• Title/Summary/Keyword: Fully-Developed Condition

Search Result 184, Processing Time 0.026 seconds

Development of the Large-Capacity Mooring Fittings according to MEG4(Mooring Equipment Guideline 4) (MEG4(Mooring Equipment Guideline 4) 적용에 따른 대용량 무어링 피팅 개발)

  • Myung-Su Yi;Kwang-Cheol Seo;Joo-Shin Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.950-957
    • /
    • 2023
  • For safe mooring and towing between the ship and port, the equipment must be designed in accordance with the relevant international regulations. However, some small shipyards and engineering companies often do not fully comprehend the core contents. Therefore, the international regulations regarding towing and mooring equipment are reviewed and the bollard and chock are newly developed based on the Mooring Equipment Guideline 4 (MEG4) standards. A bollard is a mooring equipment used to fix a mooring rope to the hull. It has two columns and is mostly used in a figure eight pattern knots under the mooring condition. The chock, which is used to change the mooring rope direction coming into the ship from outside, is manufactured using a casting with curvature. The two mooring equipment are widely used in the stern, bow, and mid-side. Owing to the increase in the size of container vessels and LNG ships, the mooring rope load has increased and the safe working load of the mooring equipment must be revised. This study summarizes and examines the results of the allowable stress method obtained using finite element analysis modelling. To consider the mesh size effect, a reasonable criteria was suggested by referring the existing class guidance. Additionally, the safe working load was verified through nonlinear collapse analysis, and the elastic region against load increments was confirmed. Furthermore, the proposed evaluation method can be used to develop similar equipment in the near future.

Effects of Maturation Duration and Activation Treatments on Activation and Development of Porcine Follicular Oocytes (돼지 난모세포의 단위발생에 있어서 성숙시간과 활성화 처리가 활성화와 발달에 미치는 영향)

  • Kim H. J.;Choi S. H.;Han M. H.;Son D. S.;Ryu I. S.;Kim I. C.;Lee J. H.;Kim I. H.;Im K. S.;Cho S. R.
    • Journal of Embryo Transfer
    • /
    • v.20 no.1
    • /
    • pp.25-33
    • /
    • 2005
  • This study is a part of research that development of effective genetic resources preservation system using the in vitro spermatogenesis, in vitro insemination and culture system. We aimed for establishment of in vitro culture system with in vitro activated porcine oocytes. The porcine oocytes were matured for 48 hours in $TCM199+10\%$ FCS and activated with $7\%$ ethanol. The activated oocytes were cultured for 7 days in $TCM199+10\%$ FCS or $NCSU23+0.4\%$ BSA medium. The activated oocytes were not developed to the blastocyst stage in $TCM199+10\%$ FCS medium. However in $NCSU23+0.4\%$ medium, those were developed to blastocyst with $3\%$ of treated oocytes. We extended maturation duration of porcine follicular oocytes fur 48, 52, 56, 60, 64, 68, and 72 hours and activated with $7\%$ ethanol and cultured using $NCSU23+0.4\%$ BSA medium. The six percents of activated oocytes were developed to blastocyst in 48 hours and $10\%$ in 52 hours with comparatively low rates suggested to be not fully activated by regenerated MPF. Maturation durations from 56 hours to 68 hours supported to develop upto $11.9\~18.3\%$ of blastocysts. However the developmental rate was declined to $7.2\%$ at 72 hours of maturation duration because of cytoplasmic deterioration. The assumed time window for activation will be $56\~68$ hours of maturation duration. When the matured oocytes were activated with electric pulse of 1, 1.2, 1.4, 1.6, 1.8 and 2.0kV/cm for $80{\mu}s$, although appling the electric current once was not enough for activation, appling twice with 1.6kV/cm for $80{\mu}s$ was shown the highest developmental rate with $11.3\%$. When those were compared with activating methods, $15.7%$ of blastocyst rate was obtained in the $7\%$ ethanol. That was higher than those in electric pulse with $9.5\%$ and calcium ionophore method with $5.8\%$. In this experimental condition, the $7\%$ ethanol treatment was the most effective method for activating porcine oocytes.

