• Title/Summary/Keyword: Fuel-saving

Search Result 280, Processing Time 0.027 seconds

COMPUTER SIMULATION OF TRACTOR PERFORMANCE WITH REGARD TO ENERGY SAVING AND POLLUTION REDUCING

  • Zou, Cheng;Sakai, Jun;Nagata, Masateru
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1110-1116
    • /
    • 1993
  • A study on optimum operation performances of power efficiency, economy and exhaust emissions for a tractor was conducted. A mathematical model of multiple degree polynomial equation was applied to established the function of solid multiple parameter curves for specific fuel consumption (ge), cabon monoxide (CO) ,hydrcarbons (HC) and cabonaceous smoke (Rb). The optimum operation theorems for economy operation indicated by ge and for exhaust emissions described by Co , HC and Rb were obtained from analytical method and performance test data. The optimum operation theorems could exhibit optimum operation working points, curves, and regions. The optimum matching relations of engine speed and transmission parameters were analyzed by using computer simulation methods in accordance with the tractor specifications , actual farm working conditions in a typical drawbar pull work such as plowing , the optimum operation objective function, the ideal transmission ratio, practical gear shif ing positions and practical travel speed of the tractor TN55 medel. The results of the anlayzes indicated clearly that the optimum power efficient operation, energy saving and pollution reducing would be realized if the tractor would be operated according to theoptimum operation methods.

  • PDF

Traffic Signal Timing at Interconnected and Semi-Protected-Left-Turn Intersections for Energy Saving (에너지절약을 위한 상호련결된 반보호좌회전 교차로의 신호시간설계)

  • 김경환
    • Journal of Korean Society of Transportation
    • /
    • v.8 no.1
    • /
    • pp.25-40
    • /
    • 1990
  • This study was undertaken to develop a traffic signal timing method for interconnected and semi-protected-left-turn intersections(the intersections which have left-turn signal but not exclusive left-turn lanes) on four-lane streets for energy saving and to computerize the method for the practical use. For this study, a probability model which could estimate the utilized time of the shared left-turn lane by through traffic during green period was developed based on field studies. The two left-turn treatments, leading and lagging left-turns, were tested for the intersections, and it can be concluded that the leading left-turn was more efficient for the normal urban streets on which through traffic is major traffic. Adopting the leading left-turn macro-models to estimate vehicular average delay and proportions of vehicles stopped at the intersections were developed. Using the two models as well as the idling fuel consumpution rate and the excess fuel consumption per stop-go speed change, a traffic signal timing method for the intersections for energy saving was developed and computerized. The method can be used for more than four-lane streets and for other measures of effectiveness such as minimum delay, minimum stop rates, etc.

  • PDF

A Study on Pilots' Behavior on Decision of Maneuvering Aircraft for Fuel Efficient Flight Operation

  • Yoo, Kwang Eui;Jeon, Seung Joon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.27 no.4
    • /
    • pp.96-104
    • /
    • 2019
  • The response to climate change of international air transport industry might be initiated by ICAO's CORSIA (Carbon Offsetting and Reduction Scheme for International Aviation) which will impact on international airlines' flight operation behavior in the future. Though the airlines' efforts to reduce fuel consumption has been a major issue in economics of aviation industry, the improvement of fuel efficiency in flight operation will have additional impact on their profitability by introducing carbon emission cost. The fuel consumption in flight operation will be somewhat influenced by pilots' technical action for maneuvering aircraft during flight operation. This study will investigate pilots' behavior on decision for tactical aircraft control for mission flight. The data will be collected by the survey through sample pilots asking about their intention and perception on fuel savings during flight operations. The data will be analyzed by AHP process and the study will find out the elements and factors influencing pilots' behavior on technical decision of flight and their weights on fuel saving effects.

Development of Hybrid Excavator for Regeneration of Boom Potential Energy (작업장치 위치에너지 회생을 위한 하이브리드 굴삭기 시스템 개발)

  • Yoon, J.I.;Ahn, K.K.;Truong, D.Q.;Kang, J.M.;Kim, J.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • Nowadays with the high fuel prices, the demands for energy saving and green emission of construction machinery have highly been increased without sacrifice of working performance, safety and reliability. The aim of this paper is to propose a new energy saving hybrid excavator system using an electro-hydraulic actuator driven by an electric motor/generator for the regeneration of potential energy. A 5 ton class excavator is analyzed, developed with the boom for the evaluation of the designed system. The hardware implementation is also presented in this paper. A control strategy for the hybrid excavator is proposed to operate the machine with a highest efficiency. The energy saving ability of the proposed excavator is clearly verified through simulation and experimental results in comparison with a conventional hydraulic excavator.

  • PDF

Construction Equipment Fleet Optimization for Saving Fuel Consumption (에너지 절감을 위한 건설장비 조합 최적화 방법 연구)

  • Yi, Chang-Yong;Lee, Hong-Chul;Lee, Dong-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.198-199
    • /
    • 2015
  • Construction equipment is a major energy consumption source in construction projects. If 10% reduction of the diesel fuel usage is achieved in the construction industry, it may reduce 5% of the total energy usage. Energy saving operation is a major issue in equipment-intensive operations (e.g., earthmoving or paving operations). Identifying optimal equipment fleet is important measure to achieve low-energy consumption in those operations. This study presents a system which finds an optimal equipment fleet by computing the low-energy performance of earthmoving operations. It establishes construction operation model and compares numerous combinations using alternative equipment allocation plans. It implements sensitivity analysis that facilitates searching the lowest energy consumption equipment fleet by enumerating all cases.

