• 제목/요약/키워드: Fuse elements

검색결과 40건 처리시간 0.019초

정밀 다층 박막 도금을 이용한 빠른 동작 퓨즈 특성 설계 (Design of Fast Acting Fuse Characteristics Using a Precision Multi-layer Thin Film Plating)

  • 김은민;강창룡
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.445-451
    • /
    • 2016
  • General fuse elements of solution for fast acting operation characteristics made using silver or silver alloy, those are not able to dominate cost competition to the advanced global leaders that have not only high technology but competitive price. In this study, the method that compose the fuse elements manufactured solution of fast acting operation characteristics by using precision multi-layer thin film plating and helical cutting process from low-priced copper metal. Furthermore, in order to move rated current line of fuse due to the heat loses, the manufacture construction method of fixed resistor is introduced, and then Ni-P plating layer and Sn plating layer are introduced multiply for controling fine opening time characteristics. So this study can establish the high productive and low-priced production method.

높은 차단용량 특성을 갖는 초소형 미니어처 퓨즈의 가용체 설계 (Design for a Fuse Element of Sub-miniature Fuse with High Breaking Capacity Characteristics)

  • 안창환
    • 전자공학회논문지
    • /
    • 제54권3호
    • /
    • pp.131-137
    • /
    • 2017
  • 네트워크 기반의 휴대용 전자 제품의 시장 성장으로 전기기기들은 더욱 소형화 되고 있는 추세이고 내부 부품간의 거리가 가까워져 회로 단락의 위험이 높아지고 있다. 회로의 단락 상황에서 유입되는 높은 과전류로 부터 폭발이나 화재 없이 전자기기를 안전하게 보호하기 위해서는 차단용량이 높은 밀폐형 카트리지 퓨즈를 적용해야 하지만 제품의 소형화 추세에 따른 공간의 문제로 해당 퓨즈의 적용이 불가능한 실정이다. 이를 해결하기 위해서 화학적 결합으로 퓨즈 가용체를 보호하는 밀폐형 퓨즈보다 공기의 유입이 자유로울 뿐만 아니라 물리적 결합으로 퓨즈링크를 보호하는 반밀폐형 초소형 퓨즈가 적용되는 것이 적합하지만 높은 차단용량 특성을 구현하는데 한계가 있다. 이에 본 논문에서는 상대적으로 공간을 적게 차지하면서 높은 차단용량을 갖는 반밀폐형 초소형 퓨즈를 위한 퓨즈 가용체 합금과 퓨즈링크의 설계 기술을 통하여 회로의 단락 상황에서 안전성을 확보하였다.

휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계 (Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System)

  • 강창룡;김은민
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

반도체 보호용 휴즈의 열화특성에 관한 연구 (A study on the Aging Properties of semiconductor Fuse-Link)

  • 이세현;이병성;정석조;한상옥;성기선;김종석;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.52-54
    • /
    • 1993
  • A new type of semiconductor fuse-link with fuse elements deposited on ceramic substrate introduced. The construction and aging property of this fuse-link, as well as the test circuitry built especially for the development of this fuse-link explained below.

  • PDF

대용량 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 저융점 금속 가용체 설계 (Design of Low-Melting Metal Fuse Elements of Current Sensing Type Protection Device for Large Capacity Secondary Battery Protection System)

  • 김은민;강창룡
    • 한국전기전자재료학회논문지
    • /
    • 제31권6호
    • /
    • pp.427-432
    • /
    • 2018
  • High-capacity secondary batteries can cause explosion hazards owing to microcurrent variations or current surges that occur in short circuits. Consequently, complete safety cannot be achieved with general protection that is limited to a mere current fuse. Hence, in the case of secondary batteries, it is necessary for the protector to limit the inrush current in a short circuit, and to detect the current during microcurrent variations. To serve this purpose, a fuse can be employed for the secondary battery protection circuit with current detection. This study aims at designing a protection device that can stably operate in the hazardous circumstances associated with high-capacity secondary batteries. To achieve the said objective, a detecting fuse was designed from an alloy of low melting point elements for securing stability in abnormal current states. Experimental results show that the operating I-T and V-T characteristic constraints can be satisfied by employing the proposed current detecting self-contained low melting point fuse, and through the resistance of the heating resistor. These results thus verify that the proposed protection device can prevent the hazards of short circuit current surges and microcurrent variations of secondary batteries.

