• Title/Summary/Keyword: Fuel-staging

Search Result 28, Processing Time 0.029 seconds

The Characteristics of Pulverized Coal Combustion in the Two Stage Cyclone Combustor

  • Joo, Nahm-Roh;Kim, Ho-Young;Chung, Jin-Taek;Park, Sang-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1112-1120
    • /
    • 2002
  • Numerical investigations on air staging and fuel staging were carried out with a newly designed coaxial cyclone combustor, which uses the method of two stage coal combustion composed of pre-combustor and main combustor. The pre-combustor with a high air/fuel ratio is designed to supply gas at high temperature to the main combustor. To avoid local high temperature region in this process, secondary air is injected in the downstream. Together with the burned gas supplied from the pre-combustor and the preheated air directly injected into main combustor, coals supplied through the main burner react rapidly at a low air/fuel ratio. Strong swirling motion of cyclone combustor keeps the wall temperature high, which makes slagging combustion possible. Alaska, US coal is used for calculations. Predictions were made for various coal flow rates in the main combustor for fuel staging and for the various flow rate of secondary air in the pre-combustor for air staging. In-scattering angles are also chosen as a variable to increase residence times of coal particles. Temperature fields and particle trajectories for various conditions are described. Predicted temperature variations at the wall of the combustor are compared with corresponding experimental data and show a similar trend. The in-scattering angle of 20° is recommended to increase the combustion efficiency in the main chamber.

A Basic Study of Fuel 2-staging Y-jet Atomizer to Reduce NOx in Liquid Fuel Burner (액체 연료용 버너에서 NOx 저감을 위한 연료2단 분사 Y-jet 노즐에 관한 기초연구)

  • Song, Si-Hong;Lee, Gi-Pung;Kim, Hyeok-Je;Park, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1616-1623
    • /
    • 2001
  • A basic experimental study has been carried out to find out the design parameters of fuel 2-staging atomizers in order to reduce nitrogen oxides(NOx) rate emitted from the steam boilers used the liquid fuel. The heavy fuel oil(B-Coil) and fuel 2-staging Y-jet twin-fluid atomizers were adopted in this study. The results of this paper were obtained from the real as well as the model scale atomizers. In the case of model atomizers test, NOx reduction rate was strongly dependent on the staged fuel rate, but it was weakly dependent on the injection hole arrangement and air swirl conditions. The real scale atomizers was designed and manufactured on the base of these test results, and those was mounted and operated in the real boiler generates 185 ton steam per an hour. The reduction rate of the model and real plant was reached 10∼30% of base NOx by atomizers. but dust was sharply increased in the low O$_2$combustion region of the real plant.

An Experiment on Low NOx Combustion Characteristics in a Multi-Staged Burner (다단연소기를 이용한 저 NOx 연소특성 연구)

  • Cho, Eun-Seong;Sung, Yong-Jin;Chung, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.32-38
    • /
    • 2003
  • Staged combustion, such as air- and fuel-staging, is a relatively well-known technique fur reduction of NOx emission and used in combination with other techniques nowadays. However, the design variables are still selected depending upon operating conditions. There are many variables tested to investigate the NOx emission characteristics fur changing of fuel or air velocity, swirl intensity, and staging ratio of air and fuel in multi-staged burner. In air-staging case, the fuel-rich condition of the primary combustion zone is very helpful to reduce NOx emission and its range is known to be restricted by the increase of carbon monoxide. However, in many cases carbon monoxide level is not too high to be restricted operating condition. So we tried to expand the equivalence ratio range to the richer condition in the primary combustion zone and certificate the function of each burner component and its contribution to the overall NOx production.

Experimental Investigation of NOX Reduction using a Hybrid Fuel Lean Reburning System (NOx 저감을 위한 하이브리드 연료희박 재연소 연구)

  • Kim, Hak-Young;Baek, Seung-Wook;Hwang, Chang-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The main goal of this study is to examine the use of a hybrid -fuel lean reburning system with air staging for $NO_X$ reduction. The experimental variables include the reburn fuel fraction, sizes of reburn- fuel-injection nozzles, oxygen enrichment ratio, and location of reburn- fuel- injection. The effect of the flow field induced by air- staging combustion on $NO_X$ reduction is considered, and then, the $NO_X$ reduction rate is compared with only fuel lean reburning system. On the basis of the effectiveness of each De-$NO_X$ process, the advantage of using the hybrid reburning system with air staging is determined and discussed.

Effect of Lean-rich Fuel Staging to the Multiple Jet Flames on the Blowout Velocity (과농-희박연료가 교차로 공급되는 상호작용 화염의 화염날림에 관한 연구)

  • Lee, Byeong-Jun;Park, Kyung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.1
    • /
    • pp.7-14
    • /
    • 2008
  • It has been reported that partially premixed interacting flame could be sustained till sonic exit velocities if eight small nozzles are arranged optimally and one nozzle on the center is fed small amount of fuel. But the equivalence ratios in this experiments were 20-60. In this research, experiments were conducted to know the effects of lean-rich staging in multiple jet flames on the blowout velocity. The fuel mole tractions in the fuel-air mixture, the nozzle exit velocity and the diameter between adjacent nozzles were alternatively changed. When the lower mole fraction fuel was fed to the nozzles located near the center and small amount of fuel to the center nozzle, flame was not extinguished even at the nozzle exit velocity of 200m/s. Also the interacting flame could be sustained till that velocity when four small size nozzles for lean mixture were located within the arrangement of four nozzles for rich mixture and configured optimally.