  • PDF

The Technology Applied 3 Liter House, Super Energy Saving Building (3L House의 설계, 시공 및 평가)

  • Park, Sun-Hyo;Park, Yong-Seung;Won, Jong-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.814-819
    • /
    • 2006
  • This research is on the design and introducing of integrated thermal performance of super energy saying building, called 3 Liter house which can be sustained with 3 liter oil(kerosene) per $yr.m^2$. 3 liter houses(Passive houses) offer extended living comfort with only 15 to 20% of the space heating demand of conventional new building. To achieve this purpose, the efficiency of building components is improved, such as walls, windows or ventilation system and the construction technology is improved, such as the prevention of thermal bridge and the air tightness. The fuel cell is used as alternative energy. Energy consumption of 3L house is 2.08 [liter/$yr.m^2$] in monitoring result of $2006/2/1{\sim}2/7$ and ACH50 is 0.67 in result of Blow Door Test, therefore 3L House is well- insulated and well- airtighted house.

  • PDF

An Ultrasonic Breaking Action on the Homogeneous Effect of Marine Oil Particles (선박유류 입자의 균질효과에 미치는 초음파 분쇄작용)

  • 이진열;하만식;한원희
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.5 no.2
    • /
    • pp.67-78
    • /
    • 1999
  • Recently, a greater part of all ship use a coarse heavy fuel oil(HFO) over specific gravity(S.G) 1.00/15$^{\circ}C$ and viscosity 3,500 cSt/4$0^{\circ}C$ as the fuel oil of marine boiler or internal combustion engine from the viewpoint of economical ship' operation. The greater plan to improve a combustion methods of heavy fuel oil, such as atomization, homogeneity and emulsification, were contrived and carried out newly, and then applied 20kHz ultrasonic homogenizer to one of test methods. Also, adopted the marine oils(fuel oil and lubricating oil etc.) and sludge oil as test solutions, and its matrix structures were examined with photographs, Especially, it is important at control system of oil pollution, for the sludge oil emulsified, to be recycled as fuel oil of boiler according to 20kHz Ultrasonic homozenizer, and then fuel saving is attained effectively by making sludge oil to be burnt.

  • PDF

Feasibility Study on Thermal Power Plant Condenser Heat Recovery for District Heating and Fuel Line Preheating (발전소 복수기 배열회수의 지역난방 및 연료라인 예열용 활용타당성 검토)

  • Jung, Hoon;Hwang, Gwang-Won
    • New & Renewable Energy
    • /
    • v.5 no.3
    • /
    • pp.40-48
    • /
    • 2009
  • Recovered heat has been considered as a renewable energy in Europe since 2008 because its great effect on energy saving and carbon decreasing in plant process. Energy saving and decreasing green gas are critical issue today, so various technologies to save energy and decrease carbon dioxide in plant process have been applied to many industrial area. In this paper, the feasibility of condenser heat recovery by heat pump in power plant for district heating and fuel line preheating were reviewed by verifying energy (heat) balance and mass balance of power plant model. Some ways to compose proper system to recover heat of condenser are suggested and their possibilities are also reviewed. Limitations on heat recovery in power plant are also reviewed. The results are verified by calculating input/output energy based on actual performance test data of Taean Thermal Power Plant in Korea. There is noticeable improvement of plant performance in some cases which demand low temperature (<100 C) heat like distrcit heating, fuel line heating, and so forth.

  • PDF

Estimation of CO2 Reduction by Applying Idling Stop to in-Use Vehicles (운행자동차의 공회전 정지에 의한 CO2 저감량 산출 연구)

  • Shim, Moo-Kyung;Rim, Jay-Myoung;Lee, Beom-Ho;Hong, Sung-Tae;Lee, Dae-Yup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.10
    • /
    • pp.748-756
    • /
    • 2009
  • The effect of idling stop on $CO_2$ reduction was estimated, especially in the area of in-use vehicles. In order to know the fuel saving for each class of vehicles, a methodology to calculate the fuel saving was used along with a standard test using NIER-07 mode. Idling stop execution rate was estimated by analyzing the driving pattern of the in-use city buses, which shows about 75% at maximum. And this corresponds to about 5.4% reduction of the daily total fuel consumption. Finally, $CO_2$ reduction in the automotive sector was estimated, which concludes that, when idling stop device is used, about 480 thousand and 450 thousand tons of $CO_2$ could be reduced with in-use city buses and taxis, respectively. This amount corresponds to about 1.2% of $CO_2$ reduction in the automotive sector.

Economic analysis on development of low-carbon gear for anchovy boat seine (탄소저감형 권현망어구 개발의 경제성 분석)

  • Park, Seong-Wook;Lee, Kyounghoon;Kang, Min-Joo;Park, Seong-Kwae;Lee, Chun-Woo;Lee, Jihoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.3
    • /
    • pp.291-300
    • /
    • 2013
  • The main purpose of this study is to analyse economic feasibility of low-carbon-oriented gear for anchovy boat seine. The results of benefit/cost analysis showed that use of the low-carbon fishing gear is economically feasible. Considering the fuel saving and relatively low $CO_2$ emission by reducing the resistance of gear, net present value by such type 1 gear improvement was estimated about -2,490 ~ -1,580 million won with the benefit-cost ratio 0.81~ 0.88. And net present value by such type 2 gear improvement was estimated about 6,540 ~ 7,780 million won with the benefit-cost ratio 1.79 ~ 1.94. Development of lowcarbon trawl gear would render significant contributions to reducing $CO_2$ emission in fishing operations and lead to reduce fishing costs due to fuel savings.