• Title/Summary/Keyword: Full-scan

Search Result 193, Processing Time 0.025 seconds

Development of a Custom-Made Dress Form for Draping Based on 3D Handheld Scanners and 3D Printing Technology (3D 핸디형 스캐너와 3D 프린팅 기술 기반 드레이핑용 커스텀 메이드 드레스폼 개발)

  • Ryu, Eun Joo;Song, Hwa Kyung
    • Fashion & Textile Research Journal
    • /
    • v.24 no.4
    • /
    • pp.451-459
    • /
    • 2022
  • This study aimed to develop a a custom-made dress form for draping using a live model's 3D body scan obtained from an entry-level 3D handheld scanners, 3D modeling software and 3D printing technology. A female subject was recruited whose body size fell under the normal (N) body shape criteria suggested by KS K 0051. First, the handheld scanner reduced the length of the legs in scanning, but most of the scanning operations between the neck and crotch levels were conducted accurately. Therefore, this study was designed to develop a torso dress form. The full body 3D scan was edited into a torso shape using ZBrush® software. Using Rhinoceros® and Materialise's Magics software, a 3D body scan was modeled so that the user could fit two types of mannequin stands (one with a neck fixation from above and one with an insert from below) to the dress form. The body scan was divided into 9 pieces to fit the printable size of the Stratasys 3D printer Fortus 250mc, and the cross-sectional distance from the center to the periphery was downsized by 2 mm. After outputting the dress form scan file with a 3D printer, the dress form was manufactured by the first covering it with a 4 oz nonwoven pad and the second covering with a single jersey material.

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

한반도 지형에 적합한 SAR 위성의 운영모드 설계

  • Shin, Jae-Min;Im, Jeong-Heum;Kim, Eung-Hyun;Lee, Sang-Kon;Lee, Sang-Ryool
    • Aerospace Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.34-41
    • /
    • 2004
  • In this paper, the SAR operational mode for achieving mission is designed. Each mode, which is the strip mode, scan mode, and fine mode, is basically considered. Based on the characteristics, which includes incidence angle, of the topography in Korean Peninsula, look angle for SAR satellite is determined. The limited region of operating the mission, which is considered to be able to receive and transmit the radar data, was defined to use determined operational mode. In the future, as considering full requirements and conditions for the SAR satellite, requirements and parameters will be discussed and studied.

  • PDF

Calibration Method of the Tomographic Gamma Scan Techniques Available for Accurately Characterizing 137Cs from 110mAg Interference (110mAg 간섭으로부터 137Cs 정량평가를 위한 드럼핵종분석 교정기술)

  • Jeong, Sung Yeop
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.57-61
    • /
    • 2016
  • The Tomographic Gamma Scan (TGS) technique partitions radioactive waste drums into $10{\times}10{\times}16$ voxels and assays both the density and concentration of radioactivity for each voxel thus providing for improved accuracy, when compared to the traditional Non-Destructive Assay(NDA) techniques. It could decrease the degree of precision measurement since there is a trade-off between spatial resolution and precision. This latter drawback is compensated by expanding the Region of Interest (ROI) that differentiates the full energy peaks, which, in turn, results in an optimized degree of precision. The enlarged ROI, however, increases the probability of interference among those nuclides that emit energies in the adjacent spectrum. This study has identified the cause of such interference for the reference nuclide of the TGS technique, $^{137}Cs$ (661.66 keV, half-life 30.5 years), to be $^{110m}Ag$ (657.75 keV, half-life 249.76 days). A new calibration method of determining the optimized ROI was developed, and its effectiveness in accurately characterizing $^{137}Cs$ and eliminating the interference was further ascertained.

Verification of the Accuracy of Photogrammetry in 3D Full-Body Scanning -A Case Study for Apparel Applications-

  • Eun Joo Ryu;Lu Zhang;Hwa Kyung Song
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.1
    • /
    • pp.137-151
    • /
    • 2023
  • Stationary 3D whole-body scanners generally require 5 to 20 seconds of scanning time and cannot effectively detect armpit and crotch areas. Therefore, this study aimed to analyze the accuracy of a photogrammetric technique using a multi-camera system. First, dimensional accuracy was analyzed using a mannequin scan, comparing the differences between the scan-derived measurements and the direct measurements, with an allowable tolerance of ISO 20685-1:2018. Only 2 of 59 measurement items (ankle height and upper arm circumference, specifically) exceeded the ISO 20685-1:2018 criteria. When compared with the results of the eight stationary whole-body scanners assessed by the literature, the photogrammetric technique was found to have the advantage of scanning the top of the head, armpit, and crotch areas clearly. Second, this study found the photogrammetric technique is suitable for obtaining the body scans because it can minimize the perform scanning, resulting in a reduction of measurement errors due to breathing and uncontrolled movements. The error rate of the photogrammetry method was much lower than that of stationary 3D whole-body scanners.

