• Title/Summary/Keyword: Full-scale converter

Search Result 22, Processing Time 0.025 seconds

A Rail-to-Rail Input 12b 2 MS/s 0.18 μm CMOS Cyclic ADC for Touch Screen Applications

  • Choi, Hee-Cheol;Ahn, Gil-Cho;Choi, Joong-Ho;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.3
    • /
    • pp.160-165
    • /
    • 2009
  • A 12b 2 MS/s cyclic ADC processing 3.3 Vpp single-ended rail-to-rail input signals is presented. The proposed ADC demonstrates an offset voltage less than 1 mV without well-known calibration and trimming techniques although power supplies are directly employed as voltage references. The SHA-free input sampling scheme and the two-stage switched op-amp discussed in this work reduce power dissipation, while the comparators based on capacitor-divided voltage references show a matched full-scale performance between two flash sub ADCs. The prototype ADC in a $0.18{\mu}m$ 1P6M CMOS demonstrates the effective number of bits of 11.48 for a 100 kHz full-scale input at 2 MS/s. The ADC with an active die area of $0.12\;mm^2$ consumes 3.6 m W at 2 MS/s and 3.3 V (analog)/1.8 V (digital).

Comparative Analysis of 10 MW Superconducting Wind Power Generators with Three-phase and Nine-phase Armature Windings

  • Kim, Taewon;Woo, Sang-Kyun;Sung, Hae-Jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.343-347
    • /
    • 2019
  • When referring to weight, volume, and efficiency, a SuperConducting Synchronous Generator (SCSG) is definitely superior to conventional generators as a large-scale wind power generation system. The SCSG is connected to a full power converter that transmits the energy from the SCSG to the power grid. To reduce the current stress and system cost, the SCSG which has nine-phase armature windings with three converters is used. This paper deals with a comparative analysis of 10 MW superconducting wind power generators with three-phase and nine-phase armature windings. The stator windings of SCSGs are of various types. Using the finite element method, SCSGs are analyzed and compared in terms of the weight and volume of SCSGs, the total length of the superconducting wire, harmonics, torque performance, and efficiency. The analyzed results will be effectively utilized to design large-scale superconducting generators for wind power generation systems.

Mass-estimation Algorithm by Vibration Response Measurement of Dynamic Balance (동적 저울의 진동응답 측정에 의한 질량 추정 알고리즘)

  • 김병삼
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.71-78
    • /
    • 2000
  • Quickness and precision are the two most important requirements for an industrial scale used in production lines. In this paper, a new approach, "Mass-estimation algorithm by vibration-response measurement of dynamic balance", is presented to improve some of drawbacks in conventional scales. The system, consisted of velocity and displacement sensors, spring scale, analog-digital converter and microcomputer, is based on full utilization of dynamic mass measurement of velocity and displacement via microcomputer-assisted real time monitoring. The resulting system, when combined with appropriate mass estimation algorithm software, has shown its effectiveness in terms of two desirable characteristics required.

  • PDF

Analysis of Effect of Capacitor Voltage Fluctuation Suppression Controller on Natural Arm Capacitor Voltage Balancing of a Direct Modulated MMC (직접 변조 방식 MMC의 전압 맥동 제어기가 암 캐패시터 전압 자연 밸런싱에 미치는 영향 분석)

  • Jung, Jae-Jung;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.385-386
    • /
    • 2016
  • 직접 변조 방식(direct modulation)을 사용한 Modular Multilevel Converter(MMC)의 6개의 암 캐패시터 전압의 자연균형화(Natural Balancing) 현상은 여러 연구 및 실험에서 관측되고 있다. 또한, 이러한 현상의 원리뿐만 아니라, 시스템 파라미터와 밸런싱 동특성사이의 관계가 수학적인 분석을 통하여 검증되었다. 직접 변조 방식은 간접 변조 방식(indirect modulation)과 달리, 입/출력 AC 및 DC 측 제어기 외에 암 캐패시터 전압 밸런싱을 위한 순환전류 제어기가 존재하지 않지만, 캐패시터 맥동 저감을 위해 일반적으로 캐패시터 2 고조파 맥동 제어기를 필요로 한다. 본 논문에서는 이러한 직접 변조방식을 사용한 MMC의 2고조파 전압 맥동 제어기가 암 캐패시터 전압 자연 밸런싱에 미치는 영향을 고찰하고 분석한다. 또한, 2 고조파 전압 맥동 제어기의 유무에 따른 전압 자연 밸런싱의 동특성에 대한 비교를 400MW MMC full-scale 시뮬레이션을 통해 살펴보도록 한다.

  • PDF

Control of a VSC-HVDC Transmission System based on Modular Multilevel Converters (모듈형 멀티레벨 컨버터로 구성된 고압직류 송전시스템의 제어)

  • Cui, Shenghui;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.341-342
    • /
    • 2014
  • VSC-HVDC system based on Modular Multilevel Converter (MMC) is an emerging technology since compared to the conventional VSC-HVDC system an MMC presents several advantages such as modularity, low dv/dt, low harmonics, and low switching losses. In this paper, a comprehensive control strategy of an MMC-based VSC-HVDC system is proposed. In contrast to the conventional system control strategy, the DC side of the MMC operates as a controlled voltage source by the proposed method, and the dynamics of the transmission line voltage and current can be actively controlled. Validity of the proposed strategy was verified by 201-level full-scale computer simulation.

