• Title/Summary/Keyword: Fusing time

Search Result 83, Processing Time 0.033 seconds

Evaluation for Warming-up Performance and Fusing Quality through Heat Transfer Simulations of Laser Printer Fusing System (레이저 프린터 정착 시스템의 열전달 해석을 통한 승온 성능 및 정착성 예측)

  • Lee, Jin-sung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2231-2235
    • /
    • 2008
  • Thermal performance of fusing system in laser printer is determined by FPOT(First print out time) required and toner fusing quality. FPOT is influenced by the thermal resistance of fusing system between heat source and nip region. Also FPOT is depended by the heat source power and toner fusing temperature. The fusing quality of toner is decided by the temperature, pressure and duration time in nip region. In this study, I have performed thermal analysis for the toner fusing system. Computational simulation has been used to understand the effect of heat source power and printing speed etc. on the temperature distribution of the fusing system. Also in order to predict fusing quality, numerical simulation of the process that paper is continuously supplied to the nip regions were performed. In comparison with the experimental results of the fusing quality vs transferred calory to the toner layer, I could evaluate various fusing condition parameters effected on the thermal performance.

  • PDF

The Analysis of Metallurgical Structure and Arc Properties of Copper Wire Due to Over-current (과전류에 의한 동 전선의 용단 아크 특성 및 금속조직 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Dong-Ook;Lee, Ki-Yeon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.554-555
    • /
    • 2005
  • In this paper, we analyzed a metallurgical structure and arc properties of copper wire when the over-current flows on electric wire. From the results, The fusing current was related to the fusing time(current rising rate per second). In case of the shorter the fusing time, the fusing current was high, and the fusing time of ac type was larger than that of dc type. The copper wire was bent by the increase of current and heated, the beads were scattered around wire with a flash. We could observed the dendrite structure in 'molten wire at ac and dc current type. According as the current rising rate per second is short, the dendrite structure is distributed in surface of wire.

  • PDF

A Study on the Fusing Temperature Distribution for Laser Printer Toner by Using Numerical Computation

  • Choi, Yoon-Hwan;Lee, Yeon-Won;Kim, Dong-Kyun;Doh, Deog-Hee
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.5-8
    • /
    • 2009
  • Fusing process of laser printer is the step to fuse toner on the paper and it has a great effect on fast printing speed, decrease in waiting time and improvement of printing quality. In order to improve the quality of fusing, a study on the fusion region is required. Recently, various researches are progressing in this field. In this study, the research about the temperature distribution of fusing region is performed through numerical analysis because fusing region is one of the important factors influencing fusing quality. According to results, it is ascertained that the temperature of fusing region is relative to velocity of the paper under print and has a regular distribution to width direction of the paper.

Fusing Time Characteristics Analysis of Cable according to Temperature and Insulator (온도 및 절연체에 따른 케이블의 단선시간 특성 해석)

  • Kim, Ju-Hee;Kang, Sin-Dong;Kim, Jae-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.15-20
    • /
    • 2018
  • This paper describes the fusing time characteristics of Light PVC Sheathed Circular Cord(VCTF) and Tray Frame Retardant(TFR) cables according to increased temperature under over current condition. The experimental equation will be used to determine the validity and reliability of the test results. The over current flowed 3, 5 and 10 times higher than the amount of allowable current using DC power supply with DAQ(Data Acquisition) measurement system. An infrared radiation heater, which was controlled by a variable AC auto transformer, was used to increase the temperature from room temperature to 50, 100 and 150 degrees Celsius. First, two type of cables were analyzed those with different cross-sectional areas with in the same structure and those with different structures with in the same cross-sectional areas. Then, it was determined how fusing time had been influenced according to the cross-sectional areas and different structures, respectively. The cable resistance was increased by joule heating according to increasing temperature. Therefore, the allowable current of cable is decreased. Finally, the fusing time of the cable was decreased due to increased temperatures at current flow, which were 3 times the amount of allowable current. The instantaneous breakdown was observed when current flow was 5 and 10 times over the amount of allowable current. The fusing time is directly affected by the structure of cable insulation.

