• 제목/요약/키워드: Fz

검색결과 205건 처리시간 0.021초

중성자 조사에 의해 생성된 점결함 연구 (A study on point defects induced with neutron irradiation in silicon wafer)

  • 김진현;류근걸
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.62-66
    • /
    • 2002
  • The conventional floating zone(FZ) crystal and Czochralski(CZ) silicon crystal have resistivity variations longitudinally as well as radially The resistivity variations of the conventional FZ and CZ crystal are not conformed to requirement of dopant distribution for power devices and thyristors. These resistivity variations in conventional cystals limits the reverse breakdown voltage that could be achieved and forced designers of high power diodes and thyristors to compromise the desired current-voltage characteristics. So to produce high Power diodes and thyristors, Neutron Transmutation Doping(NTD) technique is the one method just because NTD silicon provides very homogeneous distribution of doping concentration. This procedure involves the nuclear transmutation of silicon to phosphorus by bombardment of neutron to the crystal according to the reaction $^{30}$ Si(n,${\gamma}$)longrightarrow$^{31}$ Silongrightarrow(2.6 hr)$^{31}$ P+$\beta$$^{[-10]}$ . The radioactive isotope $^{31}$ Si is formed by $^{31}$ Si capturing a neutron, which then decays into the stable $^{31}$ P isotope (i.e., the donor atom), whose distribution is not dependent on the crystal growth parameters. In this research, neutron was irradiated on FZ silicon wafers which had high resistivity(1000~2000 Ω cm), for 26 and 8.3hours for samples of HTS-1 and HTS-2, and 13, 3.2, 2.0 hours for samples of IP-1, IP-2 and IP-3, respectively, to compare resistivity changes due to time differences. The designed resistivities were approached, which were 2.l Ωcm for HTS-1, 7.21 Ω cm for HTS-2, 1.792cm for IP-1, 6.83 Ωcm for IP-2, 9.23 Ωcm for IP-3, respectively. Point defects were investigated with Deep Level Transient Spectroscopy(DLTS). Four different defects were observed at 80K, 125K, 230K, and above 300K.

  • PDF

성인 체중을 고려한 로봇의 지능형 발을 위한 6축 힘/모멘트센서 개발 (Development of 6-Axis Force/Moment Sensor Considered Adult Weight for a Humanoid Robot's Foot)

  • 김갑순;윤정원
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.90-97
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor considered adult weight far an intelligent foot of humanoid robot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself and control the foot using the forces and moments. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to the foot, which is composed of Fx sensor, Fy sensor, Fz sensor, Mx sensor, My sensor and Mz sensor in a body. Each sensor should get the deferent rated load, because the applied forces and moments to foot in walking are deferent. Therefore, one of the important things in the sensor is to design each sensor with the deferent rated load and the same rated output. In this paper, a 6-axis force/moment sensor (rated load of Fx and Fy are 500Nm and Fz sensor is 1000N, and those of Mx and My are 18Nm, Mz sensor is 8Nm) for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using by ANSYS software (FEM (Finite Element Method) program). Then, a 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

주파수 통과대역필터가 작업 기억 관련 사건관련전위 P300에 미치는 영향 (Effects of the Frequency Band Pass Filter on the P300 Event-related Potential in the Working Memory)

  • 박웅식;이정우
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.131-138
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.

시열과제 운동학습 시 집중연습과 분산연습이 P300 출현시기에 미치는 영향 (Effects of Massed and Distributed Practice on P300 Latency in a Sequential Timing Task)

  • 권용현;이명희
    • The Journal of Korean Physical Therapy
    • /
    • 제26권4호
    • /
    • pp.234-239
    • /
    • 2014
  • Purpose: The purpose of this study is to use P300 latency to determine whether methods of motor learning in terms of massed and distributed practice can affect motor sequential learning in healthy adults. Methods: Twenty-four healthy subjects participated in this study. They were randomly allocated into three groups: a 10 minute, a 12 hour, and a 24 hour group. In the SRT task, eight numbers were adopted as auditory stimuli. During an experiment, participants were instructed to press the matching key as quickly and accurately as possible when one of the eight numbers was presented randomly. The subjects practiced for three sessions, each of which comprised five blocks of 40 serial reaction time tasks. While they practiced during these three sessions, P300 latency was measured. The data were analyzed using ANCOVA. Results: The P300 latency of Fz, Cz, and Pz decreased in all groups except for the Fz area of the 10 min group. Overall, the P300 latency of the 10 min group showed a smaller decrease compared with the 12 hr and 24 hr groups. Statistically, no significant differences in the Fz and Cz areas were observed among the three groups. The P300 latency in the Pz area of the 10 min group showed a significantly smaller decrease compared with the other groups. Conclusion: These findings suggest that short-term sequential motor training can alter brain functions such as the P300 latency. We also found that better acquisition of a motor skill was obtained with distributed practice of a task than with massed practice.

