• 제목/요약/키워드: Fused silica glass

검색결과 30건 처리시간 0.047초

Femtosecond Laser Application to Optical Memory and Microfluidics

  • Sohn Ik-Bu;Lee Man-Seop;Woo Jeong-Sik;Lee Sang-Man;Chung Jeong-Yong
    • Journal of the Optical Society of Korea
    • /
    • 제9권3호
    • /
    • pp.92-94
    • /
    • 2005
  • We present a novel method for three-dimensional optical memory and microchannel embedded in fused silica glass. Three-dimensional dot patterning with a femtosecond laser pulse and observation with optical microscope are performed. Dot patterns are created by use of a 0.42 N.A. objective to focus 100 fs laser pulses inside the material. We demonstrate data storage with $2{\mu}m$ dot pitch and $7{\mu}m$layer spacing $(36 Gbit/cm^3)$. A three-dimensional microchannel acting as microfluidic and microoptical components is directly fabricated inside a silica glass. The optical micrographs of the microchannel are obtained by a digital camera of a microscope.

무편광 Hybrid Sol-Gel 배열도파로 격자 소자의 설계 및 제작 (Polarization-Insensitive Design and Fabrication of Hybrid Sol-Gel Arrayed Waveguide Gratings)

  • 박순룡;정재완;오범환;이승걸;이일항
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.105-108
    • /
    • 2002
  • We report on the polarization-insensitive design and fabrication of an arrayed waveguide gratings (AWG's) using sol-gel derived silica glass films formed on fused silica substrates to provide cheap and stable tools for better design. An arrayed-waveguide grating multiplexer with raised structure is fabricated in order to effect polarization sensitivity. Since polarization is usually not known after propagation in an optical fiber. passive WDM components such as monolithic wavelength demultiplexer have to be polarization insensitive. Here, we observed that polarization have effect on crosstalk of output spectrum in arrayed-waveguide grating

  • PDF

전기 분무 이온화를 이용한 단백질 질량분석용 마이크로 유체 소자의 제작 및 실험 (Sheathless electrospray ionization with integrated metal emitter on microfluidic device)

  • 김민수;주황수;이국녕;김병기;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2102-2104
    • /
    • 2004
  • In this study, sheathless electrospray from PDMS/glass microchips with conducting metal emitter tip is described. A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system has advantages of the CE separation and on-line electrospray detection of peptide solution. We have fabricated a new electrospray ionization(ESI) device composed of the metal emitter tip and CE separation channel monolithically in a glass microchip. The separation channel and metal emitter tip are fabricated using a glass wet etching and gold electro plating process, respectively. The fabricated micro electrospray chip was tested by spraying peptide sample for mass spectrometric analysis. Singlely-charged peak and doublely-charged peak of peptide were detected and further MS/MS fragmentation was performed in each peak. Direct comparisons with conventional glass or fused silica emitters showed very similar performance with respect to signal strength and stability.

  • PDF

Effects of ceramic fillers on fracture resistance of barrier ribs of PDP

  • Baek, Se-Kyung;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.552-554
    • /
    • 2004
  • Barrier ribs of plasma display panel (PDP) are glass matrix composite reinforced with alumina particles. Mechanical properties of the ribs are very crucial for the improvement in reliability of the panel as the ribs might fracture during transportation and service. In this study, therefore, the effects of filler type and content on the mechanical properties of the ribs were investigated. The fillers used include $Al_2O_3$, $TiO_2$, $ZrO_2$ and fused silica. The content of the filler was changed from 0 to 40 vol.%. The mechanical properties of the ribs measured were hardness, Young's modulus, fracture toughness, and 3-point bending modulus. The fracture toughness evaluated by micro-Vicker's indentation of the composites, in general, was measured to increase with the content of the filler until the sintered density does not decrease significantly. The improvement, however, was dependent on the type of filler employed.