  • PDF

Analysis of Internal Energy Pulsation in MMC System According to Offset Voltage Injection with PWM Methods (PWM 방식을 이용한 옵셋 전압 주입에 따른 MMC 시스템 내부 에너지 맥동 분석)

  • Kim, Jae-Myeong;Jung, Jae-Jung
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1140-1149
    • /
    • 2019
  • In general, there are various pulse width modulation(PWM) methods simply using the offset voltage injection in voltage source converter(VSC). In accordance with the AC side voltage synthesis method with the offset voltage, DC side voltage utilization factor in VSC is changed. Also, this can apply equally to the MMC system. In other words, if the DC side capacity of the high voltage DC(HVDC) transmission system is determined, the maximum reactive power which can be supplied to the AC side can be changed according to the applied output voltage synthesis method with the offset voltage. In this paper, the leg energy pulsation in MMC system according to the AC side output voltage synthesis method with offset voltage which several representative PWM are applied to are mathematically analyzed and compared with each other. Finally, the above results are verified by simulation emulating the 400MVA full-scale MMC system to determine the consistency of the mathematical analysis.

Development of Operation Control and AC/DC Conversion Integrated Device for DC Power Application of Small Wind Power Generation System (소형 풍력발전시스템의 직류전원 적용을 위한 운전제어 및 AC/DC변환 통합장치 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.179-184
    • /
    • 2019
  • In many countries, such as developing countries where electricity is scarce, small wind turbines in the form of Off Grid are an effective solution to solve power supply problems. In some countries, the expansion of power systems and the decline of electricity-intensive areas have led to the use of small wind power in urban road lighting, mobile communications base stations, aquaculture and seawater desalination. With this change, the size of the small wind power industry is expected to have greater potential than large-scale wind power. In the case of small wind power generators, the generator is controlled at a variable speed, and the voltage and current generated by the generator have many harmonic components. To solve this problem, the AC to DC converter to be studied in this paper is a three-phase step-up type converter with a single switch. The inductor current is controlled in discontinuous mode, and has a characteristic of having a unit power factor by eliminating the harmonic of the input current. The proposed converter is composed of LCL filter and three phase rectification boost converter at the input stage and a single phase full bridge for grid connection. It is a control system with energy storage system(ESS) that the system stabilization can be pursued against the electric power.

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

Detection of Blood Agent Gas Using $SnO_2$ Thin Film Gas Sensor

  • Choi, Nak-Jin;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Lee, Duk-Dong;Bahn, Tae-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.69-75
    • /
    • 2004
  • In this study, thin film gas sensor based on tin oxide was fabricated to examine its characteristics. Target gas is acetonitrile ($CH_3$CN) which is a blood simulant for the chemical warfare agent. Sensing materials are SnO$_2$ SnO$_2$/Pt, and Sn/Pt with thickness from 1000 to 3000 $\AA$. The sensor consists of a sensing electrode with inter-digit (IDT) type in front side and a heater in rear side. Resistance changes of sensing materials are monitored on real time basis using a data acquisition board with a 12-bit analog to digital converter. Sensitivities are measured at different operating temperatures also with different gas concentrations and film thickness. The high sensitivity is obtained for Sn (3000 $\AA$)/Pt (30 $\AA$) at 30$0^{\circ}C$ for 3 ppm. Response and recovery times were about 40 and 160 s, respectively. Repetition measurements showed very good results with $\pm$3% in full scale range.

A High Efficiency Power Conversion Circuit with Wide ZVS Range for Large Screen PDP Sustaining Power Module (넓은 영전압 스위칭 범위를 갖는 대화면 PDP용 유지전원단을 위한 고효율 전력 변환회로)

  • Park Kyung-Hwa;Moon Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.578-586
    • /
    • 2005
  • Recently, due to the launch of digital broadcasting service, the demand of Flat Panel Display (FPD) is sharply rising. Among them, the PDP is expected to be one of the most promising digital displays of next generation because of its large screen size, high resolution, thinness and board field of view. Meanwhile, the PDP uses ADS (Address Display-period Separation) scheme which divide one subfield into address and sustaining period to express the grey scale of images. Since the output of sustaining power module Is mostly used for sustaining period, the load of the sustaining power module can be considered as a pulsating load. Due to this particular load condition, if the wide ZVS range of the power switches is not guaranteed, the hard switching causes large amount of switching loss and serious thermal problem in power module. In this paper, a high efficiency power conversion circuit for 60' PDP sustaining power module which achieves wide ZVS range with the help of additional ZVS tank is proposed. According to the various gating methods, the different operations of the proposed converter are presented. And, to confirm the properties of the proposed converter, an experimental prototype of 900W power converter is constructed md tested. As a result, more than $92\%$ of high efficiency is obtained at $10\%$ load condition, and the ZVS operation is achieved from full load to $10\%$ load condition.