3D Animation Body Profiles from Full-body Scans and Motion Capture (풀바디 스캔과 모션 캡처를 활용한 3D 애니메이션 바디 프로필)

  • Jaewon Song;Sang Wook Chun;Subin Lee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.3
    • /
    • pp.59-67
    • /
    • 2023
  • This paper proposes a 3D animated body profile using 3D body scanning and motion capture devices. Users can create their own personalized body profiles with animation by performing 3D scans for a predetermined set of poses. To achieve this, a template animation was obtained through motion capture for a series of poses, and the acquired 3D scan data from users was mapped to the key poses of the animation using Pose-space deformer. The resulting 3D animated body profiles provide users with greater satisfaction compared to traditional static 2D images or 3D scan data.

Deblurring of the Blurred Image Caused by the Vibration of the Interlaced Scan Type Digital Camera (인터레이스드 스캔방식 디지털 카메라의 떨림에 의한 영상블러 제거)

  • Chon Jcechoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.2
    • /
    • pp.165-175
    • /
    • 2005
  • If the interlaced scan type camera moves while an image is filming from the camera, blur is often created from the misalignment of the two images of even and odd lines. This paper proposed an algorithm which removes the misalignment of the even and odd line images cased by the vibration of the interlaced scan type camera. The blurred original image is separated into the even and the odd line images as half size. Based on these two images, two full sized images are generated using interpolation technique. If a big difference between these two interpolated images is generated, the original image is taken while the camera is moving. In this case, a deblurred image is obtained with the alignment of these separated two images through feature point extraction, feature point matching, sub-pixel matching, outlier detection, and image mosaicking processes. This paper demonstrated that the proposed algorithm can create clear images from blurred images caused by various camera motions.

Design-for-Testability of The Floating-Point DSP Processor (부동 소수점 DSP 프로세서의 테스트 용이 설계)

  • Yun, Dae-Han;Song, Oh-Young;Chang, Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.5B
    • /
    • pp.685-691
    • /
    • 2001
  • 본 논문은 4단계 파이프 라인과 VLIW (Very Long Instruction Word) 구조를 갖는 FLOVA라는 DSP 프로세서의 테스트용이 설계 기법을 다룬다. Full-scan design, BIST(Built-In-Self-Test), IEEE 1149.1의 기법들이 플립플롭과 floaing point unit, 내장된 메모리, I/O cell 등에 각각 적용되었다. 이러한 기법들은 테스트 용이도의 관점에서 FLOVA의 구조에 적절하게 적용되었다. 본 논문에서는 이와 같이 FLOVA에 적용된 테스트 용이 설계의 특징들을 중심으로 상세하게 기술한다.

  • PDF

A Study on the Inner Defect Inspection for Semiconductor Package by ESPI (ESPI를 이용한 반도체 패키지 내부결함 검사에 관한 연구)

  • Jung, Seung-Tack;Kim, Koung-Suk;Yang, Seung-Pil;Jung, Hyun-Chul;Lee, You-Hwang
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1442-1447
    • /
    • 2003
  • Computer is a very powerful machine which is widely using for data processing, DB construction, peripheral device control, image processing etc. Consequently, many researches and developments have progressed for high performance processing unit, and other devices. Especially, the core units such as semiconductor parts are rapidly growing so that high-integration, high-performance, microminiat turization is possible. The packaging in the semiconductor industry is very important technique to de determine the performance of the system that the semiconductor is used. In this paper, the inspection of the inner defects such as delamination, void, crack, etc. in the semiconductor packages is studied. ESPI which is a non-contact, non-destructive, and full-field inspection method is used for the inner defect inspection and its results are compared with that of C-Scan method.

  • PDF