• Title/Summary/Keyword: G3 calculation

Search Result 365, Processing Time 0.032 seconds

Health Vulnerability Assessment for PM10 in Busan (부산지역 미세먼지에 대한 건강 취약성 평가)

  • Lee, Won-Jung;Hwang, Mi-Kyoung;Kim, Yoo-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.5
    • /
    • pp.355-366
    • /
    • 2014
  • Objectives: This study seeks to evaluate the vulnerability assessment of the human health sector for $PM_{10}$, which is reflected in the regional characteristics and related disease mortality rates for $PM_{10}$ in Busan over the period of 2006-2010. Methods: According to the vulnerability concept suggested by the Intergovernmental Panel on Climate Change (IPCC), vulnerability to $PM_{10}$ is comprised of the categories of exposure, sensitivity, and adaptive capacity. The indexes of the exposure and sensitivity categories indicate positive effects, while the adaptive capacity index indicates a negative effect on vulnerability to $PM_{10}$. Variables of each category were standardized by the rescaling method, and each regional relative vulnerability was computed through the vulnerability index calculation formula. Results: The regions with a high exposure index are Jung-Gu (transportation region) and Saha-Gu (industrial region). Major factors determining the exposure index are the $PM_{10}$ concentration, days of $PM_{10}{\geq}50$, ${\mu}g/m^3$, and $PM_{10}$ emissions. The regions that show a high sensitivity index are urban and rural regions; these commonly have a high mortality rate for related disease and vulnerable populations. The regions that have a high adaptive capacity index are Jung-Gu, Gangseo-Gu, and Busanjin-Gu, all of which have a high level of economic/welfare/health care factors. The high-vulnerability synthesis of the exposure, sensitivity, and adaptive capacity indexes show that Dong-Gu and Seo-Gu have a risk for $PM_{10}$ potential effects and a low adaptive capacity. Conclusions: This study presents the vulnerability index to $PM_{10}$ through a relative comparison using quantitative evaluation to draw regional priorities. Therefore, it provides basic data to reflect environmental health influences in favor of an adaptive policy limiting damage to human health caused by vulnerability to $PM_{10}$.

A study of fast Reliability evaluation for acyclic digraph using domination theory (Domination 이론을 이용한 acyclic digraph의 빠른 신뢰도 계산을 위한 연구)

  • 이광원
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 1996
  • The aim of this paper is to develop more fast algorithm for evaluation of the reliability of networks and system. It is illustrated with examples. This paper derived the algorithm to calculate the acyclic directed graph G(deals with the problem of the s-t graph). The language PASCAL was used to implement the algorithm. Three Examples are calculated and the calculation time is shorter than the time by program in $\ulcorner$21$\lrcorner.

  • PDF

Assessment of ECCMIX component in RELAP5 based on ECCS experiment

  • Song, Gongle;Zhang, Dalin;Su, G.H.;Chen, Guo;Tian, Wenxi;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.59-68
    • /
    • 2020
  • ECCMIX component was introduced in RELAP5/MOD3 for calculating the interfacial condensation. Compared to other existing components in RELAP5, user experience of ECCMIX component is restricted to developmental assessment applications. To evaluate the capability of the ECCMIX component, ECCS experiment was conducted which included single-phase and two-phase thermal mixing. The experiment was carried out with test sections containing a main pipe (70 mm inner diameter) and a branch pipe (21 mm inner diameter) under the atmospheric pressure. The steam mass flow in the main pipe ranged from 0 to 0.0347 kg/s, and the subcooled water mass flow in the branch pipe ranged from 0.0278 to 0.1389 kg/s. The comparison of the experimental data with the calculation results illuminated that although the ECCMIX component was more difficult to converge than Branch component, it was a more appropriate manner to simulate interfacial condensation under two-phase thermal mixing circumstance, while the two components had no differences under single-phase circumstance.

Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method

  • Yucel, Haluk;Zumrut, Senem;Nartturk, Recep Bora;Gedik, Gizem
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.526-532
    • /
    • 2019
  • In this study, an in-house $^{152}Eu$ calibration source was produced from a custom epoxy matrix with a density of ${\rho}=1.14g\;cm^{-3}$, which is chemically stable and durable form after its solidification. The homogeneity of $^{152}Eu$ in matrix was obtained better than 98%. For a Marinelli beaker geometry, an efficiency calibration procedure was applied to a n-type, coaxial, 78.5% relative efficient HPGe detector in the energy range of 121.7-1408.0 keV by using in-house $^{152}Eu$ calibration source. Then the measured efficiencies for Marinelli geometry were compared with the results calculated by MEFFTRAN and ANGLE softwares for the validation. Although MEFFTRAN and ANGLE have two different efficiency transfer algorithms to calculate the efficiencies, they usually need to use a reliable and accurate reference efficiency values as input data. Hence, reference efficiency values were obtained experimentally from a multinuclide standard source for the same detector-Marinelli geometry. In the present source characterization, the corrections required for self-absorption and true coincidence summing effects for $^{152}Eu$ gamma-rays were also obtained for a such close counting geometry condition. The experimental results confirmed the validity of efficiency calculations obtained by MEFFTRAN and ANGLE softwares that are calculation tools.

A Study on the Calculation of GHG Emissions from General Ships by Tier3 Method (일반선박의 Tier3 수준의 온실가스 배출량 산정에 관한 연구)

  • Bong, Choon-Keun;Park, Seong-Jin;Kim, Yong-Gu;Lee, Im-Hack;Lee, Hee-Kwan;Hwang, Ui-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.701-708
    • /
    • 2011
  • In this study, the emissions of GHG from general ships were calculated by Tier1 method based on the fuel consumption, and by Tier3 method based on the activities data such as power and SFOC of each engine, sailing characteristics (e.g. time and load factor, etc.) considering the ship type. In 2009, the emissions of GHG by Tier1 and Tier3 method were appeared 28.27 mega-ton $CO_{2eq}$ and 30.81 mega-ton $CO_{2eq}$. The emissions by Tier3 were slightly more than those by Tier1. We found that the values of the sailing characteristics for surveyed data are overestimated slightly. In the near future, more detailed researches for sailing characteristics considering ship types would be needed for sailing, anchoring, and berthing condition, etc.

Estimation of Characteristics and Methane Production Rate of Food Waste (음식물류 폐기물 특성 및 메탄 발생가능량 평가)

  • Lee, Min-Kyu;Kim, Kyung;Shin, Hyun-Gon;Bae, Ki-Hwan;Kim, Choong-Gon;Park, Joon-Seok
    • Clean Technology
    • /
    • v.25 no.3
    • /
    • pp.223-230
    • /
    • 2019
  • This research was performed to evaluate the characteristics of food waste from 5 areas in Gangwon Province, Korea and to predict the $CH_4$ gas production rate. Food wastes were sampled in July and September, 2017. The amount of methane gas generation was evaluated through the biochemical methane potential (BMP) test and a calculation method using chemical composition. Average bulk density and pH of the food wastes were in the range of $0.758{\sim}0.850g\;cm^{-3}$ and 4.29 ~ 4.75, respectively. By physical composition, vegetables were the highest with 56.43 ~ 72.81% with fruits recording 5.31 ~ 8.95%, cereals 1.60 ~ 18.73%, fish and meat 4.47 ~ 12.11%, and filtrate 1.76 ~ 3.64%. The average water content was 69.30 ~ 75.87%, and VS and ash content were 22.50 ~ 27.98% and 1.63 ~ 2.48%, respectively. In addition, $BOD_5$, $COD_{Cr}$, and $COD_{Mn}$ were in the ranges of $17,690.3{\sim}33,154.9mg\;L^{-1}$, $106,212.3{\sim}128,695.5mg\;L^{-1}$, and $51,266.1{\sim}63,426.3mg\;L^{-1}$, respectively. The NaCl content ranged from 0.81 to 1.17%. The results of elemental analysis showed that the contents of C, H, O, N, and S were 44.87 ~ 48.1%, 7.12 ~ 7.57%, 40.13 ~ 43.78%, 3.22 ~ 4.14%, and 0.00 ~ 0.02%, respectively. In a comparison of the methane production yield per VS mass of food waste, there was no significant difference between the cumulative amount (${0.303{\sim}0.354m_{CH4}}^3\;{kg_{VS}}^{-1}$) by the BMP test and the theoretical amount (${0.294{\sim}0.352m_{CH4}}^3\;{kg_{VS}}^{-1}$) calculated by chemical composition.