Variation of Inflow Density Currents with Different Flood Magnitude in Daecheong Reservoir (홍수 규모별 대청호에 유입하는 하천 밀도류의 특성 변화)

  • Yoon, Sung-Wan;Chung, Se-Woong;Choi, Jung-Kyu
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.12
    • /
    • pp.1219-1230
    • /
    • 2008
  • Stream inflows induced by flood runoffs have a higher density than the ambient reservoir water because of a lower water temperature and elevated suspended sediment(SS) concentration. As the propagation of density currents that formed by density difference between inflow and ambient water affects reservoir water quality and ecosystem, an understanding of reservoir density current is essential for an optimization of filed monitoring, analysis and forecast of SS and nutrient transport, and their proper management and control. This study was aimed to quantify the characteristics of inflow density current including plunge depth($d_p$) and distance($X_p$), separation depth($d_s$), interflow thickness($h_i$), arrival time to dam($t_a$), reduction ratio(${\beta}$) of SS contained stream inflow for different flood magnitude in Daecheong Reservoir with a validated two-dimensional(2D) numerical model. 10 different flood scenarios corresponding to inflow densimetric Froude number($Fr_i$) range from 0.920 to 9.205 were set up based on the hydrograph obtained from June 13 to July 3, 2004. A fully developed stratification condition was assumed as an initial water temperature profile. Higher $Fr_i$(inertia-to-buoyancy ratio) resulted in a greater $d_p,\;X_p,\;d_s,\;h_i$, and faster propagation of interflow, while the effect of reservoir geometry on these characteristics was significant. The Hebbert equation that estimates $d_p$ assuming steady-state flow condition with triangular cross section substantially over-estimated the $d_p$ because it does not consider the spatial variation of reservoir geometry and water surface changes during flood events. The ${\beta}$ values between inflow and dam sites were decreased as $Fr_i$ increased, but reversed after $Fr_i$>9.0 because of turbulent mixing effect. The results provides a practical and effective prediction measures for reservoir operators to first capture the behavior of turbidity inflow.

Seasonal Fluctuation, Reproduction, Development and Damaging Behavior of Compsidia populnea L.(Coleoptera; Cerambicidae) on Populus $alba{\times}glandulosa$ (현사시나무의 줄기 식입해충(害蟲) 포푸라하늘소의 생활사(生活史)에 관한 조사(調査))

  • Park, Kyu-Tek;Paik, Hung-Ryul
    • Korean journal of applied entomology
    • /
    • v.24 no.4 s.65
    • /
    • pp.195-201
    • /
    • 1986
  • This study was conducted to investigate the life history of Compsidia populnea which is major species of the stem-borers on Populus alba{\times}glandulosa$. Peak emergence of the adult of Compsidia populnea L. was around 10th${\sim}$l2nd of May in Chuncheon vicinities, having one generation a year in Korea. There was a preovipositional period of 10.7 days and a ovipositional period of 14.3.days. Mean adult longevity was 11 days for male and 13.8 days for female. Individual eggs were long oval with somewhat narrowed tip at one side and soft, 2.6mm in length, 0.8mm in diameter, and were laid singly under the U-shaped scars which were made by female before oviposition. Total number of scars per female averaged 56.6 ($8{\sim}135$) and eggs were found in 67.9 percent of the total scars. Egg period was $8{\sim}11$ days at $25^{\circ}C$ constant temperature and $7{\sim}14$ days in the field condition. Early young larvae stayed for $2{\sim}3$ weeks under the scars and then boring into the xylem, forming galls at this time. Size of the gall was 1.8cm($1.3{\sim}2.5$) in length, 1.6cm($1.0{\sim}2.2$) in diameter and the length of mine was everage 3.1cm. Fully grown larvae were developed around the early October and overwintered in the mines of galls. Pupation was done around the early of April. Pupal developmental period averaged 11 days($9{\sim}13$ days) at $25^{\circ}C$ constant temperature condition.

  • PDF

DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination (HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가)

  • Kwon, Ik-Soo;Hwang, Jae-Sang;Koo, Jae-Hong;Sakamoto, Kuniaki;Lee, Bang-Wook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.

