• 제목/요약/키워드: Full-Scale Pipe

검색결과 69건 처리시간 0.029초

하드웨어-인-더-루프 기반의 배관 평가 시뮬레이터의 개발 (Development of a Piping Integrity Evaluation Simulator Based on the Hardware-in-the-Loop Simulation)

  • 김영진;허남수;차헌주;최재붕;표창률
    • 대한기계학회논문집A
    • /
    • 제25권7호
    • /
    • pp.1031-1038
    • /
    • 2001
  • In order to verify the analytical methods predicting failure behavior of cracked piping, full-scale pipe tests are crucial in nuclear power plant piping. For this reason, series of international test programs have been conducted. However, full-scale pipe tests require expensive testing equipment and long period of testing time. The objective of this paper is to develop a test system which can economically simulate the full-scale pipe test regarding the integrity evaluation. This system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system was developed for the integrity evaluation of nuclear piping based on the methodology of hardware-in-the-loop (HiL) simulation. Using this simulator, the piping integrity can be evaluated based on the elastic-plastic behavior of full-scale pipe, and the high cost full-scale pipe test may be replaced with this economical system.

Application of cohesive zone model to large scale circumferential through-wall and 360° surface cracked pipes under static and dynamic loadings

  • Moon, Ji-Hee;Jang, Youn-Young;Huh, Nam-Su;Shim, Do-Jun;Park, Kyoungsoo
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.974-987
    • /
    • 2021
  • This paper presents ductile fracture simulation of full-scale cracked pipe for nuclear piping materials using the cohesive zone model (CZM). The main objective of this study is to investigate the applicability of CZM to predict ductile fracture of cracked pipes with various crack shapes and under quasi-static/dynamic loadings. The transferability of the traction-separation (T-S) curve from a small-scale specimen to a full-scale pipe is demonstrated by simulating small- and full-scale tests. T-S curves are calibrated by comparing experimental data of compact tension specimens with finite element analysis results. The calibrated T-S curves are utilized to predict the fracture behavior of cracked pipes. Three types of full-scale pipe tests are considered: pipe with circumferential through-wall crack under quasistatic/dynamic loadings, and with 360° internal surface crack under quasi-static loading. Computational results using the calibrated T-S curves show a good agreement with experimental data, demonstrating the transferability of the T-S curves from small-scale specimen.

흰 광폭평판 시험을 이용한 원자력 배관의 파괴거동예측 (Prediction of Failure Behavior for Nuclear Piping Using Curved Wide-Plate Test)

  • 허남수;김윤재;최재붕;김영진;임혁순;정대율
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.352-361
    • /
    • 2004
  • One important element of the Leak-Before-Break analysis of nuclear piping is how to determine relevant fracture toughness (or the J-resistance curve) for nonlinear fracture mechanics analysis. The practice to use fracture toughness from a standard C(T) specimen is known to often give conservative estimates of toughness. To improve the accuracy, this paper proposes a new method to determine fracture toughness using a nonstandard testing specimen, curved wide-plate in tension. To show validity of the proposed curved wide-plate test, the J-resistance curve from the full-scale pipe test is compared with that from the curved wide-plate test and that from the C(T) specimen. It is shown that the J-resistance curve form the curved wide-plate tension test is similar to, but that from the C(T) specimen is lower than, the J-resistance curve from the full-scale pipe test. Further validation is performed by investigating crack-tip constraint conditions via detailed 3-D FE analyses, which shows that the crack-tip constraint condition in the curved wide-plate tension specimen is indeed similar to that in the full-scale pipe under bending.

원주방향 노치형 감육부를 가진 배관의 손상거동 평가 (Evaluation of Failure Behavior of a Pipe Containing Circumferential Notch-Type Wall Thinning)

  • 김진원;박치용
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1295-1302
    • /
    • 2003
  • In order to evaluate a failure behavior of pipe with notch-type wall thinning, the present study performed full-scale pipe tests using the 102mm, Schedule 80 pipe specimen simulated notch- and circular-type thinning defects. The pipe tests were conducted under the conditions of both monotonic and cyclic bending moment at a constant internal pressure of 10 MPa. From the results. of experiment the failure mode, load carrying capacity, deformation ability, and fatigue life of a notch-type wall thinned pipe were investigated, and they were compared with those of a circular-type wall thinned pipe. The failure mode of notched pipe was similar to that of circular-type thinned pipe under the monotonic bending load. Under the cyclic bending load, however, the mode was clearly distinguished with variation in the shape of wall thinning. The load carrying capacity of a pipe containing notch-type wall thinning was about the same or slightly lower than that of a pipe containing circular-type wall thinning when the thinning area was subjected to tensile stress, whereas it was higher than that of a pipe containing circular-type thinning defect when the thinning area was subjected to compressive stress. On the other hand, the deformation ability and fatigue life of a notch-type wall thinned pipe was lower than those of a circular-type wall thinned pipe.