만성뇌졸중 환자의 일어서기 자세에 따른 수직지면반발력의 대칭성의 비교 (The Comparison of Symmetry of Vertical Ground Reaction Force on Pattern of Sit to Stand in the Chronic Stroke Patients)

  • 신화경;정진우;김연정
    • 한국운동역학회지
    • /
    • 제23권3호
    • /
    • pp.253-259
    • /
    • 2013
  • The purpose of this study is to evaluate the influence of posture elements on symmetrical weight bearing during STS (sit-to-stand) in patients with chronic stroke. The subjects were patients diagnosed with stroke: a total of 24 patients (16 males and 8 females) participated in this study. All the participants performed STS tasks(3 foot postures and 2 arm postures). Two force plates (AMTI) were used to measure the peak vertical ground reaction force(Peak Fz) and the symmetrical ratio to peak vertical ground reaction force. The data were analyzed using independent t-test and 2-way repeated analysis of variance. The results of this study were as follows: 1) The peak Fz placed more weight on the paretic leg during STS and 2) The symmetrical ratio to the peak Fz showed a significant difference according to the foot and arm posture (p<.05), and had the highest AYM_GA ($0.87{\pm}0.12$). These results indicate that arm and leg postures during STS in patients with chronic stroke had the highest AYM_GA. We believe that the outcome of this study will be a reference for the prognosis of STS in patients with stroke.

ERP와 동공 반응을 이용한 숨긴정보검사 (Concealed information test using ERPs and pupillary responses)

  • 엄진섭;박광배;손진훈
    • 감성과학
    • /
    • 제15권2호
    • /
    • pp.259-268
    • /
    • 2012
  • P300-기반 숨긴정보검사(P300 CIT)에서, 조사대상자에게 관련자극이 가치가 있는 정도는 검사결과에 큰 영향을 미친다. 관련자극의 가치가 낮을 경우, P300 CIT의 정확판단율은 낮아진다. 본 연구의 목적은 관련자극의 가치가 낮은 경우, 동공-기반 숨긴정보검사(Pupil CIT)가 P300 CIT를 보완하는 검사로 사용될 수 있는지를 파악하는 것이다. 25명의 실험참여자에게 5장(스페이드 2, 3, 4, 5, 6)의 카드 중 한 장을 뽑도록 한 다음, 실험참여자가 뽑은 카드를 숨기정보로 사용한 P300 CIT와 Pupil CIT를 실시하였다. P300은 Fz와 Cz, Pz에서 측정하였으며, 동공크기는 양쪽 눈에서 모두 측정하였다. P300 CIT에서, Fz와 Cz, Pz에서 측정한 관련자극의 P300 진폭은 무관련자극의 P300 진폭보다 통계적으로 유의하게 더 컸다. Pupil CIT에서, 왼쪽 눈과 오른쪽 눈의 동공크기는 무관련자극이 제시되었을 때보다 관련자극이 제시되었을 때 더 컸다. P300 CIT의 정확판단율은 Fz와 Cz에서 44%였으며, Pz에서 36%였다. Pupil CIT의 정확판단율은 왼쪽 눈의 동공크기를 이용한 경우 52%였으며, 오른쪽눈의 동공크기를 이용한 경우 60%였다. 전체 사례수가 크지 않아 통계적으로 유의하지는 않았지만, Pupil CIT의 정확판단율이 P300 CIT의 정확판단율보다 높은 경향이 있었다. P300 CIT의 판단과 Pupil CIT의 판단 간의 상관관계는 통계적으로 유의하지 않았다. 결과적으로, 조사대상자에게 관련자극의 가치가 높지 않을 경우에는 P300 CIT 보다는 Pupil CIT를 사용하는 것이 더 좋을 것이다. 그리고 두 가지 검사방식을 결합한다면, 더욱 높은 정확도를 가진 숨긴정보검사를 구성할 수 있을 것이다.