The Modern Understanding and Misunderstanding about the Thirteen-story Stone Pagoda of Wongaksa Temple (원각사(圓覺寺)13층탑(層塔)에 대한 근대적 인식과 오해)

  • Nam, Dongsin
    • MISULJARYO - National Museum of Korea Art Journal
    • /
    • v.100
    • /
    • pp.50-80
    • /
    • 2021
  • This paper critically examines the history of the theories connected to the Wongaksa Temple Pagoda that have developed over the last 100 years focusing on the original number of stories the pagoda would have reached. Part II of this paper retraces the dynamic process of the rediscovery of the Wongaksa Temple Pagoda by Westerners who traveled to Korea during the port-opening period. Koreans at the time viewed the Wongaksa Temple Pagoda as an object of no particular appeal or even as an eyesore. However, Westerners appreciated it as a wonder or magnificent sight. Since these Westerners had almost no prior knowledge of Buddhist pagodas, they were able to write objective travelogues. At the time, these visitors generally accepted the theory common among Joseon intellectuals that Wongaksa Temple Pagoda once had thirteen stories. Part III focuses on Japanese government-affiliated scholars' academic research on the Wongaksa Temple Pagoda after the proclamation of the Korean Empire and the Japanese Government-General of Korea's subsequent management of the pagoda as a cultural property during the colonial era. It also discusses issues with Japanese academic research and management. In particular, this portion sheds light on the shift in theories about the original number of stories of the Wongaksa Temple Pagoda from the ten-story theory supported by Sekino Tadashi (關野 貞), whose ideas have held a great influence on this issue over the last 100 years, to the thirteen-story theory and then to the idea that it had more than thirteen. Finally, Part IV addresses the change from the multi-story theory to the ten-story theory in the years after Korea's liberation from Japan until 1962. Moreover, it highlights how Korean intellectuals of the Japanese colonial era predominantly accepted the thirteen-story theory. Since 1962, a considerable quantity of significant research on the Wongaksa Temple Pagoda has been published. However, since most of these studies have applied the ten-story theory suggested in 1962, they are not individually discussed in this paper. This retracing of the history of theories about the Wongaksa Temple Pagoda has verified that although there are reasonable grounds for supporting the thirteen-story theory, it has not been proved in the last 100 years. Moreover, the number of pagoda stories has not been fully discussed in academia. The common theory that both Wongaksa Temple Pagoda and Gyeongcheonsa Temple Pagoda were ten-story pagodas was first formulated by Sekino Tadashi 100 years ago. Since the abrasion of the Wongaksa Temple Stele was so severe the inscriptions on the stele were almost illegible, Sekino argued that the Wongaksa Temple Pagoda was a ten-story pagoda based on an architectural analysis of the then-current condition of the pagoda. Immediately after Sekino presented his argument, a woodblock-printed version of the inscriptions on the Wongaksa Temple Stele was found. This version included a phrase that a thirteen-story pagoda had been erected. In a similar vein, the Dongguk yeoji seungnam (Geographic Encyclopedia of Korea) published by the orders of King Seongjong in the late fifteenth century documented that Gyeongcheonsa Temple Pagoda, the model for the Wongaksa Temple Pagoda, was also a thirteen-story pagoda. The Wongaksa Temple Stele erected on the orders of King Sejo after the establishment of the Wongaksa Temple Pagoda evidently shows that Sekino's ten-story premise is flawed. Sekino himself wrote that "as [the pagoda] consists of a three-story stereobate and a ten-story body, people call it a thirteen-story pagoda," although he viewed the number of stories of the pagoda body as that of the entire pagoda. The inscriptions on the Wongaksa Temple Stele also clearly indicate that the king ordered the construction of the Wongaksa Temple Pagoda as a thirteen-story pagoda. Although unprecedented, this thirteen-story pagoda comprised a ten-story pagoda body over a three-story stereobate. Why would King Sejo have built a thirteen-story pagoda in an unusual form consisting of a ten-story body on top of a three-story stereobate? In order to fully understand King Sejo's intention in building a thirteen-story pagoda, analyzing the Wongaksa Temple Pagoda is necessary. This begins with the restoration of its original name. I disprove Sekino's ten-story theory built upon flawed premises and an eclectic over-thirteen-story theory and urge applying the thirteen-story theory, as the inscriptions on the Wongaksa Temple Stele stated that the pagoda was originally built as a thirteen-story pagoda.