A Study on the Press Belt Motion in the Fusing Press M/C (심지융착기의 압착벨트 운동에 대한 연구)

  • Huh You;Ahn Seong-Gi;Jang Seung-Ho
    • Textile Coloration and Finishing
    • /
    • v.17 no.5 s.84
    • /
    • pp.53-60
    • /
    • 2005
  • Fusing press m/c is used for heating and pressing the specimens that are fed into between the two moving belts. Therefore the belt movement, belt temperature, and the pressure between belts must be kept constant. Especially, the belts should move in a limited operation range. When the belts run far out of the operation point, the machine has to be stopped, which results in a product defect because the fusing conditions, e.g., temperature and pressure, change during the transient process time period. It is important to avoid the belt stopping by maintaining the belt movement in a limited range. This study reports about the movement of the endless fusing belt in a long-span roller fusing m/c. The belt position changes as the 1st-order system does; if the roller axes are slanting each other with a certain angle, the belt running around the two rolls shows a dynamic behavior with the time that deviates fastly at the beginning from the initial condion and slows down. Then it reaches at a final position. The skewer the axes, the greater the position change. The inital change rate of the belt becomes large as the skewness of the axes between the two rollers increases.

Effect of Spraying Conditions in Flame Spraying of Ni-Cr Base Self Fluxing Alloy on Mild Steel (가스용사에 의한 Ni-Cr 기 자용성합금 용사 의 특성에 미치는 용사조건의 영향)

  • 배종규;박경채;정인상
    • Journal of the Korean institute of surface engineering
    • /
    • v.22 no.1
    • /
    • pp.26-42
    • /
    • 1989
  • It has between investigated that the optimum spaying conditions, such as, spraying distance, fusing temperature and fusing time, ect, in a Ni-cr base self fluxing alloy sprayed on the mild steel substrate by oxygen-acetylenc flame spraying. Sprayed specimens on various conditions were fuused in a vacuum furnace and the results were as follows. The optimum spraying condition for excellent coating layer are obtained under spraying distances, fusing temperature and fusing and time ; 180~240mm,1050~110$0^{\circ}C$and 15~30min, respectively. The adhesive strength and surface hurface hardness of the as sprayed specimens were very low by mechanical bonding becaus of the diffusion layer during process. The carbides and borides and formed in the sprayed coating layer and densification of the layer was resulted from the elimination of pores and oxides. The hardness of sprayed coating layer, particularly in the high temperature, was superior to ordinary tool steels.

  • PDF

A development of travel time estimation algorithm fusing GPS probe and loop detector (GPS probe 및 루프 검지기 자료의 융합을 통한 통행시간추정 알고리즘 개발)

  • 정연식;최기주
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.3
    • /
    • pp.97-116
    • /
    • 1999
  • The growing demand for the real time traffic information is bringing about the category and number of traffic collection mechanism in the era of ITS. There are, however, two problems in making data into information using various traffic data. First, the information making process of making data into the representative information, for each traffic collection mechanism, for the specified analysis periods is required. Second, the integration process of fusing each representative information into "the information" for each link out of each source is also required. That is, both data reduction and/or data to information process and information fusion are required. This article is focusing on the development of information fusing algorithm based on voting technique, fuzzy regression, and, Bayesian pooling technique for estimating the dynamic link travel time of networks. The proposed algorithm has been validated using the field experiment data out of GPS probes and detectors over the roadways and the estimated link travel time from the algorithm is proved to be more useful than the mere arithmetic mean from each traffic source.

