• 제목/요약/키워드: Fume

검색결과 793건 처리시간 0.025초

Effect of different binders on cold-bonded artificial lightweight aggregate properties

  • Vali, Kolimi Shaiksha;Murugan, S. Bala
    • Advances in concrete construction
    • /
    • 제9권2호
    • /
    • pp.183-193
    • /
    • 2020
  • The present investigation is to identify an optimum mix combination amongst 28 different types of artificial lightweight aggregates by pelletization method with aggregate properties. Artificial aggregates with different combinations were manufactured from fly ash, cement, hydrated lime, ground granulated blast furnace slag (GGBFS), silica fume, metakaolin, sodium bentonite and calcium bentonite, at a standard 17 minutes pelletization time, with 28% of water content on a weight basis. Further, the artificial aggregates were air-dried for 24 hours, followed by hardening through the cold-bonding (water curing) process for 28 days and then testing with different physical and mechanical properties. The results found the lowest impact strength value of 16.5% with a cement-hydrated lime (FCH) mix combination. Moreover, the lowest water absorption of 16.5% and highest individual pellet crushing strength of 36.7 MPa for 12 mm aggregate with a hydrated lime-GGBFS (FHG) mix combination. The results, attained from different binder materials, could be helpful for manufacturing high strength artificial aggregates.

Fundamental Properties of Concrete Using the Ground Calcium Slurry Carbonate

  • Moon, Han-Young;Jung, Ho-Seop;Park, Doo-Sun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.560-564
    • /
    • 2001
  • Nowadays, according to the trend of a high performance of concrete structure, the research results have been announced for the purpose to make the high quality. With this respect, we began research to use the Ground Calcium slurry Carbonate (GCC) to a concrete admixtures which ground the limestone until about $1.5mutextrm{m}$. In this paper, we examined the quality of GCC to fine out the value in use as the concrete admixtures. And mechanical properties of concrete using cement blended with GCC, silica fume and mixed two were investigated. It was result from this study that air contents of concrete replaced with GCC were constant regardless of replacement ratio, but the more GCC it had the use of, the less slump was measured. Especially 10% GCC concrete had a good result of compressive strength. In case of mixture with GCC and silica fume, the workability and compressive strength don't seem to be any problems. In the scope of this study it was indicated that the most reasonable replacement with GCC was 10% of cement weight as concrete admixture.

  • PDF

포러스 콘크리트의 배합요인 및 골재 혼합비율이 강도 및 투수성능에 미치는 영향 (Influence of Mix Factors and Mixing Ratio of Aggregate on the Strength and Water Permeability of Porous Concrete)

  • 김무한;김규용;백용관
    • 콘크리트학회논문집
    • /
    • 제12권6호
    • /
    • pp.91-98
    • /
    • 2000
  • Porous concrete having continuous voids is gaining more interest as an ecological material. It has several useful functions such as water and air permeability, sound absorption, etc. Its strengths are considerably lower than those of conventional concrete due to the large and continuous voids in it. This study has been carried out to investigate the influence of mix factors and mixture proportion of aggregate on the strengths and water permeability of porous concrete. And it has been carried out to investigate the evaluation of void of porous concrete by the ultra-sonic pulse velocity. The results f this study are as follows: 1) The theoretical void ratio has greater influence than any other factor on the strengths and water permeability of porous concrete. And it is a little affected by the replacement proportion of silica-fume and mixture proportion of aggregate. 2) Because the coefficients of correlation between the void ratio and ultra-sonic pulse velocity were relatively high, it will be possible that the void ratio is predicted by the ultra-sonic pulse velocity.

