• Title/Summary/Keyword: Fundamental mass Concrete

Search Result 38, Processing Time 0.022 seconds

Fundamental characteristics of Normal Strength Concrete According to the Changes of AE Agent Pre-addition Volume to ERCO of Mixed after completion (비빔완료 후 즉시 혼입한 ERCO에 AE제 사전혼입량 변화에 따른 보통강도 콘크리트의 기초적 특성)

  • Kim, Tae-Woo;Lee, Hyuk-Ju;Kim, Jong;Jeon, Chung-Keon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.206-207
    • /
    • 2018
  • This study is a series of studies intended to derive the improvement of strength concrete quality using an emulsified refined oil (ERCO). In other words, ERCO is used to analyze the improvement degree of the basic properties of ordinary strength concrete by pre-adding the AE Agent on its products. ERCO was also planned to have a mixing ratio of 0, 0.5 %, and the pre-addtion of AE agent mixed with 0, 1, 2, and 3 % of the concrete's mixed ERCO mass. As a result, as the pre-injection of AE agent was increased, the slump, and air contents tended to be improved microscopically, but there was no significant effect. and Compressive strength tends to increase smart-all as the pre-addtion of AE agent increases in concrete, but it does not have a significant effect.

  • PDF

Permanent Sprayed Concrete Tunnel Linings Waterproofed with Bonded Membranes. A Review of the Current State-of-the-art for Hard Rock Conditions

  • Holter, K.G.
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.21 no.2
    • /
    • pp.103-116
    • /
    • 2019
  • Permanent sprayed concrete tunnel linings waterproofed with bonded membranes have been used at a number of important traffic projects over the last decade. Research has been carried out in several teams in order to increase the understanding of the function, properties and behavior of such linings under different loading and boundary conditions. The basic layout of this lining gives fundamental different system properties compared to the traditional lining systems. The main differences pertain to the groundwater exposure and the resulting hydraulic loading, the response of the concrete and membrane materials to this loading, as well as the geomechanically induced loading of the lining structure. The current understanding of the function and properties of such lining structures is presented in the paper based on review of recent research carried out in Norway, as well as field observations and monitoring carried over a several years. The influence of the water exposure on the final condition of the concrete and membrane materials has proven to be of vital importance for proper material testing and acceptance, assessments of the mechanical contribution of the bonded membrane, as well as assessments of the longterm durability of such linings. Obtaining realistic material parameters for the concrete and membrane materials subject to the boundary conditions posed by the groundwater exposure in an undrained structure is emphasized. Finally, some recent results from currently ongoing research on such linings, particularly the hydraulic response of the rock mass and the long term behavior of the concrete and membrane materials are presented.

An Experimental Study on the Corrosion Characteristics of Reinforcement Concrete According to Types of Surface Covering Material (표면피복재 종류에 따른 철근콘크리트의 철근 부식특성에 관한 실험적 연구)

  • 김갑수;장종호;김재환;김용로;오시덕;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.39-43
    • /
    • 2003
  • Chloride ions are considered to be the major cause of steel corrosion in concrete structures exposed to seashore environments and also permeation of chloride is controlled by chloride diffusion. Therefore, the study on chloride diffusion of concrete have been done so far by many researchers. It is reported that coating material as surface covering material is effect about deterioration of salt damage and carbonation, therefore these materials are important in durability of concrete structure. In this study, corrosion characteristics of reinforcement concrete according to types of surface covering material were evaluated by water-cement ratio, chloride penetration by age on the corrosion area rate and mass decrement of reinforcement. And it is considered that the result of this study on application of the corrosion characteristics of reinforcements under salt damage environmental will be suggested as fundamental data of control performance of salt damage. It is performed that comparison and examination of control performance of salt damage by the corrosion characteristics under salt damage environmental.

  • PDF

Forced Vibration Testing of a Four-Story Reinforced Concrete Frame Building (철근콘크리트조 4층 골조건물의 강제진동실험)

  • Yu, Eun-Jong;Wallace, John W.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.27-38
    • /
    • 2007
  • A series of forced vibration tests and ambient vibration measurement was conducted on a four-story reinforced concrete building damaged in the 1994 Northridge earthquake. Both low amplitude broadband and moderate amplitude harmonic excitation were applied using a linear shaker and two eccentric mass shakers, respectively, and ambient vibrations were measured before and after each forced vibration test. Accelerations, interstory displacements, and curvature distributions were monitored using accelerometers, LVDTs and concrete strain gauges. Natural frequencies and the associated mode shapes fur the first 7 modes were identified. Fundamental frequencies determined from the eccentric mass shaker tests were 70% to 75% of the values determined using ambient vibration data, and 92% to 93% of the values determined using the linear shaker test data. Larger frequency drops were observed in the NS direction of the building, apparently due to damage that was induced during the Northridge earthquake.