실제크기 배관의 파열시험을 통한 가스배관의 파괴거동 평가 (The Evaluation of Remaining Strength for Corroded Pipeline by Full Scale Burst Test)

  • 김영표;백종현;김우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.339-344
    • /
    • 2001
  • The transmission pipeline industry spends many millions of dollars annually performing inline inspections, excavating sites of possible corrosion, and repairing or replacing damaged sections of pipe. New criteria for evaluation the integrity of corroded pipe have been developed in recent years to help in controlling these costs. These new criteria vary widely in their estimates of integrity and the most appropriate criterion for a given pipeline is not always clear. This paper presents an overview, comparison and evaluation of acceptability criteria for corrosion defects in pipelines. By full scale burst tests, this paper have assessed the relative accuracy of each of theses criteria in predicting failure and remaining strength. Many of the criteria appear to be excessively conservative and indicate that defects must be repaired when none is needed, based upon burst test data.

  • PDF

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

원형강관으로 보강된 지중매립형 FRP 개인하수 처리시설의 설계 (Design of High Strength Underground FRP Septic Tank Stiffened by Circular Steel Pipe)

  • 조광제;김성보
    • 대한토목학회논문집
    • /
    • 제32권3A호
    • /
    • pp.171-181
    • /
    • 2012
  • 지중에 매설된 원형강관으로 보강된 FRP 개인하수 처리시설에 대한 설계를 수행하고 실물 현장 재하실험을 통하여 보강의 형태 및 종류에 따른 극한거동을 분석하였다. 현행 개인하수 처리시설의 설계 기준의 문제점 파악하고 강관으로 보강된 하수처리시설에 대한 구조설계절차를 정립하였다. 본체 두께 및 보강링, 격벽을 고려한 제품을 설계하고 안전성을 검토하였다. 원통형 쉘의 구조재료로 사용되는 박막의 FRP에 대해 휨실험과 인장실험을 수행하여 재료특성을 파악하였다. 개인하수처리시설을 무보강, 강재 보강링 보강, 격벽 보강으로 설계한 제품의 현장실험을 통하여 본체의 변위와 응력의 변화를 계측 하여 파괴거동을 분석하였고 유한요소해석 결과와 비교, 검토하였다.

실배관 파열시험을 통한 부식배관의 파열압력 평가 (The Evaluation of Burst Pressure for Corroded Pipeline by Full Scale Burst Test)

  • 김영표;백종현;김우식;고영태
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.203-210
    • /
    • 2002
  • The transmission pipeline industry spends many millions of dollars annually performing inline inspections, excavating sites of possible corrosion, and repairing or replacing damaged sections of pipe. New criteria fur evaluation of the integrity of corroded pipe have been developed in recent years to help in controlling these costs. These new criteria vary widely in their estimates of integrity and the most appropriate criterion fur a given pipeline is net always clear. This paper presents an overview, comparison and evaluation of acceptability criteria for corrosion deflects in pipelines. By full scale burst tests, this paper has assessed the relative accuracy of each of theses criteria in predicting burst pressure. Many of the criteria appear to be excessively conservative and indicate that deflects must be repaired when none is needed, based upon burst test data.

성토지지말뚝의 지하매설관 측방이동 방지효과 (Effect of Embankment-Pile on Preventing Lateral Movement of Buried Pipe)

  • 김재홍;홍원표
    • 한국지반공학회논문집
    • /
    • 제30권12호
    • /
    • pp.63-72
    • /
    • 2014
  • 측방유동 지반 속에 설치된 매설관의 측방이동과 이에 대한 성토지지말뚝의 방지효과를 관찰하기 위하여 일련의 현장 실험시공을 시행하였다. 매립중인 서해안 연약지반에 지하매설관(H.P:400mm)를 부설하고 인접 위치에 성토를 3단계로 시행하여 침하판과 지중경사계를 이용하여 지하매설관의 수직변위(침하)와 수평변위를 확인하였다. 성토에 따른 측방유동 억지대책으로는 성토지지말뚝을 설치하였다. 실험시공 결과 성토도중에는 매설관이 미미하게 융기하는 현상이 발생하였고 추후 침하하다 점차 수렴하는 거동으로 나타났다. 성토지지말뚝 보강 효과는 약 2.0배로 확인되었다. 또한, 침하와 변위는 상부지반에서는 크고 하부지반에서는 적게 침하가 발생하였고 변위는 비례하여 발생하는 것으로 나타났다.