• 제목/요약/키워드: Functional unit

검색결과 773건 처리시간 0.026초

종합병원 병동부 1인 병실 적용에 따른 기능효율성에 관한 연구 - 간호거점에서 병상간의 거리를 중심으로 - (A Study on the Functional Efficiency according to Composition of Single Bedroom in Ward - Focused on Distance from NS to Bed -)

  • 김길채;이현진;권준범
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권2호
    • /
    • pp.17-24
    • /
    • 2015
  • Purpose: This study examines distance from nurse station to bed according to composition of single bedroom. Methods: This study has two groups of target sample ward planes. The first group has diverse patients bedroom. The other group is 36 single bedrooms and 2 3-bedrooms. The guideline of distance measurement was instituted for consistency. This study has 3 main concepts of the guideline. 1) The distance is shortcut from NS to bed. 2) The traffic line is center line between walls and center of door. 3) The start point is center of NS and the end point is bed. Results: The result of this study can be summarized into two points. The first one is that single bedroom has good privacy and longer distance from NS to bed. The second one is that weak point of single bedroom was asked ward operating system and architectural planning like as patients room, bed per unit, location of NS and plan type. Implications: Consideration Should be taken into account for the effective bedroom composition and allocation in ward. This Stuy hopefully serve as a stepping stone for the standard design of space program in ward planning.

유로만곡부(流路彎曲部)의 곡율비(曲率比)와 곡율계수(曲率係數)에 관한 연구(硏究) (A Study on the Curvature Ratio and Coefficient in Channel Bend)

  • 정용태;이진은;송재우
    • 대한토목학회논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1991
  • 운동량방정식을 이용한 하천만곡부 외측제방에 작용하는 단위면적당 수류력은 흐름의 특성, 토사의 특성 및 만곡부의 기하학적 인자의 함수인 곡률계수로 표현할 수 있다. 일반적으로 곡률비가 2.0~4.1인 경우에 외측제방에 작용하는 수류력이 가장크게 나타나는데 한강하류부의 경우 곡률비가 2.0~4.0에 집중된 것은 전구간에서 제방침식을 받게될 가능성이 높을 것으로 사료되어 하천개수계획수립시 필수적으로 고려되어야 하며 철저한 호안공 등의 방법으로 보완되어야 할 것이다. 한편 곡률계수가 최대인 곡률비의 범위가 1963년의 경우 2.21~4.42이고 1981년에는 1.93~3.54이며, 인위적인 하천개 보수공사를 고려한 년간 평균유로이동률이 1967년까지 4.68m/yr이고 1981년까지는 10.48m/yr이다.

  • PDF

Late avulsion of a free flap in a patient with severe psychiatric illness: Establishing a successful salvage strategy

  • Schaffer, Clara;Hart, Andrew;Watfa, William;Raffoul, Wassim;Summa, Pietro Giovanni di
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.589-593
    • /
    • 2019
  • Post-traumatic defects of the distal third of the leg often require skipping a few steps of the well-established reconstructive ladder, due to the limited local reliable reconstructive options. In rare cases, the reconstructive plan and flap choice may encounter challenges when the patient has psychiatric illness affecting compliance with postoperative care. We describe a case of a patient with severe intellectual disability and an open fracture of the distal lower limb. After fracture management and debridement of devitalized tissues, the resultant soft tissue defect was covered with a free gracilis flap. On postoperative day 7, the patient ripped out the newly transplanted flap. The flap was too traumatized for salvage, so a contralateral free gracilis muscle flap was used. The patient showed good aesthetic and functional outcomes at a 1-year follow-up. When planning the postoperative management of patients with psychiatric illness, less complex and more robust procedures may be preferred over a long and complex surgical reconstruction requiring good compliance with postoperative care. The medical team should be aware of the risk of postoperative collapse, focus on the prevention of pain, and be wary of drug interactions. Whenever necessary, free tissue transfer should be performed despite potential compliance issues.

One-Pot Reaction Involving Two Different Amines and Formaldehyde Leading to the Formation of Poly(Macrocyclic) Cu(II) Complexes

