Lead Acid Batteries)

  • 윤연섭;김병관;이수;김규태
    • 공업화학
    • /
    • 제10권3호
    • /
    • pp.415-418
    • /
    • 1999
  • 튜브식 양극판과 겔전해액을 사용한 VRLA (valve regulated Iead-acid) 전지에 있어서 양극 활물질 (active material)의 충전 밀도에 따른 충 방전 싸이클 특성을 고찰하였다. VRLA전지에 사용된 양극 활물질의 밀도는 각각 3.2g/mL, 3.4g/mL 및 3.6g/ml 이었다. VRLA전지는 IU 방식 ($I_{max}=0.2C_{10}/10$, 상한 전압 2.40 v/cell)의 충전과, D.O.D 100%/C5의 방전 방법으로 충 방전 싸이클 수명 시험을 실시하였다. 시험은 $25{\pm}1^{\circ}C$의 항온항습기에서 실행하였다. 시험 결과 활물질 밀도별 VRLA전지의 초기 용량은 밀도와 무관하였다. 즉 3.4g/mL에서 가장 우수하였고, 3.6g/mL에서 가장 낮았다. 충 방전 싸이클에서의 특성은 3.6g/mL인 전지는 3.4g/mL와 거의 유사하였고, 3.2g/mL보다는 크게 우수하였다. 또한 VRLA 전지의 수분고갈 및 열화는 양극 활물질의 충전 밀도가 높을수록 적었다. 이상으로 충 방전 싸이클용 VRLA전지의 양극 활물질의 밀도는 3.4~3.6g/mL이 적절한 것으로 판단되었다.

  • PDF

Analysis of Flux Observers Using Parameter Sensitivity

  • Nam H.T.;Lee K.J.;Choi J.W.;Kim H.G.;Chun T.W.;Noh E.C.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.418-422
    • /
    • 2001
  • To achieve a high performance in direct vector control of induction motor, it is essential to correct estimation of rotor flux. The accuracy of flux observers for induction machines inherently depends on parameter sensitivity. This paper presents an analysis method for conventional flux observers using Parameter Sensitivity. The Parameter sensitivity is defined as the ratio of the percentage change in the system transfer function to the percentage change of the parameter variation. We define the ratio between real flux and estimated flux as the transfer function, and analyzed a parameter sensitivity of this transfer function by simulation.

  • PDF

Poly(methyl methacrylate-co-styrene)/Silicate Nanocomposites Synthesized by Multistep Emulsion Polymerization

  • Park, Yeong-Suk;Kim, Yoon-Kyung;Chung, In-Jae
    • Macromolecular Research
    • /
    • 제11권6호
    • /
    • pp.418-424
    • /
    • 2003
  • Exfoliated poly(methyl methacrylate-co-styrene) [P(MMA-co-ST)]/silicate nanocomposites were synthesized through a multistep emulsion polymerization. The methyl methacrylate monomers were polymerized first and then the styrene monomers were polymerized. The nanocomposites had core-shell structures consisting of PMMA (core) and PS (shell); these structures were confirmed by $^1$H NMR spectroscopy and TEM, respectively. P(MMA-co-ST) copolymers showed two molecular weight profiles and two glass transition temperatures (T$_{g}$) in GPC and DMA measurements. At 30 $^{\circ}C$, the nanocomposites exhibited 83 and 91 % increases in their storage moduli relative to the neat copolymer because the silicate layers were dispersed uniformly in the polymer matrix.x.

SHS 화학로에 의한 (Ti.W)C 복탄화물의 합성 및 기계적 특성에 관한 연구 (A Study on Synthesis and Mechanical Properties of (Ti.W)C Complex Carbide by SHS Chemical Furnace)

  • 이형복;오유근;이풍헌;장동환
    • 한국세라믹학회지
    • /
    • 제33권4호
    • /
    • pp.418-424
    • /
    • 1996
  • (Ti.W)C complex carbide was synthesized by self-propagating high temperature synthesis (SHS) chemical furnace. Attempt to find the optimal condition for synthesis of (Ti.W)C the effects of molar ratio of Ti:W:C on the synthesized powders and mechanical properties were investigated, Optimum molar ratio of these synthe-sized powder was Ti:W:C=0.7:0.2:1.0 The bulk density M,O.R Hardness Fracture toughness of (Ti.W)C complex carbide sintered at 200$0^{\circ}C$ for 60 min by hot-pressing under the pressure of 20 MPa were 7.6g/cm3, 475 MPa, 17,.7 GPa respectively.

