• 제목/요약/키워드: Functional Fluids

검색결과 45건 처리시간 0.029초

Electrostatic Adsorption of Uniformly Charged Electrolytes within Like-charged Electrodes

  • Jang, Seanea;Shin, Ghi Ryang;Kim, Soon-Chul
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1315-1323
    • /
    • 2018
  • The classical-fluids density functional theory has been developed for studying the structural and the electrical properties of electrolyte solutions containing uniformly charged hard-spherical ions. The modified fundamental-measure theory has been used to evaluate the hard-sphere contribution. The mean-field approximation has been employed to calculate the cross correlation between the hard sphere contribution and the Coulomb interaction. The Poisson equation for ions carrying charges that are spatially separated has been solved. The present theory shows reasonably good agreement with the corresponding Monte Carlo simulation results. The calculated results show that the attraction between like-charged planar surfaces is the result of the intra-ionic correlation and depends strongly on the ion size, valence, mole fraction, and charge distribution of electrolytes.

부인과 암 이후 이차적인 다리 림프 부종 환자에게 적용한 림프흡수 마사지의 효과 (Effects of Manual Lymph Drainage on Patients with Secondary Lymphedema of Legs After Gynecologic Cancer)

  • 정성관;이승병
    • 대한정형도수물리치료학회지
    • /
    • 제22권2호
    • /
    • pp.35-39
    • /
    • 2016
  • Background: The superficial lymphatic system is divided into areas called lymphatic territories which are separated by watersheds. When the lymphatic system fails to remove its load either due to surgery, radiotherapy or some congenital malformation of it then the fluid and the proteins and wastes contained within it accumulates in that territory. Anastomotic connections exist across the watersheds and while they can work unaided manual lymph drainage (MLD) can significantly help drainage across them into unaffected lymphatic territories. The purpose of the study is to examine the effectiveness of a manual technique in moving fluids and softening hardened tissues using a tape measure and Patient-Specific Functional Scale. Methods: We examined the movement of fluids from the affected limbs of lymphedema patients who underwent a standardized 30-min treatment using the Dr. Vodder method of MLD. We chose a typical cross section of patients with secondary leg or secondary arm lymphedema. The lymphedema patient was also measured after the conclusion of treatment and underwent a follow-up control measurement, within 8 weeks. Both evaluation tools indicated a movement of fluid to different and unblocked lymphatic territories as well as a softening of tissues in some of the affected limbs. Results: MLD is an effective means of fluid clearance when it accumulates as a consequence of a failure of the lymphatic system. It seems likely that MLD has a systemic effect on the lymphatic system and that it can improve flow from otherwise normal tissues. Conclusions: It is hypothesized that a series of treatments would result in even more significant improvements.

  • PDF

ER 유체와 압전작동기를 이용한 엔진마운트의 모델링 및 제어 (Modeling and Control of an Engine Mount Using ER Fluids and Piezoactuators)

  • 최승훈;최영태;최승복
    • 대한기계학회논문집A
    • /
    • 제20권2호
    • /
    • pp.500-510
    • /
    • 1996
  • This paper presents a new prototype of an engine mount for a passenger vehicle featuring ER(elector-rheological) fluids and piezoactuators. Conventional rubber mounts and various types of passive or semi-active hydraulic engine mounts have their own functional aims on the limited frequency band in the board engine operating frequency range. However, the proposed engine mount covers all frequency range of the engine operation. A mathematical model of the proposed engine mount is derived using the bond graph method which is inherently domain, the ER fluid is activated upon imposing electric field for vibration isolation while the piezoactuator. Computer control electric fluid for the ER fluid H.inf. cotrol technique is adopted for the piezoactuator. Computer simulation is undertaken in order to demonstrate isolation efficiency of the engine mount over wide operating frequency range.

원심펌프 임펠러 입구각도 변화에 따른 유동해석 (FLOW ANALYSIS OF THE IMPELLER WITH DIFFERENT INLET ANGLES IN THE CENTRIFUGAL PUMP)

  • 이성현;이동렬
    • 한국전산유체공학회지
    • /
    • 제21권1호
    • /
    • pp.58-63
    • /
    • 2016
  • This research is to investigate the performance analysis for efficient design with four different inlet angles of the centrifugal pump impeller. Assuming that the rotation speed and exit angle are fixed, Four cases of the centrifugal pumps were numerically analyzed using ANSYS FLUENT. According to the numerical results, head and pump efficiency at inlet angle of 20 degrees was highest. There is no big difference of efficiency at inlet angle of 20 degrees compared to the inlet angle 30 degrees. About 15% of efficiency at inlet angle of 20 degrees is higher than inlet angle of 40 degrees and 31% higher than inlet angle oof 50 degrees. Because there is liner functional relationship between speed and flow rate, suction flow rate at inlet angle of 20 degrees is superior to the inlet angle of 30 degrees as much as 0.89%, inlet angle of 40 degrees as 13%, inlet angle of 50 as 28.4%. Head at inlet angle of 20 degrees is superior to the inlet angle of 30 degrees as much as 0.4%, inlet angle of 40 degrees as 2.7%, inlet angle of 50 degrees as 3.2%. There should exist highest efficiency and also optimal design shape at inlet angle of 20 degrees.