  • PDF

Changes of Shape retention and Total Appearance Value(TAV) After Fusing (접착포의 형태 보형성(shape retention)과 TAV(Total Appearance Value)의 변화)

  • 지주원;유효선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1015-1024
    • /
    • 2000
  • The purpose of this study is 1) to analyse the bending property of the fused fabric and each component of the fused fabrics. 2) to examine the effect of fusing temperature on the bending property of the fused interlining and fused fabrics. 3) to examine the changes of B/W, 2HB/W and TAV of the fused fabrics according to the types of face fabric, interlining, fusing temperature. Five types of wool fabric, four types of shingosen fabric and four types of interlining were used for this study. The fusing condition in this study were the three types of fusing temperature of 10$0^{\circ}C$, 12$0^{\circ}C$, 14$0^{\circ}C$, the pressure of 4 kgㆍf/$cm^2$, and pressing time of 12 seconds. The results obtained from this study were as follows. 1) The bending rigidities and hysteresis of fabrics after fusing were increased. The bending behavior of fused fabrics were governed by the bending behavior of face fabric and interlinings and $\alpha$$_{B}$ values. 2) The KES standardized basic values of B/W and 2HB/W were increased after fusing. The B/Ws of fused fabrics were mainly determined by the $\alpha$$_{B}$ values of interlinings. The 2HB/Ws of fused fabrics seemed to be controlled by the fusing temperature. 3) The changes of TAVs of wool fused fabrics differed from those of shingosen fused fabrics. As the $\alpha$$_{B}$ values of fabric were larger and fusing temperature were increased, the TAVs of wool fused fabrics were smaller though those of shingosen fused fabrics were larger. 4) The TAVs of fused fabrics were highly correlated with the B/Ws of fused fabrics. In the case of wool fused fabrics, the TAVs of fused fabrics were negativly correlated with the 2HB/Ws of wool fabrics and used interlinings.nings.

  • PDF

A Study on the Growing Characteristics of Dendrite Structure of Melted Wire Deteriorated by Over Current (과전류 열화에 의해 용단된 전선의 수지상 조직 성장특성에 관한 연구)

  • Shong, Kil-Mok;Choi, Chung-Seog;Kim, Dong-Woo;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1463-1465
    • /
    • 2003
  • In this paper, we studied on the growing characteristics of dendrite structure of melted wire deteriorated by over current. Electric wire was melted by Jolue's heat. By using HSIS(High Speed Imaging System), we found out a lot of melted parts of wire were dispersed and radiated. Electric wire had narrow melted areas in case of short fusing time. A lot of very small dots generated around the grain of copper cross-section and they were changed into dendrite structure. Dendrite structure appeared at the values lower than 2.5[A/sec]. In case of very short fusing time, fusing current was calculated by empirical formula. The Preece equation was not enough to analyze a variety of characteristics of melted wire because it did not consider melting time, atmosphere, etc.

  • PDF

The Characteristics of Arc Scattering and Fusing Current of Copper Wire in the Fault Process DB System of Cables in a PL Environment

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.52-58
    • /
    • 2008
  • The importance of. identifying the causes of electrical faults cannot be overstated because of the accidents caused by over-current that take place at the home, the office and electrical facilities due to misuse, poor products and system faults. It is necessary to gather objective, scientific data pertaining to electrical fault investigation in a product liability(PL) environment. To date, no database(DB) has been built concerning the accurate cause analysis of faultyfacilities. In this paper, accident hazard and arc scattering when over-current flows in copper wire was investigated. It was found that when over-current flows in a copper wire, the copper wire became heated and bent and beads were scattered around the wire with a flash. It was determinedthat the fusing current and time was related to the current rise per second. For example, when the current rise per second was largethe fusing current was higher than when the current rise per second was small, and the beads dispersed along a wide area. Fusing time, however, was shorter. The possibility of electrical fault became highest when the fusing current was higher. As the current rise per second is short, the dendrite structure is distributed in the surface of the copper wire. These experimental results can be utilized for a fault process DB system in the investigation and the prevention of electrical faults.