고성능 유압 휴즈의 특성에 관한 연구 (A practical study of a quick-acting hydraulic fuse)

  • 이성래
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.939-944
    • /
    • 1991
  • The dynamic behavior of a quick-acting hydraulic fuse is investigated by analysis and experiment. In view of the short response time, a proper dynamic analysis of the entire hydraulic circuit is necessary, in addition to analysis of the fuse behavior. Dynamic models of the fuse and other hydraulic circuit elements used in the experimental setup are derived and used for computer simulation. Also, the experiments are performed under a variety of operating conditions. Experimental and analytical results are in very good agreement.

  • PDF

Performance of innovative composite buckling-restrained fuse for concentrically braced frames under cyclic loading

  • Mohammadi, Masoud;Kafi, Mohammad A.;Kheyroddin, Ali;Ronagh, Hamid R.
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.163-177
    • /
    • 2020
  • Concentrically Braced Frames (CBFs) are commonly used in the construction of steel structures because of their ease of implementation, rigidity, low lateral displacement, and cost-effectiveness. However, the principal disadvantage of this kind of braced frame is the inability to provide deformation capacity (ductility) and buckling of bracing elements before yielding. This paper aims to present a novel Composite Buckling Restrained Fuse (CBRF) to be utilized as a bracing segment in concentrically braced frames that allows higher ductility and removes premature buckling. The proposed CBRF with relatively small dimensions is an enhancement on the Reduced Length Buckling Restrained Braces (RL-BRBs), consists of steel core and additional tensile elements embedded in a concrete encasement. Employing tensile elements in this composite fuse with a new configuration enhances the energy dissipation efficiency and removes the tensile strength limitations that exist in bracing elements that contain RL-BRBs. Here, the optimal length of the CBRF is computed by considering the anticipated strain demand and the low-cyclic fatigue life of the core under standard loading protocol. An experimental program is conducted to explore the seismic behavior of the suggested CBRF compare with an RL-BRB specimen under gradually increased cyclic loading. Moreover, Hysteretic responses of the specimens are evaluated to calculate the design parameters such as energy dissipation potential, strength adjustment factors, and equivalent viscous damping. The findings show that the suggested fuse possess a ductile behavior with high energy absorption and sufficient resistance and a reasonably stable hysteresis response under compression and tension.

반밀폐형 퓨즈의 차단용량 상승을 위한 Fe-Ni 합금 가용체의 형상 및 퓨즈링크 구조 설계 (Design of Fuse-Link Structure & Fe-Ni Alloy Element's Shape to Increase an Interrupt Rating of a Semi-Enclosed Type Fuse)

  • 김성주;김도훈;강창룡
    • 전기학회논문지
    • /
    • 제67권5호
    • /
    • pp.644-650
    • /
    • 2018
  • According to a miniaturization and integration of electric device, a little size of fuse satisfying the current carrying capacity as well as an explosive tolerance and current interrupt rating are required. Fe-Ni alloy is applied to decrease an oxidation of fuse elements. A resistance and T.C.R(temperature coefficient of resistance) of a fuse are analyzed by changing a content of Ni And full rated current I-T curve from 1A to 6.3A has been tested. In order to an explosive energy, a straight wire type is selected to reduce a fuse melting time. An interrupt rating test was conducted by changing a content of Ni and the optimal content of Ni is to be 40%.

휴즈 엘리먼트 노치 형태에 따른 차단특성에 관한 연구 (A Study on the Breaking Phenomena Varying with Notch Shape of Fuse-Element)

  • 이병성;이세현;이종칠;박구범;한상옥;김종석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1382-1384
    • /
    • 1994
  • Description is given of the effect of fuse-element notch shape on interruption parameters. The notch of fuse-elements have all the same area. Tests were carried out at direct current and carried out the effect of the fuse element construction on the process of interrupting short circuit and overload current. The arcing phenomenon in a low voltage fuse operation in case of high current value of short circuit is analyzed.

  • PDF

세라믹 기판을 이용한 반도체 보호용 휴즈 엘리먼트에 관한 연구 (A Study on the fuse elements for the protection of a semiconductor using a ceramic substrate)

  • 이세현;한상옥;김종석;이신현;성기선;권영훈;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.762-764
    • /
    • 1992
  • This Paper presents some experimental result of current limiting and short circuit interruption behavior of thin copper film, 12${\mu}m$, 25${\mu}m$, 40${\mu}m$, 50${\mu}m$ on alumina substrate. and a fuse-link having elements of copper film provided with high-precision small hols with electrolytical process. Construction, fabrication, as well as the test circuitry built especially for the develoment of this fuse-links are explained below.

  • PDF