Physical Properties of Lightweight and Normal Weight Concretes due to Water-Cement Ratio Changes (물-시멘트비 변화에 따른 경량콘크리트와 일반콘크리트의 물리적 성질)

  • Lee, Chang-Soo;Kim, Jae-Nam;Lim, Youn;Ma, Moon-Hak
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.4
    • /
    • pp.11-20
    • /
    • 2009
  • By using the artificial lightweight aggregate for the natural aggregate depletes and destruction of environment and the application of lightweight concrete in structure, the lightweight concrete is manufactured. The fundamental characteristics by the waterbinder ratio was evaluated. It is suggested the method to control of pre-absorbed water of the lightweight aggregate. Lightweight concrete with pre-absorbed aggregate has similar characteristics compared to normal weight concrete regardless of water-binder ratio. According to the water-binder ratio, the drying condition, and the rebar, the unit mass of the lightweight concrete showed the reduction of 14.6${\sim}$21.0% as the range of 1,668${\sim}$1,998 $kg/m^3$ in comparison to the normal weight concrete. The lightweight aggregate pre-absorbed water showed the deferent evaporation quantity according to the water-binder ratio. As the water-binder ratio is lower, the oven dry vapour water is larger, therefore the internal curing water is increasing. In the same water-binder, comparing the normal concrete the lightweight concrete shows lower compressive strength which is due to the different strength of an aggregate. In the air dry curing, the normal weight concrete has a lower strength improvement effect in w/c 0.3 than the ratio 0.4 and 0.5. However, the strength improvement effect has increasing as the water-binder ratio was low in the light concrete.

Fundamental Research on Reactivity of Silica Source in the Rapidly Cured Inorganic Micro-Defect-Free(MiDF) Concrete (촉진 양생한 무기계 MiDF 콘크리트에서 실리카질 원료의 반응성에 관한 기초 연구)

  • Choi, Hong-Beom;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.2
    • /
    • pp.166-173
    • /
    • 2019
  • In this paper, the reaction properties of silica source in the accelerated curing conditions using autoclave and the fundamental properties of inorganic Micro Defect Free(MiDF) concrete using silica source are studied. Studies show that Si ions elution rate from silica source in autoclave curing is higher in amorphous source. In tap water conditions, solids which is source after autoclaved curing show a higher mass reduction in amorphous materials, which is attributed to the higher elution rate of ion. In $Ca(OH)_2$ solution conditions, amorphous materials show higher mass increase, due to increase in C-S-H minerals. From experiment for influence on the properties of MiDF concrete by using nano silica materials, the specimen with silica fume shows an increase in compressive strength and a decrease in absorption depending on replacement rate up to 5.5%, while nano silica with amorphous phase and high-fineness shows a decrease in compressive strength and decrease in the water absorption. The specimen with nano silica increases the pore below 10,000nm, but reduces pore between 10,000 and 100,000nm. The above results show that the porosity and absorption rate of MiDF concrete can be reduced by using amorphous nano-size silica. However, to reduce the pore of 50 to 10,000nm, better dispersion of nano material in the cement matrix will be necessary. We will focus on the this item in the next research.

Computing input energy response of MDOF systems to actual ground motions based on modal contributions

  • Ucar, Taner
    • Earthquakes and Structures
    • /
    • v.18 no.2
    • /
    • pp.263-273
    • /
    • 2020
  • The use of energy concepts in seismic analysis and design of structures requires the understanding of the input energy response of multi-degree-of-freedom (MDOF) systems subjected to strong ground motions. For design purposes and non-time consuming analysis, however, it would be beneficial to associate the input energy response of MDOF systems with those of single-degree-of-freedom (SDOF) systems. In this paper, the theoretical formulation of energy input to MDOF systems is developed on the basis that only a particular portion of the total mass distributed among floor levels is effective in the nth-mode response. The input energy response histories of several reinforced concrete frames subjected to a set of eleven horizontal acceleration histories selected from actual recorded events and scaled in time domain are obtained. The contribution of the fundamental mode to the total input energy response of MDOF frames is demonstrated both graphically and numerically. The input energy of the fundamental mode is found to be a good indicator of the total energy input to two-dimensional regular MDOF structures. The numerical results computed by the proposed formulation are verified with relative input energy time histories directly computed from linear time history analysis. Finally, the elastic input energies are compared with those computed from time history analysis of nonlinear MDOF systems.