고성능 감수제 종류에 따른 실리카흄이 혼입된 시멘트 수화 특성 (Influence of Superplastisize Types on Hydration of Cement with Silica Fume)

  • 강현주;송명신;박종헌;송수재
    • 한국세라믹학회지
    • /
    • 제48권6호
    • /
    • pp.504-509
    • /
    • 2011
  • In this study, the effect of superplasticizers on the dispersibility and hydration properties of cement with silica fume were investigated. Superplasticizers are used Naphthalene type, Ligno-sulfate type and polycarboxylate type. Compared with plastic viscosity of cement paste without superplasticizers(Plain), plastic viscosity of cement paste with superplasticizers are reduced and yield stress of cement pastes with each superplasticizer is increased rather than Plain. And then, plastic viscosity of cement paste with Naphthalene type superplasticizer was the least of all types. Compared with other two types, setting and hydration of cement paste with Polycarboxylate type(PC) superplasticizer is very fast. At compressive strength after 3-day, PC is higher than other two types, But, compressive strength of after 7-day and 28-day, PC is smaller than other two types.

Steel - concrete bond potentials in self-compacting concrete mixes incorporating dolomite powder

  • Kamal, Mounir M.;Safan, Mohamed A.;Al-Gazzar, Mohamed A.
    • Advances in concrete construction
    • /
    • 제1권4호
    • /
    • pp.273-288
    • /
    • 2013
  • The main objective of this research was to evaluate the potentials of self-compacting concrete (SCC) mixes to develop bond strength. The investigated mixes incorporated relatively high contents of dolomite powder replacing Portland cement. Either silica fume or fly ash was used along with the dolomite powder in some mixes. Seven mixes were proportioned and cast without vibration in long beams with 10 mm and 16 mm steel dowels fixed vertically along the flowing path. The beams were then broken into discrete test specimens. A push-put configuration was adopted for conducting the bond test. The variation of the ultimate bond strength along the flowing path for the different mixes was evaluated. The steel-concrete bond adequacy was evaluated based on normalized bond strength. The results showed that the bond strength was reduced due to Portland cement replacement with dolomite powder. The addition of either silica fume or fly ash positively hindered further degradation as the dolomite powder content increased. However, all SCC mixes containing up to 30% dolomite powder still yielded bond strengths that were adequate for design purpose. The test results demonstrated inconsistent normalized bond strength in the case of the larger diameter compared to the smaller one.

실리카흄을 혼합(混合)한 콘크리트의 고강도화(高强度化)에 관한 기초적(基礎的) 연구(研究) (A Fundamental Study on the High Strength Concrete Using Silica Fume)

  • 문한영;김진철
    • 대한토목학회논문집
    • /
    • 제12권4_1호
    • /
    • pp.33-41
    • /
    • 1992
  • 콘크리트의 강도를 크게 향상시키기 위한 연구의 일환으로 이산화규소의 함유량이 90% 이상이며, 평균입경이 $0.2{\mu}m$ 정도되는 비정질의 실리카흄을 결합재의 일부로 대체하고 고성능감수제를 사용하여 물-결합재비를 대폭 감소시킨 모르터와 콘크리트를 제조하여 재령 28일에 압축강도의 최대값이 각각 $865kg/cm^2$$725kg/cm^2$의 고강도모르터 및 콘크리트를 얻었다. 그러나 굳지 않은 콘크리트의 믹싱후 경과시간에 따른 슬럼프 손실이 큰 점과 아울러 인장강도 및 탄성계수가 크게 향상되지 않은 점이 충분히 해결되지 않았다.

  • PDF

혼화재를 사용한 고강도 경량콘크리트에 관한 실험적 연구 (An Experimental Study on High Strength Lightweight Concrete Using Compound Materials)

  • 김종인;최영화;김정훈
    • 한국산업융합학회 논문집
    • /
    • 제6권2호
    • /
    • pp.115-122
    • /
    • 2003
  • This experimental study on high strength lightweight concrete using compound materials has been performed. In which, expanded clay was used as coarse aggregate, and silica fume and fly ash as admixtures varying by 0, 10% and 0, 5, 10, 15, 20% of cement amount respectively were added. Thus, the properties of fresh and hardened concrete have been investigated. The results of this study can be summarized as follows ; Each slump loss of mixtures replaced fly ash has been decreased by increasing replacement rate. The compressive strength have shown 465, 428 and $401kgf/cm^2$ at 30, 40 and 50% of W/B in 28days respectively, all of which have satisfied the criterion $270kgf/cm^2$ of high strength lightweight concrete. The unit volume weight of hardened concrete has been decreased by increasing replacement rate of silica fume and fly ash, values of which have satisfied the criterion $2000kgf/cm^3$of light weight concrete.