  • PDF

수리영역 개념을 적용한 단열암반의 지하수유동체계 해석 (Analysis of a Groundwater Flow System in Fractured Rock Mass Using the Concept of Hydraulic Compartment)

  • 조성일;김천수;배대석;김경수;송무영
    • 지질공학
    • /
    • 제16권1호
    • /
    • pp.69-83
    • /
    • 2006
  • 본 연구는 지하유류저장공동 굴착 시 조사된 단열체계 및 수리 인자를 토대로 투수성구조영역과 수리암반영역으로 세분화하여 연구지역의 불규칙하고 복잡한 지하수유동체계를 해석해 보고자 하였다. 지하공동 내에서 확인된 단열분포특성과 지하공동굴착과 동시에 지표관측공 28개를 통해 측정된 지하수위 및 수평수벽공 95개와 수직수벽공 63개에 의해 일별로 계측된 압력 및 주입량을 통해 연구지역은 지하수의 방벽역할을 하는 3개의 투수성구조영역과 4개의 수리암반영역으로 구분이 가능하였다. 공동심도에 발달된 투수성 구조는 국지적 큰 규모 단열대인 NE-1과 2개의 국지규모 단열대로 구성되고 있으나, 수리암반영역은 국지규모 단열대에 의하여 4개 영역으로 구분된다. FZ-2 구조대와 인접한 수리암반영역 Domain-A와 B는 수평수벽공의 초기압이 최대 약 $15kg/cm^2$까지 높으며, 지하공동 굴착 시 상 하부의 지하수위변화의 차이가 $10\sim40m$로 상 하부의 수리적 연결성이 양호한 것으로 평가된다. 반면, FZ-1 구조대와 인접한 Domain-C와 D는 이중수위측정 시설 설치시 상부와 하부의 지하수위차는 최대 약 120 m로 매우 크게 나타났으며, 상부 지하수는 공동굴착 시 수위 가 크게 변화하지 않았다. Domain C, D의 하부암반의 수리 전도도$(7.2X10^{-10}m/sec)$는 상대적으로 낮은 지하수 함양량의 원인을 제공하고 있으며, 연속체개념 의 지하수유동모델링을 통해 계산된 4개 영역의 함양량은 연구지역의 20년간 평균 강수량(1,356 mm/year)의 2%로 계산되었다.

주의력 결핍 ${\cdot}$ 과잉행동장애 아동에서 Methylphenidate에 의한 사건관련전위와 연속과제수행 변화사이의 상관성 (RELATIONSHIP BETWEEN CHANGES IN EVENT-RELATED POTENTIALS AND CHANGES IN CONTINUOUS PERFORMANCE TEST UNDER THE INFLUENCE OF METHYLPHENIDATE IN ATTENTION-DEFICIT/HYPERACTIVITY DISORDER)

  • 최영;이무석;이미숙
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제8권2호
    • /
    • pp.273-286
    • /
    • 1997
  • 본 연구는 주의력결핍 ${\cdot}$ 과잉행동장애 환아에서 사건관련전위와 연속과제수행에 대한 methylphenidate(MPH)의 영향을 평가하고 사건관련전위의 변화와 연속과제수행의 변화 사이의 상관성을 알아보고자 시행되었다. 11명의 주의력결핍 ${\cdot}$ 과잉행동장애 남아에서 MPH(0.5mg/kg)의 급성효과를 알아보기위하여 사건관련전위와 연속과제수행검사를 시행하여 다음과 같은 결과를 얻었다. 약물 투여후, Fz에서 표준자극에 대한 P3 잠복기가 유의하게 감소하였고 Pz, Oz에서 표적자극에 대한 P2 진폭, 그리고 Cz에서 표적자극에 대한 P3 진폭이 유의하게 증가하였다. 또한 CPT-X 파라다임에서 탈락수와 오보수, 그리고 CPT-AX 파라다임에서 오보수가 유의하게 감소하였으며 CPT-X 파라다임의 반응의 정확도(the number of correct responses to targets, Hits)와 민감도(Perceptual sensitivity, d') 그리고 CPT-AX 파라다임의 민감도가 유의하게 증가하였다. 마지막으로 Fz에서 표적자극에 대한 P3 잠복기의 변화와 CPT-AX 파라다임의 민감도의 변화사이에는 음의 상관(p<0.05)이 있었고 Pz에서의 표적자극에 대한 P2 진폭의 변화와 CPT-X 파라다임의 민감도의 변화 사이에는 유의한 양의 상관(p<0.05)이 있었다. 결론적으로 MPH는 주의력결핍 ${\cdot}$ 과잉행동장애 아동에서 변화지향반응, 과제와 연관된 자극에 대한 반응, 정확도, 민감도를 개선시키며 비표적자극으로부터 표적자극을 구별하는 능력의 증가는 큰 기억요소를 요하는 과제에서는 자극 평가시간의 단축을 반영하며 단순과제에서는 변화지향반응의 개선을 반영하는 것으로 나타났다.