A review of experimental and numerical investigations about crack propagation

  • Sarfarazi, Vahab;Haeri, Hadi
    • Computers and Concrete
    • /
    • v.18 no.2
    • /
    • pp.235-266
    • /
    • 2016
  • A rock mass containing non-persistent joints can only fail if the joints propagate and coalesce through an intact rock bridge. Shear strength of rock mass containing non-persistent joints is highly affected by the both, mechanical behavior and geometrical configuration of non-persistent joints located in a rock mass. Existence of rock joints and rock bridges are the most important factors complicating mechanical responses of a rock mass to stress loading. The joint-bridge interaction and bridge failure dominates mechanical behavior of jointed rock masses and the stability of rock excavations. The purpose of this review paper is to present techniques, progresses and the likely future development directions in experimental and numerical modelling of a non-persistent joint failure behaviour. Such investigation is essential to study the fundamental failures occurring in a rock bridge, for assessing anticipated and actual performances of the structures built on or in rock masses. This paper is divided into two sections. In the first part, experimental investigations have been represented followed by a summarized numerical modelling. Experimental results showed failure mechanism of a rock bridge under different loading conditions. Also effects of the number of non-persistent joints, angle between joint and a rock bridge, lengths of the rock bridge and the joint were investigated on the rock bridge failure behaviour. Numerical simulation results are used to validate experimental outputs.

Conservation for the Seismic Models of Intake Tower with Nonlinear Behaviors and Fluid Structure Interaction (비선형거동과 구조물유체상호작용을 고려한 취수탑 내진모델의 보수성평가)

  • Lee, Gye-Hee;Lee, Myoung-Kyu;Hong, Kwan-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.17-24
    • /
    • 2020
  • In this study, series of nonlinear seismic analysis were performed on a reinforced concrete intake tower surrounded by water. To consider the fluid effect around the structure, analysis models were composed using an added mass and CEL approach. At this time, the implicit method was used for the added mass model, and the explicit method was used for the fluid structure interaction model. The input motions were scaled to correspond to 500, 1000, and 2400 years return period of the same artificial earthquake. To estimate the counteractivity of the fluid coupled model, models without fluid effect were constructed and used as a reference. The material models of concrete and reinforcement were selected to consider the nonlinear behavior after yielding, and analysis were performed by ABAQUS. As results, in the acceleration response spectrum of the structure, it was found that the influence of the surrounding fluid reducing the peak frequency and magnitude corresponding to the fundamental frequency of the structure. However, the added mass model did not affect the peak value corresponding to the higher mode. The sectional moments were increased significantly in the case of the added mass model than those of the reference model. Especially, this amplification occurred largely for a small-sized earthquake response in which linear behavior is dominant. In the fluid structure interaction model, the sectional moment with a low frequency component amplifies compared to that of the reference model, but the sectional moment with a high requency component was not amplified. Based in these results, it was evaluated that the counteractivity of the additive mass model was greater than that of the fluid structure interaction model.

Application of artificial neural networks for dynamic analysis of building frames

  • Joshi, Shardul G.;Londhe, Shreenivas N.;Kwatra, Naveen
    • Computers and Concrete
    • /
    • v.13 no.6
    • /
    • pp.765-780
    • /
    • 2014
  • Many building codes use the empirical equation to determine fundamental period of vibration where in effect of length, width and the stiffness of the building is not explicitly accounted for. In the present study, ANN models are developed in three categories, varying the number of input parameters in each category. Input parameters are chosen to represent mass, stiffness and geometry of the buildings indirectly. Total numbers of 206 buildings are analyzed out of which, data set of 142 buildings is used to develop these models. It is demonstrated through developed ANN models that geometry of the building and the sizes of the columns are significant parameters in the dynamic analysis of building frames. The testing dataset of these three models is used to obtain the empirical relationship between the height of the building and fundamental period of vibration and compared with the similar equations proposed by other researchers. Experiments are conducted on Mild Steel frames using uniaxial shake table. It is seen that the values obtained through the ANN models are close to the experimental values. The validity of ANN technique is verified by experimental values.