  • PDF

펨토초 레이저를 이용한 미세 패터닝 기술 (Periodic patterning using a femtosecond laser)

  • 손익부;이만섭;우정식;이상만;정정용
    • 한국레이저가공학회지
    • /
    • 제8권1호
    • /
    • pp.39-44
    • /
    • 2005
  • We report experimental results on the periodic patterning using a Ti:sapphire femtosecond laser (800nm, 100fs, 1kHz). Periodic structures with reproducible basic patterns are produced both on the surface and inside transparent materials. Period patterning for the application to display panel is widely investigated. Also, the submicron dot and line patterns are fabricated inside fused silica glass, which is important for the formation of diffraction grating in integrated optical circuit. finally, we demonstrate the utility of the femtosecond laser application to optical memory by fabricating the three-dimensional dot patterns.

  • PDF

레이저를 이용한 회절격자 제작 및 효율 향상 연구 (Fabrication and improvement of diffraction grating with femtosecond and $CO_2$ laser)

  • 최훈국;손익부;노영철;김진태
    • 한국레이저가공학회지
    • /
    • 제15권2호
    • /
    • pp.6-10
    • /
    • 2012
  • We fabricated the diffraction grating on the surface of fused silica glass using a femtosecond laser. The grooves of diffraction grating has a lot of micro crack and debris result in reduced diffraction efficiency. So, we polished the diffraction grating with $CO_2$ laser beam. With different scan number of $CO_2$ laser beam, we observed the image of diffraction grating and measured the diffraction efficiency.

  • PDF

Femtosecond Micromachining Applications for Optical Devices

  • Sohn, Ik-Bu;Lee, Man-Seop;Woo, Jeong-Sik
    • Journal of the Optical Society of Korea
    • /
    • 제8권3호
    • /
    • pp.127-131
    • /
    • 2004
  • This paper investigates applications of femtosecond lasers for the micromachining of transparent materials and fabrication of optical devices. We show commercial micromachining examples of transparent materials which have been fabricated for various applications. Near infrared femtosecond laser processing is an attractive method to fabricate three-dimensional optical waveguides into various transparent materials. Focused femtosecond laser pulses induce a permanent refractive-index change only near the focal point. We also demonstrate a Y coupler with the splitting ratio of 1:1 written by femtosecond laser pulses into a fused silica glass. The minimum propagation loss of 0.8 ㏈/㎝ awl the refractive-index change of 0.006-0.01 at the wavelength of 1550 ㎚ were achieved by optimization of the laser fluence.

Femtosecond Laser Application to PLC Optical Devices and Packaging

  • Sohn, Ik-Bu;Lee, Man-Seop;Lee, Sang-Man
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.446-448
    • /
    • 2005
  • Using tightly focused femtosecond laser pulses, we produce an optical waveguide and devices in transparent materials. This technique has the potential to generate not only channel waveguides, but also three-dimensional optical devices. In this paper, an optical splitter and U-grooves, which are used for fiber alignment, are simultaneously fabricated in a fused silica glass using near-IR femtosecond laser pulses. The fiber- aligned optical splitter has a low insertion loss, less than 4 dB, including an intrinsic splitting loss of 3 dB and excess loss due to the passive alignment of a single-mode fiber. Finally, we present an output field pattern, demonstrating that the splitting ratio of the optical splitter becomes approximately 1:1.

  • PDF

표면 미세 가공기술을 이용한 마이크로 캔틸레버의 제작과 바이오센서로의 응용 (Fabrication of Microcantilever-based Biosensor Using the Surface Micromachining Technique)

  • 유경아;정승룡;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.11-15
    • /
    • 2006
  • We propose an optical and an electrical detection methods for detecting various bio-molecules effectively with microcantilevers. The microcantilevers were fabricated employing surface micromachining technique that has attractive advantages in terms of cost efficiency, simplicity and ability of fabricating in array. The fluid cell system for injection of bio-molecular solution is fabricated using polydimethylsiloxane (PDMS) and a fused silica glass. The microcantilever is deflected with respect to the difference of the surface stress caused by the formation of self-assembled bio-molecules on the gold coated side of the microcantilever. It detected cystamine dihydrochloride and glutaraldehyde molecules and analyzed individual concentrations of the cystamine dihydrochloride solution. We confirm that the deflections of bending-up or bending-down are occurred by the bio-molecule adsorption and microcantilever can be widely used to a ${\mu}-TAS$ and a lab-on-a-chip for a potential detection of various bio-molecules.