Calculation and measurement of optical coupling coefficient for bi-directional tancceiver module (양방향 송수신모듈 제작을 위한 광결합계수의 계산 및 측정)

  • Kim, J. D.;Choi, J. S.;Lee, S. H.;Cho, H. S.;Kim, J. S.;Kang, S. G.;Lee, H. T.;Hwang, N.;Joo, G. C.;Song, M. K.
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.500-506
    • /
    • 1999
  • We designed and fabricated a bidirectional optical transceiver module for low cost access network. An integrated chip forming a pin-PD on an 1.3 urn FP-LD was assembled by flip-chip bonding on a Si optical bench, a single mode fiber with an angled end facet was aligned passively with the integrated chip on V-groove of Si-optical bench. Gaussian beam theory was applied to evaluate the coupling coefficients as a function of some parameters such as alignment distance, angle of fiber end facet, vertical alignment error. The theory is also used to search the bottle-neck between transmittance and receiving coupling efficiency in the bi-directional optical system. Tn this paper, we confirmed that reduction of coupling efficiency by the vertical alignment error between laser beam and fiber core axis can be compensated by controlling the fiber facet angle. In the fabrication of sub-module, a'||'&'||' we made such that the fiber facet have a corn shape with an angled facet only core part, the reflection of transmitted laser beam from the fiber facet could be minimized below -35 dE in alignment distance of 2: 30 /J.m. In the same condition, transmitted output power of -12.1 dEm and responsivity of 0.2. AIW were obtained.

  • PDF

Analysis of Dose Rates from Steam Generators to be Replaced from Kori Unit 1 (고리 1호기 교체 증기발생기의 선량률 분석)

  • Shin, Sang-Woon;Son, Jung-Kwon;Cho, Chan-Hee;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.175-184
    • /
    • 1998
  • In order to calculate dose rates from steam generators to be replaced from Kori unit 1 in 1998, radionuclide inventories inside steam generator were evaluated from smear test results and measured dose rates from S/G tubes withdrawn for the metallographical examination of damaged tubes. Based on the inventories, contact dose rates and dose rates at 1 m from the surface of a steam generator were calculated using the QAD-CG computer code. Contact dose rates ranged from 11.5 mR/hr at the bottom of channel head to 37.7 mR/hr at the middle of shell barrel, and showed no significant difference with dose rates at 1 m from the surface of steam generator. Shielding effects of lead and carbon steel were compared to provide basic shielding data. Lead shield showed excellent shielding effects. Dose rate at 1 m from the middle of S/G shell barrel decreased from 38.6 mR/hr to 15.5 mR/hr with the lead shield of 2 mm thickness. However, carbon steel showed a poor shielding effect even with the thickness of 2.0 cm. This can be explained with the great differences in the attenuation effect and buildup factor between lead and carbon steel for low energy photons.

  • PDF

A Study on the Nutrients Intake and Physical Growth and Development of Junior High School Girls in Cheju Is. Area (제주지역(濟州地域) 여중학생(女中學生)의 영양실태(營養實態)와 성장발육(成長發育)에 관한 연구(硏究))