Reduction of Nitrogen Oxides from Fuel Nitrogen in New Fuelling System

  • 전영남;채재우
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.10
    • /
    • pp.885-892
    • /
    • 1996
  • The effects of NOx reduction by advanced fuel staging in a small scale combustor (6.6 kWT) have been investigated using propane gas flames laden with ammonia as fuel-nitrogen. The variables which had the greatest influence on NOx reduction were temperature, reducing stoichiometry (relate to main combustion zone stoichiometry, air fraction and reburning fuel fraction) and residence time of reducing zone. NOx reduction was best at the reburning zone temperature of above 1,000 ℃ and reburning zone stoichiometry was 0.85. In terms of residence time of the reburning zone, NOx reduction was effective when burnout air was injected at the point where the reburning zone had been already established. In the advanced fuel staging NOx reduction was relatively large at the burning of higher Fuel-N concentration in the fuel. Under optimum reburning conditions, fuel nitrogen content had a relatively minor impact on reburning efficiency.

Characteristics of UBC and NOx Emission in Air Staging Combustion (공기 다단 연소 기법 적용에 따른 미연탄소분 및 질소산화물 배출특성)

  • Kim, Jeong Woo;Lim, Ho;Go, Young Gun;Jeon, Chung Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.637-644
    • /
    • 2016
  • The purpose of this study is to understand the characteristics of unburned carbon (UBC) and NOx emissions for pulverized coal when air staging combustion is applied. A two-staged drop tube furnace capable of applying air staging combustion was designed and installed. The combustion of sub-bituminous (Tanito) has been investigated. UBC and the NOx concentration were measured under various temperatures and stoichiometric ratios in unstaged and staged combustion. As a result, UBC decreased and the NOx concentration increased with an increase in stoichiometric ratio and temperature. In particular, the NOx reduction mechanism was activated when the temperature in the fuel rich zone increased. Both UBC and the NOx concentration decreased as the temperature increased in the fuel rich zone. A high NOx reduction effect was obtained, compared to the UBC increase, when the air staging technique was applied.

NO Reduction and High Efficiency Combustion by Externally Oscillated Staging Burner

  • Lim, Mun-Sup;Yang, Won;Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.158-163
    • /
    • 2009
  • It is difficult for a burner to achieve an increase in combustibility and a reduction of NOx emission, simultaneously. The reason is because thermal NOx could be reduced at low temperature, while the combustibility should be decreased. To solve this problem, an externally oscillated staging burner was developed, and experiment was conducted according to effective parameters. The combustibility could be improved through the accelerated transfer of heat, mass and momentum obtained by external oscillation. Also, NO is reduced by the decrease of residence time of burning gas in the local highest-temperature spot, which is decreased by the external oscillation and fuel staging. Experiments on variables were conducted to determine the reference flame, and the flame generating the lowest NO concentration was selected. The conditions of reference flame were oscillation frequency 250 Hz, sound pressure 1 VPP, and air ratio 1.1, and NO and CO concentrations were 1ppm and 20 ppm, respectively.

Effect of Air Staging on NOx Reduction in Pulverized Coal Combustion (미분탄 연소에서 NOx 저감을 위한 공기다단의 효과)

  • Jang, Gil-Hong;Chang, In-Gab;Sun, Chil-Young;Chon, Mu-Hwan;Yang, Gwan-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.149-154
    • /
    • 1999
  • The influences of air staging on NOx emission and burnout of coal flames were investigated using 1MWth combustion test facility. The experiments showed that variation of overall excess air ratio led to a relatively higher NOx emission level for ${\lambda}=1.2.$ When air staging was applied to the combustion air, it was confirmed that a fuel rich primary combustion zone was established and unburned char was burened completely by mixing with the staged air supplied radially around the flame. The NOx emissions were redued by increasing the staged air flow rate, and staging air was suggested to be more than 40% of the total combustion air for the substantial NOx reduction.

  • PDF

$NO_x$ Control by Flue Gas Recirculation in Pulverized Coal Combustion (미분탄 연소에서 배기가스 재순환에 의한 질소산화물 제어)

  • 장길홍;장인갑;선칠영;천무환;양관모
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.473-474
    • /
    • 1999
  • 일반적으로 NOx배출은 연소과정에 의해 강력하게 지배되고 있으며, NOx 저감 기술은 1970년대 후반부터 많은 연구들이 수행되어, 그 이론들이 확립되고 있다. 석탄 연소시스템에서는 공기 다단(air staging, OFA), 연료다단(fuel staging, reburning) 및 배기가스 재순환(FGR) 등이 대표적인 NOx 저감 기술이며 [1∼4], 그 중 배기가스 재순환법은 저산소 배기가스를 연소용 공기에 재혼입시키므로써 NO의 생성속도를 저하시켜 NOx를 저감시키는 기법이다.(중략)

  • PDF