  • Lee, Yun-Taek;Kang, Shin-Geol
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권8호
    • /
    • pp.2517-2522
    • /
    • 2012
  • New polynuclear poly(hexaaza macrocyclic) copper(II) complexes $[1](ClO_4)_{2n}{\cdot}(H_2O)_{2n}$, $[2](ClO_4)_{2n}{\cdot}(H_2O)_{2n}$, and $[3](ClO_4)_{2n}{\cdot}(H_2O)_{2n}$ have been prepared by the one-pot reaction of formaldehyde with ethylenediamine and 1,2-bis(2-aminoethoxy)ethane, 1,3-diaminopropane, or 1,6-diaminohexane in the presence of the metal ion. The polymer complexes contain fully saturated 14-membered hexaaza macrocyclic units (1,3,6,8,10,13-hexaazacyclotetradecane) that are linked by $N-(CH_2)_2-O-(CH_2)_2-O-(CH_2)_2-N$, $N-(CH_2)_3-N$, or $N-(CH_2)_6-N$ chains. The mononuclear complex $[Cu(H_2L^5)](ClO_4)_4$ ($H_2L^5$ = a protonated form of $L^5$) bearing two $N-(CH_2)_2-O-(CH_2)_2-O-(CH_2)_2-NH_2$ pendant arms has also been prepared by the metal-directed reaction of ethylenediamine, 1,2-bis(2-aminoethoxy)ethane, and formaldehyde. The polymer complexes were characterized employing elemental analyses, FT-IR and electronic absorption spectra, molar conductance, X-ray diffraction (XRD), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and scanning electron micrograph (SEM). Electronic absorption spectra of the complexes show that each macrocyclic unit of them has square-planar coordination geometry with a 5-6-5-6 chelate ring sequence. The polymer complexes as well as $[Cu(H_2L^5)]^{4+}$ are quite stable even in concentrated $HClO_4$ solutions. Synthesis and characterization of the polynuclear and mononuclear copper(II) complexes are reported.

A 16-channel Neural Stimulator IC with DAC Sharing Scheme for Artificial Retinal Prostheses

  • Seok, Changho;Kim, Hyunho;Im, Seunghyun;Song, Haryong;Lim, Kyomook;Goo, Yong-Sook;Koo, Kyo-In;Cho, Dong-Il;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.658-665
    • /
    • 2014
  • The neural stimulators have been employed to the visual prostheses system based on the functional electrical stimulation (FES). Due to the size limitation of the implantable device, the smaller area of the unit current driver pixel is highly desired for higher resolution current stimulation system. This paper presents a 16-channel compact current-mode neural stimulator IC with digital to analog converter (DAC) sharing scheme for artificial retinal prostheses. The individual pixel circuits in the stimulator IC share a single 6 bit DAC using the sample-and-hold scheme. The DAC sharing scheme enables the simultaneous stimulation on multiple active pixels with a single DAC while maintaining small size and low power. The layout size of the stimulator circuit with the DAC sharing scheme is reduced to be 51.98 %, compared to the conventional scheme. The stimulator IC is designed using standard $0.18{\mu}m$ 1P6M process. The chip size except the I/O cells is $437{\mu}m{\times}501{\mu}m$.

남성 요실금 팬티에 관한 연구 (A Study on Male Panties for Urinary Incontinence)

  • 이정순
    • 한국의상디자인학회지
    • /
    • 제17권1호
    • /
    • pp.39-52
    • /
    • 2015
  • This study aims to analyze the characteristics of the male products for urinary incontinence by examining the types and characteristics of those registered in KIPO (Korean Industrial Property Office). Additionally, the types and characteristics, especially for the cloth products and the pads, of male panties for urinary incontinence on the market are analyzed. Men in their 60s with minor symptoms were selected as the subjects to evaluate the wearability. The results are as follows. 11 male products for urinary incontinence, registered in KIPO, are structurally different from those for women by having a separate pocket mainly for absorption. There are one disposable type and 7 cloth types, and the cloth panties can be classified as either united or separable type depending on the detachability of pads from the panties. The types of the panties vary according to the position, shape, and size of the attached pads on normal male panties (boxer, briefs, drawers). The fabrics for the urinary incontinence are usually piled in 3 to 5 layers by having the most absorptive layer on the top, the next with deodorizing characteristics, and the bottom with the waterproof fabric as basics with some additional layers of antibiotic or breathable fabrics. From the wearability test, it has been determined that the panties are not distinguishable in external appearance and the fitness is also not a problem since the size varies as the normal panties. It has been evaluated that the fitness of the panties is an important factor since the pad should be worn in any form; the pad sewed in the middle of the panties was evaluated to be more wearable than having a long pad. In case of separable panties, when the pattern and fabric is similar to the functional panties and the options such as the thickness of the pads or detachability are given to the users, it tends to be more satisfactory.

  • PDF

아리랑1호 위성 ETB의 전도성 전자파 환경 시험결과 분석 (A Analysis on the Result of CE/CS Test on the KOMPSAT-I ETB)

  • 임성빈;천용식
    • 한국전자파학회논문지
    • /
    • 제12권2호
    • /
    • pp.184-192
    • /
    • 2001
  • 본 논문에서는 아리랑 1호 개발단계에서 위성의 전기/전자적 기능 시험을 수행하기 위해 개발 모델로 구성된 Electrical Test Bed(ETB) 플랫폼에서 수행한 전도성 방출 및 전도성 감응시험 결과를 분석하였다. 전도성 전자파환경시험은 전력공급장지(Power control unit)로부터 위성을 구성하고 있는 각각의 하드웨어와DC 전원을 공급하기 위하여 스위치가 동작하는 순간, 전력 및 신호선을 통하여 전달하게 될 노이즈의 순시 파형을 시간 영역에서 측정하고, 모든 하드웨어에 전력이 공급되어 정상상태로 동작하는 동안에 발생하는 노이즈특성을 시간영역과 주파수 영역에서의 스펙트럼을 10 Hz에서 100hz까지 스캐닝하여 그 레벨을 측정하여 결과를 분석한 결과를 이용하여 6 dB이상의 시스템 마진을 더한 결과를 노이즈 소스로 공급하여 하드웨어의 오동작 및 하드웨어의 손상이 없음을 검증하였다. 본 시험은 아리랑 1호 위성의 공동개발을 수행한 미국 TRW 사의 위성체 조립시험장에서 수행되었다.