The Predcitors of the Development of Acute Respiratory Distress Syndrome in the Patients with Acute Pancreatitis (급성 췌장염으로 내과계 중환자실에 입원한 환자들의 급성호흡곤란 증후군 발생에 연관된 인자에 관한 연구)

  • Yoo, Mi-Ran;Koh, Youn-Suck;Lim, Chae-Man;Lee, Moon-Gyu;Lee, Hong-Jae;Lee, Moo-Song;An, Jong-Jun;Lee, Sung-Koo;Kim, Myung-Hwan;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.861-870
    • /
    • 1997
  • Background : Though acute respiratory distress(ARDS) often occurs in the early stage of severe acute pancreatitis and significantly contributed to the mortality of the condition, the characteristics of the group who develops ARDS in the patients with acute pancreatitis have not been fully found. The objective of this investigation was to identify predictable factors which distinguish a group who would develop ARDS in the patients with acute pancreatitis. Method : A retrospective analysis of 94 cases in 86 patients who were admitted the Medical Intensive Care Unit with acute pancreatitis was done. ARDS were developed in 13 cases among them (13.8%). The possible clinical factors related to the development were analyzed using univariate analysis and $x^2$-test. Results : The risk of ARDS development was increased in the patients with abonormal findings of chest X-ray at admission compared to the patients with normal chest X-ray (p<0.05). The risk was also increased according to the sevecrity index score in abdominal computed tomography at the time of admission (p<0.05). The higher APACHE III score of the first day of admission, the more risk increment of ARDS development was observed (p<0.01). Patients with more than one points of Murray's lung injury score showed higher risk of ARDS compared to the patients with 0 points of that. The patients with sepsis and the patients with more than three organ dysfunction at admission had 3.5 times and 23.3 times higher risk of the development of ARDS compared to the patients without sepsis and without organ failure in each (p<0.05, p<0.01). Conclusion : The risk of ARDS development would be higher in the acute pancreatitis patients with abnormal chest X-ray, higher CT severity index, higher APACHE III or Murray's lung injury score, accompanying sepsis, and more than three organ failure at admission.

  • PDF

A study on the smile of Korean Youth compared with twenty years ago (20년전과 비교한 한국청년의 미소 변화에 관한 연구)

  • Beom, Seung-Gyun;Jung, Ji-Hye;Kim, Tae-Young;Lee, Kyung-Eun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Purpose: Teeth are generally exposed when people smiling. Moreover, the exposed teeth and soft tissue when smiling becomes an important guideline for esthetically prosthetic restoration. This research is to compare and find out differences of Korean young men's smile living in presence and twenty years ago. Materials and methods: Subjects, 100 young men (50 male and 50 female), were required about several aspects; normally developed physical condition, no psychological or genetic disorders, a fine face with no loss of teeth, no experience in orthodontic or prosthetic treatment, relatively normal occlusion, aged between 20-29. The photos of the subject at rest position and front face when fully smiled were taken three times. 100 photos (50 male and 50 female) were chosen at random from the 240 university students' smile photos taken by Yoon and his colleagues in 1991. By Hulsey's method of measuring smile, several factors; the change of upper lip curvature, the change of the relation between the upper lip and teeth, parallelism between Mx. incisor and lower lip, contact relation between Mx. incisor and lower lip and teeth displayed in a smile, were measured and analyzed. Meanwhile, ten dentists assessed aesthetic evaluation about men and women's smile for twice and recorded and compared smile score. The -test (P<.05) was used to compare the measured value. The difference of smile score was analyzed by t-test (P<.05). Results: The smile score calculated in 2011 (60.22) was higher than that of 1991 (52.80). Among five measurement categories, the noticeable difference was distinguished from two factors; the change of upper lip curvature and contact relation between Mx. incisor and lower lip. Conclusion: The Korean young men's smile has been considerably improved for twenty years. And it is found that the change of upper lip curvature plays an important role, that is, the smile formed with an ascended labial commissure has been increased significantly.

Problems of the Current Referral System of the Terminal Cancer Patients in Korea (말기 암 환자의 완화 의료 연계 시스템의 문제점과 개선 방안)