  • PDF

GFP 및 hFSH Gene을 이용한 형질전환 복제수정란의 생산

  • 양병철;임기순;김동훈;이상기;박수봉;성환후;민관식;이연근;장원경
    • 한국동물번식학회:학술대회논문집
    • /
    • 한국동물번식학회 2003년도 학술발표대회 발표논문초록집
    • /
    • pp.42-42
    • /
    • 2003
  • 복제기술은 기존의 형질전환 동물 생산의 효율을 향상시킬 수 있는 기술로서 인정하고 있으며 또한 이를 이용하여 형질전환 동물의 생산이 이루어지고 있다. 따라서 본 연구는 표지유전자 (GFP)와 유용유전자 (hFSH)를 이용하여 임신 45일령에 채취한 태아섬유아세포에 transfection 하고, transfection 된 세포의 효율적인 선발과 이를 이용한 형질전환 복제 수정란을 생산하고자 실시하였다. 대조구 (KbFF), GFP (79KbFF-GFP c-3) 및 hFSH (79KbFF-hFSH n-1)에 공시한 세포는 모두 동일한 태아유래의 세포 (모 79, 부 KPN178,♂)를 이용하였다. pAB-eGFP와 hFSH 유전자는 각파 electroporation 방법을 이용하여 transfection 하고, 이를 2주 동안 G418로 배양하며 selection 하였다.

  • PDF

자세제어에 대한 청각자극의 효과 (The Effects of the Auditory Stimulus on Postural Control)

  • 김영;정진석;김남균
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.418-421
    • /
    • 1997
  • We examined the effect of the auditory stimulus on postural control. The auditory stimulus control system composed of 8 speakers ,the audio amplifier, the PPI interface and the sound controller. We measured the sway of head position and COP. Our result showed that the auditory stimulus was effective on postural control. It also indicated that the auditory stimulus system might be applied to clinical use as a new postural control training system.

  • PDF

개선된 T-gate기술로 제작한 초저잡음 AlGaAs/InGaAs/GaAs pseudomorphic HEMT 소자의 특성 (A super low noise characteristics of AlGaAs/InGaAs/GaAs pseudomorphic HEMTs fabricated by the improved T-Gate)

  • 이진희;윤형섭;최상수;박철순;박형무
    • 전자공학회논문지A
    • /
    • 제32A권3호
    • /
    • pp.118-123
    • /
    • 1995
  • We have successfully fabricated a super low noise pseudomorphic HEMT(PHEMT) device with AlGaAs/InGaAs/GaAs sturcture by using improved T-Gate which have increased a large gaet cross-sectional area about two times in comparision with those of conventional T-gate processes. The PHEMSTs with 0.15$\mu$m-long and 140$\mu$m-wide gates have eshibited a super low noise characteristics, the noise figure of 0.45dB with associated gain of 10.87dB at 12GHz. The cut-off rewuqncy of the device is 94gHz with a transconductance of 418mS/mm.

  • PDF

전자의료기기의 전자파 적합성 평가에 관한 연구 (A Study on the Electromagnetic Compatibility Evaluation of the Electronic Medical Instrumentation)

  • 송철규;김종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.418-421
    • /
    • 2002
  • The immunity testing in this study was performed to examine the conducted immunity and radiated immunity in medical instrumentation. Experiments were performed to assess the conducted emission and radiated emission of medical instrumentation such as MRI, ultrasound system, and electro surgical unit etc. The emission testing revolves around conducted emissions (high-frequency currents) on power lines and signal cables. Emission testing also looks at the output of energy through the air (called radiated emissions) and analyzes the strength of those radio-frequency signals generated unintentionally by the electrical medical device that is under test. Finally, this study would provide significant data for furture research or electromagnetic interference and compatibility test in medical instrumentation.

  • PDF