  • Hong, Yang-Ja
    • Journal of Nutrition and Health
    • /
    • v.8 no.4
    • /
    • pp.15-26
    • /
    • 1975
  • The purpose of this paper is to investigate the nutrients intake situation and the physical growth and development of junior high school girls in cheju island, the peculiar area in Korea, and to study every possible correlation ketween daily food intake and growth rate of them. Further, it made an attempt to research nutrition problems for them in this area and assist in their growth and development through proper nutritional marragement. The survey was conducted in seven sample schods selected randomly from all three districts -this is Bukcheju-gun, Namcheju-gun and cheju city-of cheju Island. Four hundred eighteen girls, aged thirteen years ald, in second year grade of junior high schools, were provided with prepared questionnaires. For six days, July $16{\sim}21$ in 1975, the respondents filled out the questionnaires. They were asked to keep record of what they ate each meat. Their mitrients intake were analyzed in accordance with their daily food intake records during a six day period. On the other side, including physical growth index calculated by means of weight and hight of the respondents, their school records were also investigated. Critical Ratio as well as percentage calculation were included for statistical analysis. The findings and results abtained are summarized as follows: (1) Living circumstance a) Average numbers of brother and sister in sampled pupils' family were five. b) Niety percent of the respondents were brought up by mother's milk at their infants and 45 percent of them were weaned at the age of 13 to 24 months. c) Fourty-six percent of them revealed irregulity in their meal time. d) The most favorite main dish was boiled rice mixed other cereals (34%), next bread (31%) and boiled noodle (26%), and kimchi was the most papular side dish (64%). (2) Nutrition survey a) The average calorie intake of a pupil per day was 1,783 cal. and the total calorie intake was composed of carbohydrate 73%, pratein 15%, fat 12% respectively. b) Carolie and nutrients were lower than the recommended level, except vitamins A,$B_1$ and Niacin, c) Average protein intake per day was 68g, which was relatively near to the recommended level, but in fact, most of them came from grain which is lacking in essential amino acids. The ratio of animal protein intake to tatal protein intake was 36%. d) Their average animal food intake was proportionated in 14% in their total food intake and the cereals consumed in the largest quantity at the level of 63% out of whole food groups. (3) The results of statistical analysis a) The correlation between the calorie intake and the physical growth index revealed statistical significancy at the level of P<.005. b) The correlation between the protein intake and the physical growth index revealed statistical significancy at the level of .01

  • PDF

THE PATIENTS' SATISFACTION FOLLOWING IMPLANT TREATMENT

  • Heo, Yoon-Young;Heo, Seong-Joo;Chang, Myung-Woo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.569-576
    • /
    • 2008
  • STATEMENT OF PROBLEM: While patient-centered outcomes are usually not reported, these may represent major aspects of the implant success for the patient. Use of a well-designed patient survey form can be an invaluable asset to the implant practitioners. PURPOSE: The objective of this study was to investigate patient satisfaction after implant therapy by means of a questionnaire. MATERIAL AND METHODS: South Korean patients (n = 100), who visited the dental examination center of Soon Chun Hyang university hospital, were asked to fill out the satisfaction questionnaire regarding aspects of cost, comfort, esthetics, chewing, gingival health, food impaction, phonetic aspect, screw loosening, and general satisfaction. Responses to statements were given on the Likert response scale. Four experimental groups of patients were distinguished with various location ($A_1,\;A_2,\;A_3$), year ($B_1,\;B_2,\;B_3$), number of implant replacements ($C_1,\;C_2,\;C_3$), and treatment cost ($D_1,\;D_2,\;D_3$). The reliability of the response scales was measured by calculation of its internal consistency, expressed as Cronbach's ${\alpha}$. The scales were distinguished by means of factor analysis method. Possible differences in scale scores among the groups were assessed by One-way ANOVA (${\alpha}$= 0.05). RESULTS: Patients responded to most of the statements with high satisfaction. But the mean scale score of statement about cost was low. After the verification of internal consistency and factor analysis, five components, e.g. general satisfaction, comfort, chewing efficiency, esthetics, and phonetic aspect were grouped together. These components could be explained with common meaning and the first factor was named as 'general satisfaction'. Differences in patient satisfaction on the scale with esthetics were present between patients who have been wearing the implant prosthesis less than three years and those more than seven years ($B_1<B_3$). CONCLUSION: The patients were generally satisfied with the outcome of implant treatment. But the patients' major complaint was high cost and while the statistically significant difference was not shown, the satisfaction scale about food impaction and esthetics was low. So the continuing efforts to make improvements about these problems are needed for the implant practitioners.