  • PDF

한시적 스트리트 퍼니처의 사례와 특성에 관한 연구 - 공사장 가설울타리와 가림막을 대상으로 - (Research on Characteristics and Actual Cases of Temporary Street Furniture -Focused on the Tentative Construction and Screen Fences at Construction Sites-)

  • 배현미
    • 한국가구학회지
    • /
    • 제20권1호
    • /
    • pp.21-30
    • /
    • 2009
  • This research is conducted on temporary street furniture, which is one of the significant factors that comprise the street landscape in modem cities. The primary purpose of this research is to present the guidance on direction of planning by examining the design and installation types of construction and screen fences usually established at construction sites for buildings, roads, parks and etc. The results are as follows: 1. The construction and screen fences at construction sites of urban areas used to be a mere tentative facility to prevent noise and safety accidents but have now incremented their roles to serve not only as a functional but also as an aesthetic element with a city view and harmonization with other elements taken into consideration. In particular, it is noticeable that, based on its unique feature of tentativeness, its role has developed to serve as street furniture that adds variability to the modem city. 2. There are two different types of screen fences: blackout type and transparent type. The transparent screen turns out to be used a lot at the construction site of building a skyscraper or differentiated building in downtown city area or in places where there are buildings of similar types and shapes located along the street in the vicinity of the construction site. 3. The actual cases of adopting the tentative construction and screen fences all at the same time as a single unit have been found in historically and culturally significant architectures with the screen design used to demonstrate the view after completion of construction or the characteristics of the architecture.

  • PDF

최적선형필터를 이용한 망막신경절세포 Spike Train으로부터의 시각자극 세기 변화 추정 (Estimation of Visual Stimulus Intensity From Retinal Ganglion Cell Spike Trains Using Optimal Linear Filter)

  • 류상백;김두희;예장희;김경환;구용숙
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.212-217
    • /
    • 2007
  • As a preliminary study for the development of electrical stimulation strategy of artificial retina, we set up a method fur the reconstruction of input intensity variation from retinal ganglion cell(RGC) responses. In order to estimate light intensity variation, we used an optimal linear filter trained from given stimulus intensity variation and multiple single unit spike trains from RGCs. By applying ON/OFF stimulation(ON duration: 2 sec, OFF duration: 5 sec) repetitively, we identified three functional types of ganglion cells according to when they respond to the ON/OFF stimulus actively: ON cell, OFF cell, and ON-OFF cell. Experiments were also performed using a Gaussian random stimulus and a binary random stimulus. The input intensity was updated once every 90 msec(i. e. 11 Hz) to present the stimulus. The result of reconstructing 11 Hz Gaussian and binary random stimulus was not satisfactory and showed low correlation between the original and reconstructed stimulus. In the case of ON/OFF stimulus in which temporal variation is slow, successful reconstruction was achieved and the correlation coefficient was as high as 0.8.

Simultaneous gap arthroplasty and intraoral distraction and secondary contouring surgery for unilateral temporomandibular joint ankylosis

  • Sharma, Aditi;Paeng, Jun-Young;Yamada, Tomohiro;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.12.1-12.6
    • /
    • 2016
  • Background: Temporomandibular joint (TMJ) ankylosis can be accompanied by various degrees of functional and esthetic problems. Adequate mouth opening, occlusal stability, and harmonious facial form are the main goals of treatment for ankylosis. Distraction osteogenesis has proven to be an excellent treatment for lengthening the ramus-condyle unit. However, various timings for distraction have been suggested, and there is no consensus on selection criteria for performing the procedure in stages or simultaneously with other treatments. Case presentation: In this case report, concomitant intraoral distraction and gap arthroplasty was planned to treat TMJ ankylosis and associated facial asymmetry. After gap arthroplasty and 23 mm of distraction, the ramus-condyle segment was successfully lengthened and mouth opening range was significantly increased. The resultant interocclusal space was stably maintained with an occlusal splint for 4 months after distraction. Finally, good occlusion was achieved after prosthetic treatment. The remaining mandibular asymmetry was corrected with osseous contouring and augmentation surgery. The mouth-opening range was maintained at 35 mm 24 months after treatment. Conclusion: Gap arthroplasty with intraoral distraction as a one-stage treatment and subsequent contouring surgery can be applied to correct ankylosis with moderate malocclusion and facial asymmetry.