  • Yun, Cho-Hee;Lee, Ju-Young;Kim, Mi-Ra;Heo, Dae-Seok
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.2
    • /
    • pp.94-100
    • /
    • 2002
  • Purpose : The system to refer terminally ill patients to palliative or hospice care which ultimately give them emotional, psychological, and social support hasn't been fully developed and organized yet in Korea. The controversies concerning the current referral system are being analyzed to present the improvements. Methods : The questionnaires were asked to be filled out by family members of the 76 patients by phone interview, who were referred from the Seoul National University Hospital between April, 2001 to March, 2002. They were referred to the 35 palliative and hospice care-giving institutes and hospitals which were given questionnaires by mail. Results : Of the 76 patient's family members, 47 family members accepted to answer the questionnaire. The first thing that influence to family to determine the referral of patient was solicitation of doctors or nurses (44%). And they were influenced by allowance for the other things such as convenience of patients (32%), convenience of caring family members (24%). In the course of determining of referred institutes, responders had considered at first their dwelling area, and then fame of institutes, the place which patent had wanted to spend last hours or which is suitable for patient's funeral service, and their financial condition. Thirty-eight the 47 responders answered that they had experienced difficulties in referral procedure. The worst among difficulties was unwanted discharge, and followings were lack of information about the referred institutes, concern about patient's suffering, resistance of patient and opposition of other family members, etc. Although they expressed dissatisfaction in referral procedure, most of them answered they had been satisfied with hospice care at referred institute after referral. Merits of referral which responders counted were patient's peace, caring family's comfort and reduced cost in order. Of the 35 referred institutes, 24 institutes' staffs responded mail questionnaires and sent to us in return. Except one responder, the rest approved the referral system and thought that referred patients had been satisfied with their hospice care. And they claimed that systemic support of the government is definitely necessary. The most difficult thing which responders experienced in care of referred patients was lack of information about patients. Besides, there were patient's financial problems, lack of understanding about their institutes of patients or family, and inconvenience of terminal cancer patient's pain control. Conclusion : The development and support of the organized referral system is needed to alleviate the troubles which patients, family members, and palliative or hospice institutes and hospitals have to face through the procedure of the referral.

  • PDF

Management and Supporting System on the Occupational Health Nursing Services Provided in Group Occupational Health Agencies of Korea (소규모 사업장 보건관리대행기관의 간호업무 운영관리 지원체계)

  • Yoo, Kyung-Hae
    • Korean Journal of Occupational Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.193-211
    • /
    • 1999
  • This study was carried out to investigate the management and support system affecting to the occupational health nursing services(OHNS) provided in group occupational health agencies(GOHA). Questionnaire was developed and distributed to 82 nurses who were working in GOHA and who agreed to participate in the survey. The results were as follow: 1. OH nurses responded were mostly in the age of twenty to thirties(89%), married(73.7%), technical college graduates(88.9%), worked in hospital(85.4%) and participated more than 1 year in group occupational health services (96.3%). 2. Fifty eight point four percent of the OH nurses worked in number of workplace more than 30 to less than 60 in the OHNS form. The figure of workplaces undertaken by nurses was ranged greatly from 9 to more than 100. Number of employees who cared by nurses were mostly under 5,000 peoples in 93.3%. The types of industry was mostly manufacturing and located in the order of factory complex area, suburban, urban and others. 3. Most OH nurses(87.8%) were fully involved in the OHNS for the SSE. Their working days to visit SSE was 5 days per week(77.8%) and one day in the GOHA at 41.3%. 4. The OH documents using by nurses were found in more than 23 different types. However, they were largely summarized in the types of 'Workplace Health Management Card', 'Personal Health Counselling Card', 'Daily Health Management Report', 'Visiting List of Workplace' and 'Sick Employee List'. 5. The items of laboratory test provided by GOHA were mostly achieved in the purpose of basic health examination. They were used to be the blood pressure check(98.8%), blood sugar test (98.8%), urine sugar and protein(91.4%), SGOT and SGPT(85.3% each), cholesterol (82.9%), hepa vaccine immunization(82.9%), r-GPT(81.7%), hemoglobin(79.3%) and triglyceride(75.5%). 6. The OH nurses(92.7%) followed the work pattern to visit the GOHA before and after small-scale enterprises(SSE) visit by car driven by nurses in 74.3%. They were payed by GOHA for transportation fees in certain amounts. However, nurse is the main person(75.0%) who covers up in case of traffic accident. If the GOHA has no transportation regulation for the formal workplace visit, data showed that nurses had been responsible to take charge(31.7%). 7. The personnel manager who takes in charge for nursing services was 'nurse' in 61.7% and 41.2% worked as the final decision maker related to nursing work. The OH nurses' opinions about factors affecting to the management were classified in the four areas such as 'Nature(Quality) of health professional'. 'Content of OHNS', 'Delivery system of the GOHS', and 'Others'. The factors were indicated highly in 'Authority as health professional', 'Level of perception of director on the OH' and 'Physical work condition for OHNS'. The things that this study suggests in the recommendation would be summarized in such as the management and supporting system working for SSE in the OHNS is necessary to reform thoroughly. The reconsidered aspects might be in the matters of number of workplaces undertaken by nurses, development of effectively practical health documents, preparation for guideline of the laboratory test in the workpleces, establishment of convenient and encouraging support system and cooperation between other health professionals with respect and skill.

  • PDF