  • PDF

고역통과필터 값이 P300의 파형에 미치는 영향 (Effects of high pass filter settings on P300 waveform)

  • 엄진섭;음영지;손진훈;박광배
    • 감성과학
    • /
    • 제13권1호
    • /
    • pp.179-186
    • /
    • 2010
  • 본 연구는 Duncan-Johnson과 Donchin(1979)과 Soskins, Rosenfeld와 Niendam(2001)의 연구를 부분적으로 확장한 것으로, EEG를 측정할 때 사용하는 고역통과필터의 값이 P300의 파형에 미치는 영향을 관찰하였다. 시각자극을 이용한 세자극 오드볼 과제를 수행하는 동안 뇌파를 측정하였으며, Fz와 Pz에서 측정한 뇌파를 0.01Hz, 0.3Hz와 1.0Hz의 고역통과필터를 사용하여 여과시켰다. 0.3Hz의 고역통과필터를 사용한 경우에는 P300 진폭이 크게 감소하지 않았지만, 1.0Hz의 고역통과필터는 P300의 진폭을 크게 감소시켰다. 0.01Hz의 고역통과 필터를 사용한 경우에는 P300 이후 부적 정점이 나타나지 않았으며, 0.3Hz와 1.0Hz의 고역통과필터를 사용한 경우에는 P300 이후 부적 정점이 관찰되었다. 비목표자극과 표준자극에 대한 P300의 진폭을 변별할 때에는 0.3Hz 고역통과필터와 정점-정점 P300 측정치를 사용하는 것이 0.01Hz나 0.3Hz, 1.0Hz 고역통과필터와 기저선-정점 측정치를 사용하는 것보다 더 효율적인 경향이 있었으며, 1.0Hz의 고역통과필터를 사용한 경우에는 정점-정점 P300 측정치가 기저선-정점 P300 측정치보다 더 유용한 경향이 있었다.

  • PDF

여러 레진계 치아고정 재료의 굴곡강도 및 탄성계수 비교 (Comparison of flexural strength and modulus of elasticity in several resinous teeth splinting materials)

  • 유제인;김수연;;김진우;박세희;조경모
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.169-175
    • /
    • 2016
  • 목적: 본 연구의 목적은 수종의 레진계 치아고정 재료의 굴곡강도와 탄성계수를 비교 분석하는 것이다. 연구 재료 및 방법: 레진계 치아고정 재료로 Super-Bond C&B (SB), G-FIX (GF), G-aenial Universal Flo (GU), Filtek Z350 XT (FZ)를 이용하여 각 군당 15개씩 총 60개의 시편을 제작하였다. 3점 굽힘 시험으로 측정된 값에 따라 굴곡강도와 탄성계수를 계산하였다. 실험값은 One-way ANOVA test로 분석하고, Scheffe's test로 사후 검정하였다. 결과: 본 연구의 결과 SB는 다른 재료들과 비교 시 가장 낮은 굴곡강도를 보였으며 GF, GU, FZ는 비슷하게 높은 굴곡강도를 보였다. 탄성계수의 경우 SB가 가장 낮은 값을 보였고 GF는 SB보다는 높지만 GU와 FZ보다는 낮은 탄성계수를 보였으며 GU와 FZ는 유의하게 높은 탄성계수를 보였다. 결론: 동요치 고정을 목적으로 새로 개발된 GU (G-FIX)는 유동성 복합 레진과 수복용 복합 레진과 같이 높은 강도를 보이며 잘 파절되지 않으면서도 상대적으로 유연한 성질을 보여 동요치 고정에 유리할 것으로 사료된다.