• 제목/요약/키워드: Full scale experiment

검색결과 237건 처리시간 0.023초

스팬드럴 부분 BIPV창호 적용 및 후면마감재 구성에 따른 온도특성 분석 연구 (The Evaluation of the Temperature Characteristics at the Spendrels of Curtain wall with a-Si BIPV Window System)

  • 김동수;오명환;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.165-170
    • /
    • 2012
  • This study aims to analyze the characteristics of temperature variation of Spandrels. According to the change of SHGC of Window system, air space, insulation performance and absorption factor of inner surface at the Spandrels, It was firstly estimated by using simulation. Secondly, measured to minimize the temperature-rise of inner surface temperature and the intermediate air temperature by using Full-scale Mock-up based on the result of simulation analysis. As a result, it turns out that low SHGC window system such as BIPV system had an advantage of reducing the window surface temperature, and the surface temperature of clear window system was all higher than BIPV system on simulation results. In the experiment results, it had some advantages of increasing the Spandrels volume, decreasing insulation performance and lower absorption factor.

  • PDF

의복범주가 젊은이의 대인지각에 미치는 영향 -유행성 및 착용자의 체형과 관련지어- (The Effect of Garment Category, Fashionability and Wears' Body type on Impression Formation)

  • 김재숙;김희숙
    • 한국의류학회지
    • /
    • 제16권4호
    • /
    • pp.371-377
    • /
    • 1992
  • The purposes of the study were 1) to extend the cognitive categorization theory in an attempt to explain the of garment category, fashionability, and wearer's body types on impression formation, and 2) to find out structures of wearer's impressional dimension and wearer's professional image. The research included a quasi-experiment and survey. The experimental design was a $2^{3}$full factorial design of 3 independent variables. The experimental materials developed for the study were a set of stimuli and a response scale. The stimuli consisted of 8 drawings made by 3 independent variables (garment category, fashion level, wearer's body type). Result were as follows: 1) Garment category, fashionability and wearer's body type had significant effects on impression of the 5 factors-evaluation, potency, appearance, sociability and good-bad, with exception of wearer's body type which was nonsignificant to the potency factor. 2) Garment category was most effective on the evaluation and the potency. However wearer's body type was most effect on the appearance factor and fashionability variable was most effective on the good-bad factor. It was conclued that the results supported the cognitive categorization theory on impression formation and a cognitive categorization hypothesis of clothes.

  • PDF

궤도 차량용 물 분사 추진 장치의 임펠러 직경 변화에 따른 성능 비교 (Comparison of Waterjet Performance for Tracked Vehicle according to the Variation of Impeller Diameter)

  • 김현열;김문찬;전호환
    • 대한조선학회논문집
    • /
    • 제41권5호
    • /
    • pp.21-27
    • /
    • 2004
  • A waterjet propulsion system has many advantages compared with a conventional screw propeller especially for amphibious military vehicles because of a good maneuverability at low speed, good operating ability at shallow water, high thrust at low speed to aid maneuverability and exit from water, etc. Especially, compact design is important for the tracked-vehicle because of buoyancy in water and available space inside the tracked vehicle. The experiment is parametrically performed for various impeller diameters for more compact design. The experimental results are analyzed according to the ITTC 1996 standard analysis method as well as the conventional propulsive factor analysis method. The full-scale effective and delivered power of the tracked-vehicle are evaluated according to the variation of impeller diameter. This paper emphasized the effect of impeller diameter on the performance of waterjet system.

P.C 대형판 부분구조의 비선형 거동에 관한 실험과 해석 비교연구 (Study on the Correlation between Analysis and Experiment for the Nonlinear Behavior of large Panel Precast Concrete Subassemblage)

  • 김성호;이한선;이병해
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.47-54
    • /
    • 1990
  • 접합부에서 급격한 불연속성을 가진 프리캐스트 콘크리트(P.C) 대형판 구조는 붕괴에 이르기까지의 구조적인 거동이 일체식 콘크리트 구조와 매우 상이하다. 또한 극심한 지진과 같은 횡하중이 작용할 경우 그 최대 붕괴하중과 붕괴청상을 파악하는 것은 매우 중요한 과제이다. 본 연구에서는 2층 실물크기 P.C 시험체에 대한 정적 실험결과를 토대로 비선형 해석 전산 프로그램인 ANSR를 사용하여 P.C 구조물의 비선형 거동을 예측하고 실험에서 관찰할 수 없는 최종 붕괴시까지의 내부 응력의 분포 및 변화를 연구하였다.

  • PDF

혼합 산업폐수의 질소제거를 위한 외부 탄소원 투입과 물질수지: 실증실험 (Nitrogen Removal from a mixed Industrial Wastewater using Food-Waste Leachate and Sugar Liquid Waste as External Carbon Sources: Full-Scale Experiment)

  • 이몽학;안조환;이정훈;배우근;심호재
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.663-668
    • /
    • 2012
  • The feasibility of enhancing biological nutrient removal from an industrial wastewater was tested with food waste leachate and sugar liquid waste as external carbon sources. Long term influences of adding external carbon sources were investigated to see how the biological nutrient removal process worked in terms of the removal efficiency. The addition of the external carbons led to a significant improvement in the removal efficiency of nutrients: from 49% to approximately 76% for nitrogen and from 64% to around 80% for phosphorus. Approximately, 20% of the removal nitrogen was synthesized into biomass, while the remaining 80% was denitrified. Though the addition of external carbon sources improved nutrient removal, it also increased the waste sludge production substantially. The optimal observed BOD/TN ratio, based on nitrogen removal and sludge production, was around 4.0 in this study.