Study on the Inclusion Behavior of Sulfobutylether-β-Cyclodextrin with Perphenazine by Flow Injection Chemiluminescence

  • Shen, Minxia;Lv, Hairu;Song, Zhenghua
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3199-3205
    • /
    • 2013
  • The inclusion behavior of sulfobutylether-${\beta}$-cyclodextrin (SBE-${\beta}$-CD) with perphenazine (PPH) was first studied by flow injection (FI)-chemiluminescence (CL) analysis with proposed $lg[(I_0-I_s)/I_s]=lgK_{P-CD}+nlg[C_{PPH}]$ model and molecular docking. Results showed that a 1:1 complex of SBE-${\beta}$-CD/PPH could online form, with the formation constant $K_{P-CD}$ of $2.57{\times}10^7Lmol^{-1}$ at 298 K. The thermodynamic parameters showed that the inclusion behavior of SBE-${\beta}$-CD/PPH was a spontaneous process by hydrophobic interaction. The molecular docking results revealed PPH entered into the larger cavity of SBE-${\beta}$-CD with two hydrogen bonds. Based on the linear relationship of the decrement of luminol/SBE-${\beta}$-CD/PPH CL intensity against the logarithm of PPH concentration ranging from 0.03 to 30.0 ng $mL^{-1}$, the present FI-CL analysis using luminol/SBE-${\beta}$-CD/PPH system was successfully applied to PPH determination in biological fluids and tablets with recoveries from 94.5 to 105.6% and RSDs less than 2.6% (n = 5).

자기점성유체를 이용한 가변감쇠 마운트의 모델화 (A Modeling of a Variable-damping Mount Using Magneto-Rheological Fluid)

  • 안영공;양보석;삼하신
    • 소음진동
    • /
    • 제11권1호
    • /
    • pp.141-146
    • /
    • 2001
  • This paper deals with an application of Magneto-Rheological (MR) fluid to a small size mount for precision equipment of automobiles. MR fluid is known as a class of functional fluids with controllable apparent viscosity of fluid by the applied magnetic field strength. A typical MR fluid is a suspension where pure iron particles of 1-20 (m in diameter are dispersed in a liquid such as mineral oil or silicone oil, at the concentration of 20 - 40 vol%. Electro magnetic coil is installed at the bottom of a variable-damping mount filled with MR fluid, and performance of the mount was investigated experimentally. Furthermore, the Properties of the MR Mount on experimental study were explained analytically by mechanical model of the MR mount.

  • PDF

S-duct 내부유동의 출구경계조건 및 난류모텔의 영향검토 (Effects of Outflow Boundary Conditons and Turbulent Models on an S-duct Flow)

  • 홍승규;이광섭
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2000년도 춘계 학술대회논문집
    • /
    • pp.120-126
    • /
    • 2000
  • An S-duct flow is subjected to an entrance flow of Mach 0.6. The duct turns $30^{\circ}$ and reverses its turn by $30^{\circ}$ followed by a straight section. Such an internal flow induces a secondary flow due to curvature effect. Goal of this paper is to show the sensitivity of outflow boundary conditions on the quality of numerical solutions as well as to show curvature effect on the flow field. The often-used Baldwin-Lomax turbulence model is shown to be less functional on the concave region when the secondary flow has its strong Influence.

  • PDF

장력제어용 고출력 MR 브레이크 (A Study on High-output MR (Magneto-rheological) Brake for Tension Control)

  • 박중호;김진규;윤동원;함상용;노종호;유진산
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1422-1427
    • /
    • 2007
  • MR fluid is a suspension of micrometer-sized magnetizable particles in silicon oil and a functional fluid whose apparent viscosity can be controlled by the applied magnetic field strength. In this paper, a rotary brake using MR fluid called MR brake for tension control of precision machinery such as roll-to-roll printing machinery is presented. First, to obtain the higher performance than conventional powder brake, a MR brake with a modified rotor shape is newly designed and analyzed using FEM. Second, the prototype of MR brake is fabricated with the optimized structural parameters and an experimental apparatus is constructed. Then, basic characteristics of the MR brake are investigated with the different MR fluids. Finally, the validity of the developed MR brake is verified through the comparison with the conventional powder brake.

  • PDF

Fecal Retention in Overactive Bladder (OAB) in Children: Perspective of a Pediatric Gastroenterologist

  • Jeong, Su Jin
    • Childhood Kidney Diseases
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2015
  • Coexisting voiding and bowel dysfunction in children are common in the clinic. The idea that overactive bladder (OAB) and constipation arise from one single pathophysiology has been reinforced in many studies. In Korea, a nationwide multicenter study conducted in 2009 showed that overall prevalence of OAB in children, 5-13 years of age, was 16.59% and this number has increased more recently. The initial step to manage coexisting fecal retention and OAB in children is to characterize their bowel and bladder habits and to treat constipation if present. Although diagnosing constipation in children is difficult, careful history-taking using the Bristol Stool Form Scale, and a scoring system of plain abdominal radiography, can help to estimate fecal retention more easily and promptly. Non-pharmacological approaches to manage functional constipation include increasing fluids, fiber intake, and physical activity. Several osmotic laxatives are also effective in improving OAB symptoms and fecal retention. Additionally, correction and education in relation to toilet training is the most important measure in treating OAB with fecal retention.

MR 유체를 이용한 가변 감쇠 마운트의 모델화 (A Modeling of a Variable-damping Mount Using MR Fluid)

  • 안영공;;양보석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1338-1343
    • /
    • 2000
  • This paper deals with an application of Magneto-Rheological (MR) fluid to a small size mount for precision equipment of automobiles. MR fluid is known as a class of functional fluids with controllable apparent viscosity of fluid by the applied magnetic field strength. A typical MR fluid is a suspension where pure iron particles of $1{\sim}20mm$ in diameter are dispersed in a liquid such as mineral oil or silicone oil, at the concentration of $20{\sim}40$ vol%. Electro magnetic coil is installed at the bottom of a variable-damping mount filled with MR fluid, and its performance was investigated experimentally. Furthermore, the properties of the MR Mount on experimental Study were explained analytically by mechanical model of the MR mount.

  • PDF