  • PDF

혼화재료가 보수용 폴리머 시멘트 모르타르의 성질에 미치는 영향 (Effects of Admixtures in Properties of Polymer Cement Mortar for Concrete Repair)

  • 송형수;이진용;민창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.85-94
    • /
    • 2007
  • 재유화형 폴리머는 보수용 모르타르의 개질재료로 주로 사용되고 있으며, 이러한 보수용 폴리머 시멘트 모르타르에는 폴리머 이외에 각종 혼화재료가 첨가된다. 기존의 연구들은 시멘트-폴리머 비가 모르타르에 미치는 영향에 대하여 주로 이루어졌으며, 혼화재료가 폴리머 시멘트 모르타르에 미치는 영향은 보고 되어있지 않는 실정이다. 본 연구에서는 혼화재료들(CSA계 팽창재, CSA계 속경재, 석고, 실리카 흄)의 배합비율에 따라 폴리머 시멘트 모르타르에 미치는 영향을 분석하고자 모르타르의 작업성, 응결시간, 건조수축, 압축강도, 휨 및 부착강도 등의 기초적 성질에 대하여 실험적으로 구명하였다.

고반응성 메타카올린을 사용한 고성능 콘크리트의 특성 (Properties of High-Performance Concrete Containing High - Reactivity Metakaolin)

  • 원종필;권연성;이존자
    • 콘크리트학회논문집
    • /
    • 제14권3호
    • /
    • pp.349-356
    • /
    • 2002
  • 본 연구는 고반응성 메타카올린(HRM)을 혼입한 고성능 콘크리트(HPC)의 굳지 않은 콘크리트와 경화된 콘크리트의 특성을 평가하기 위해 수행되었다. 굳지 않은 콘크리트에 대해서는 공기량과 슬럼프 플로우, 응결시간 및 수화열 측정 시험을 실시하였다. 경화된 콘크리트에 대해서는 압축강도 및 염화물 투수시험, 마모저항성, 동결ㆍ응해 저항성 시험을 하였다. HRM 콘크리트의 특성은 또한 보통 포틀랜드 시멘트 콘크리트와 실리카 흄 콘크리트와 비교하여 나타내었다. 실험 결과 HRM 재료가 고성능 콘크리트를 생산하기 위한 시멘트 대체 재료로서 사용할 수 있음을 보여주었다.

Behavior of high-strength fiber reinforced concrete plates under in-plane and transverse loads

  • Ramadoss, P.;Nagamani, K.
    • Structural Engineering and Mechanics
    • /
    • 제31권4호
    • /
    • pp.371-382
    • /
    • 2009
  • The concrete plates are most widely used structural elements in the hulls of floating concrete structures such as concrete barges and pontoons, bridge decks, basement floors and liquid storage tanks. The study on the behavior of high-strength fiber reinforced concrete (HSFRC) plates was carried out to evaluate the performance of plates under in-plane and transverse loads. The plates were tested in simply supported along all the four edges and subjected to in-plane and traverse loads. In this experimental program, twenty four 150 mm diameter cylinders and twelve plate elements of size $600{\times}600{\times}30$ mm were prepared and tested. Water-to-cementitious materials ratios of 0.3 and 0.4 with 10% and 15% silica fume replacements were used in the concrete mixes. The fiber volume fractions, $V_f$ = 0%, 1% and 1.5% with an aspect ratio of 80 were used in this study. The HSFRC mixes had the concrete compressive strengths in the range of 52.5 to 70 MPa, flexural strengths ranging from 6.21 to 11.08 MPa and static modulus of elasticity ranging from 29.68 to 36.79 GPa. In this study, the behavior of HSFRC plate elements subjected to combined uniaxial in-plane and transverse loads was investigated.