Flexural Behavior of High-Strength Concrete Beams Confined with Stirrups in Pure Bending Zone

  • Jang, Il-Young;Park, Hoon-Gyu;Kim, Yong-Gon;Kim, Sung-Soo;Kim, Jong-Hoe
    • International Journal of Concrete Structures and Materials
    • /
    • 제3권1호
    • /
    • pp.39-45
    • /
    • 2009
  • The purpose of this study is to establish flexural behavior of high-strength concrete beams confined in the pure bending zone with stirrups. The experiment was carried out on full-scale high-strength reinforced concrete beams, of which the compressive strengths were 40 MPa and 70 MPa. The beams were confined with rectangular closed stirrups. Test results are reviewed in terms of flexural capacity and ductility. The effect of web reinforcement ratio, longitudinal reinforcement ratio and shear span to beam depth ratio on ductility are investigated. The analytic method is based on finite element method using fiber-section model, which is known to define the behavior of reinforced concrete structures well up to the ultimate state and is proven to be valid by the verification with the experimental results above. It is found that confinement of concrete compressive regions with closed stirrups does not affect the flexural strength but results in a significantly increased ductility. Moreover, the ductility tends to increase as the quantity of stirrups increases by reducing the spacing of stirrups.

Drift displacement data based estimation of cumulative plastic deformation ratios for buildings

  • Nishitani, Akira;Matsui, Chisa;Hara, Yushiro;Xiang, Ping;Nitta, Yoshihiro;Hatada, Tomohiko;Katamura, Ryota;Matsuya, Iwao;Tanii, Takashi
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.881-896
    • /
    • 2015
  • The authors' research group has developed a noncontact type of sensors which directly measure the inter-story drift displacements of a building during a seismic event. Soon after that event, such seismically-induced drift displacement data would provide structural engineers with useful information to judge how the stories have been damaged. This paper presents a scheme of estimating the story cumulative plastic deformation ratios based on such measured drift displacement information toward the building safety monitoring. The presented scheme requires the data of story drift displacements and the ground motion acceleration. The involved calculations are rather simple without any detailed information on structural elements required: the story hysteresis loops are first estimated and then the cumulative plastic deformation ratio of each story is evaluated from the estimated hysteresis. The effectiveness of the scheme is demonstrated by utilizing the data of full-scale building model experiment performed at E-defense and conducting numerical simulations.

Fire resistance of high strength concrete filled steel tubular columns under combined temperature and loading

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • 제27권2호
    • /
    • pp.243-253
    • /
    • 2018
  • In recent years, concrete-filled box or tubular columns have been commonly used in high-rise buildings. However, a number of fire test results show that there are significant differences between high strength concrete (HSC) and normal strength concrete (NSC) after being subjected to high temperatures. Therefore, this paper presents an investigation on the fire resistance of HSC filled steel tubular columns (CFTCs) under combined temperature and loading. Two groups of full-size specimens were fabricated to consider the effect of type of concrete infilling (plain and reinforced) and the load level on the fire resistance of CFTCs. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The results demonstrate that the higher the axial load level, the worse the fire resistance. Moreover, in the bar-reinforced concrete-filled steel tubular columns, the presence of rebars not only decreased the spread of cracks and the sudden loss of strength, but also contributed to the load-carrying capacity of the concrete core.

전단보강에 따른 일방향 중공슬래브의 휨 성능 평가 (Evaluation on Flexural Performance of One-Way Hollow Slabs according to the Shear Reinforcement)

  • 유유진;석근영;김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제14권2호
    • /
    • pp.79-86
    • /
    • 2014
  • The purpose of this study is intended to determine the validity of shear reinforcement by evaluating flexural performance in the hollow slab. The hollow slab is relatively light and second moment of inertia is large. Due to these characteristics, it can be used to slab system efficiently. Therefore the prediction of the structural behaviors is very important because of decrease of shear and flexural strength which is caused by hollow section of slab interior. In this study, the flexural test were performed to analyze the flexural capacity of the hollow slab w/ or w/o shear reinforcement. A total of six full scale specimens were tested. These specimens have three cases of reinforcing bar ratio, 0.009, 0.018 and 0.024. To verify the flexural behavior such as ultimate load, load-deflection and crack pattern, the flexural experiment were tested by using loading frame. Experimental results have shown that the flexural behavior are depend on the reinforcing bar ratio. Also the hollow slab with shear reinforcement have shown flexural behavior. Therefore, it is appropriate that the hollow slab is reinforced by shear reinforcement to improve the flexural performance of the hollow slab.

현장타설형 건물 기초를 이용한 지중열 공조시스템의 성능평가에 관한 연구 (A Study on Development of a Ground-Source Heat Pump System Utilizing Cast-in-place Concrete Pile Foundation of a Building)

  • 황석호;남유진
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.641-647
    • /
    • 2010
  • Ground-source(Geothermal) heat pump(GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump(ASHP) systems. However, GSHP systems are not widespread because of their expensive installation costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a full-scale experiment. As a result, the average values for heat rejection were 186~201 W/m(per pile, 25 W/m per pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems.