• Title/Summary/Keyword: Fundamental performance

Search Result 1,778, Processing Time 0.025 seconds

The Influence of Learning Self-efficacy, Confidence in Performance of Fundamental Nursing Skills and Satisfaction with Practicum on Nursing Students' Satisfaction in major (간호대학생의 학습 자기효능감, 기본간호술수행자신감 및 실습만족도가 전공만족도에 미치는 영향)

  • Lee, Hyunsook Zin;Ahn, Sung Mi
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.251-262
    • /
    • 2020
  • The study was conducted to investigate factors influencing satisfaction in major on nursing students. A convenience sample 159 nursing student was selected from G do and C do, between 17 June and 24 June 2019. Data were analyzed t-test, one-way ANOVA, Pearson's correlation, and multiple regression analysis. Factors that influenced satisfaction in major included gender, age, religion, perceived academic achievement, acquisition of fundamental nursing skills(FNS), perceived health state. Satisfaction in major showed a positive correlation with learning self-efficacy(LSE), confidence in performance of FNS and satisfaction with practicum. These variables revealed regression analysis that significant factor and explained 63.0% of the variance. It is necessary to develop and test programs to ensure an improvement in LSE, confidence in performance of FNS and satisfaction with practicum among nursing students to increase their satisfaction in major.

A Study on the Fundamental Properties of High-Strength Concrete Using Ground Granulated Blast-Furnace Slag as an Admixture (고로슬래그 분말을 혼화재로 사용한 고강도콘크리트의 기초적 성질에 대한 연구)

  • 문한영;최연왕;문대중;송용규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.30-35
    • /
    • 1995
  • This paper presents fundamental experiment for the properties of high performance concrete in its fresh and hardened state made with ground granulated blast-furnace (GGBF) slag. The result is that the effect of decreasing xoncrete temperature is to the mixing ratio of GGBF slag, but it presents disadvantage in the slump loss phase. In addition to, we know that the splitting tensile strength, compressive strength and elastic modulus of concrete mixed with high fineness GGBF slag are increased at age 28days.

  • PDF

Performance-Based Seismic Design (내진설계의 성능 기준화)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.4-10
    • /
    • 1997
  • The fundamental philosophy underlying the seismic design of structures and systems are evolving into the performance based concept. The background and current status of this development in other countries are briefly summarized. The new code system which consists of two level seismic design criteria will be introduced. The implementation of the preformance based design concepts in the criteria will be explained.

  • PDF

Extracting Predominant Melody from Polyphonic Music using Harmonic Structure (하모닉 구조를 이용한 다성 음악의 주요 멜로디 검출)

  • Yoon, Jea-Yul;Lee, Seok-Pil;Seo, Kyeung-Hak;Park, Ho-Chong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.109-116
    • /
    • 2010
  • In this paper, we propose a method for extracting predominant melody of polyphonic music based on harmonic structure. Since polyphonic music contains multiple sound sources, the process of melody detection consists of extraction of multiple fundamental frequencies and determination of predominant melody using those fundamental frequencies. Harmonic structure is an important feature parameter of monophonic signal that has spectral peaks at the integer multiples of its fundamental frequency. We extract all fundamental frequency candidates contained in the polyphonic signal by verifying the required condition of harmonic structure. Then, we combine those harmonic peaks corresponding to each extracted fundamental frequency and assign a rank to each after calculating its harmonic average energy. We finally run pitch tracking based on the rank of extracted fundamental frequency and continuity of fundamental frequency, and determine the predominant melody. We measure the performance of proposed method using ADC 2004 DB and 100 Korean pop songs in terms of MIREX 2005 evaluation metrics, and pitch accuracy of 90.42% is obtained.

The Effects of Business strategy on Business performance -IT applicability with parameter and regulation effect- (경영전략이 경영성과에 미치는 영향 -정보기술 활용도를 매개와 조절효과 중심으로-)

  • Kong, Seok-Jin;Yang, Hae-Sool
    • Journal of Digital Convergence
    • /
    • v.12 no.1
    • /
    • pp.177-192
    • /
    • 2014
  • In this study, To identify the member of an organization can be affected use of information technology and support of information technology how business strategy affected business performance. Also, This study is considered to be the epitome of corporate strategy in the Miles & Snow of the 'adaptation strategy' and Michael E. Porter of the 'fundamental competitive strategy' at the same time, by applying the existing business management strategy that can be applied to target compared to the type of management performance measures are presented for the purpose. the results of the study can be summarized as follows. First, Business strategies affect the financial performance for the hypothesis that Miles & Snow of the 'adaptation strategy' honor type of defensive strategy and financial performance and strategy management and positive impact on non-financial performance was found. Second, Management strategies affect the financial performance for the hypothesis that Michael E. Porter of the 'fundamental competitive strategies' overall cost leadership strategy and differentiation strategy of management and financial performance and non-financial performance was found to positively impact. Also, Business performance management strategy significantly positive affect, Business strategies with the characteristics of the relationship between management and Information technology utilization showed that the moderating effects.

A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions (비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법)

  • Khan, Reyyan Ahmad;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.231-239
    • /
    • 2018
  • The phase-locked loop (PLL) is widely used in grid-tie inverter applications to achieve a synchronization between the inverter and the grid. However, its performance deteriorates when the grid voltage is not purely sinusoidal due to the harmonics and the frequency deviation. Therefore, a high-performance PLL must be designed for single-phase inverter applications to guarantee the quality of the inverter output. This paper proposes a simple method that can improve the performance of the PLL for the single-phase inverter under a non-sinusoidal grid voltage condition. The proposed PLL can accurately estimate the fundamental frequency and theta component of the grid voltage even in the presence of harmonic components. In addition, its transient response is fast enough to track a grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions (비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.7-8
    • /
    • 2017
  • The Phase-Locked Loop (PLL) is widely used in grid-tie inverter applications to achieve the synchronization between the inverter and the grid. However, its performance is deteriorated when the grid voltage is not pure sinusoidal due to the harmonics and the frequency deviation. Therefore it is important to design a high performance phase-locked loop (PLL) for the single phase inverter applications to guarantee the quality of the inverter output. In this paper a simple method to improve the performance of the PLL for the single phase inverter is proposed. The proposed PLL is able to accurately estimate the fundamental frequency component of the grid voltage even in the presence of harmonic components. In additional its transient response is fast enough to track a change in grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

  • PDF

Upgrading equivalent static method of seismic designs to performance-based procedure

  • Allahvirdizadeh, Reza;Mohammadi, Mohammad Ali
    • Earthquakes and Structures
    • /
    • v.10 no.4
    • /
    • pp.849-865
    • /
    • 2016
  • Beside the invaluable advancements in constructing more secure buildings, the post-earthquake inspections have reported considerable damages. In other words, the modern buildings satisfactorily decrease fatalities but the monetary impacts still mostly remain an unsolved concern of the stakeholders, the insurance companies and society together. Therefore, the fundamental target of the researches shifted from current force-based seismic design regulations to the Performance-Based earthquake engineering (PBEE). At the moment, some probabilistic approaches, such as PEER framework have been developed to predict the performance of building at any desired hazard levels. These procedures are so time-consuming, to which many details are needed to be assigned. It causes their usage to be limited. On that account, developing more straightforward methods seems indispensable. The main objective of the present paper is to adapt an equivalent static method in different damage states. Consequently, constant damage spectrums corresponding to different limit states, soil types, ductility and fundamental periods are plotted and tri-linear formulas are proposed for further applications. Moreover, the sensitivity of outcomes to the employed hysteresis model, ductility, viscous damping and site soil type is investigated. Finally, a case study building with moment-resisting R.C. frame is evaluated based on the both of new and current methods to ensure applicability of the proposed method.

Inelastic seismic response of adjacent buildings linked by fluid dampers

  • Xu, Y.L.;Yang, Z.;Lu, X.L.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.5
    • /
    • pp.513-534
    • /
    • 2003
  • Using fluid dampers to connect adjacent buildings for enhancing their seismic resistant performance has been recently investigated but limited to linear elastic adjacent buildings only. This paper presents a study of inelastic seismic response of adjacent buildings linked by fluid dampers. A nonlinear finite element planar model using plastic beam element is first constructed to simulate two steel frames connected by fluid dampers. Computed linear elastic seismic responses of the two steel frames with and without fluid dampers under moderate seismic events are then compared with the experimental results obtained from shaking table tests. Finally, elastic-plastic seismic responses of the two steel frames with and without fluid dampers are extensively computed, and the fluid damper performance on controlling inelastic seismic response of the two steel frames is assessed. The effects of the fundamental frequency ratio and structural damping ratio of the two steel frames on the damper performance are also examined. The results show that not only in linear elastic stage but also in inelastic stage, the seismic resistant performance of the two steel frames of different fundamental frequencies can be significantly enhanced if they are properly linked by fluid dampers of appropriate parameters.

Improving Low Frequency Signal Reproduction in TV Audio (TV 스피커의 저주파수 신호 재생 개선)

  • Arora Manish;Oh Yoonhark;Kim SeoungHun;Lee Hyuckjae;Jang Seongcheol
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.275-278
    • /
    • 2004
  • In TV sound system, loudspeakers are subject to severe size constraints. The small size of the transducer affects the low frequency signal performance of the system. Bass signal performance contributes significantly to the user perceived sound quality and a good bass signal reproduction is essential. Increasing the sound energy in the bass signal range is an unviable solution since the gain required are exceedingly high and signal distortion occurs because of the speaker overload. Recently methods are being proposed to invoke low frequency illusion using psychoacoustic phenomena of the missing fundamental. This paper proposes a simple and effective signal processing method to create bass signal illusion in TV speakers using the missing fundamental effect, at a complexity of 12 MIPS on Motorola 56371 audio DSP.

  • PDF