• Title/Summary/Keyword: Frontal

Search Result 1,922, Processing Time 0.029 seconds

Name Review, and Production Method of Pyeongjeongmo, Housed by the National Palace Museum of Korea (국립고궁박물관 소장 평정모(平頂帽)의 명칭 검토와 제작방법)

  • Lee, Eun-Joo;Jin, Duk-Soon;Lee, Jeong-Min
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.2
    • /
    • pp.4-21
    • /
    • 2018
  • This paper reviewed the legitimacy of the name of those sixteen pieces of hat artifacts known in Korean as pyeongjeongmo and currently housed by the National Palace Museum. This was undertaken in order to rectify the error of calling them pyeongjeongmo. Also, the paper suggested pyeongjeongmo's production method to apply representation of the artifacts or production of Joseon officials' hats as representation of ritual costumes in the royal court. The name pyeongjeongmo originated from pyeongjeonggeon. Gyeongguk Daejeon recorded that noksas wore yugak-pyeongjeonggeon and seoris wore mugak-pyeongjeonggeon, but the pyeongjeongmo artifacts housed in the National Palace Museum have been found irrelevant to those pyeongjeonggeons put on by both noksas and seoris. Rather, they has been confirmed as corresponding to dugeon or jogeon worn by byeolgams or suboks who served at the palace of the crown prince or princess. Through the investigation of the artifacts, the researchers could find out the tailoring and sewing methods, the finished look, and the folding manner of pyeongjeonggeon. Although the structure of pyeongjeonggeon was generally consistent, the frontal look was slightly different depending on the folding manner, resulting in three distinguished types of pyeongjeonggeon. Regardless, the pyeongjeongmo was made with one piece of fabric by a flat tailoring and folding method to create a three-dimensional hat. The finished shape appeared low in the front and high in the back side structure. The head girth was 55~59 cm, and the height was 19.4~21.5 cm. To make it with one piece of fabric, the head girth part was tailored in the same direction as the strands. Based on the artifact Changdeok 23820, this paper has also suggested a finished reproduction through the processes of preparing the materials, mounting, making the center ornaments, sewing and folding. The tailoring was completed with black silk fabric which was cut in a unique shape designed in advance, and hemp fabric which was mounted to the former. The top part of the head was finished with black threads, and the center line at the back was fixed with decolored cotton threads by blanket stitches with 3.5~4 cm intervals. Bamboo strands were inserted in the inside of the front-folded part, which then was fixed by patterned stitches with white cotton thread. At the back, a small bamboo clasp was attached so that one can lock it to the headband and prevent it from falling off.

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.

Quantitative Electroencephalogram Markers for Predicting Cerebral Amyloid Pathology in Non-Demented Older Individuals With Depression: A Preliminary Study (비치매 노인 우울증 환자에서 대뇌 아밀로이드 병리 예측을 위한 정량화 뇌파 지표: 예비연구)

  • Park, Seon Young;Chae, Soohyun;Park, Jinsick;Lee, Dong Young;Park, Jee Eun
    • Sleep Medicine and Psychophysiology
    • /
    • v.28 no.2
    • /
    • pp.78-85
    • /
    • 2021
  • Objectives: When elderly patients show depressive symptoms, discrimination between depressive disorder and prodromal phase of Alzheimer's disease is important. We tested whether a quantitative electroencephalogram (qEEG) marker was associated with cerebral amyloid-β (Aβ) deposition in older adults with depression. Methods: Non-demented older individuals (≥ 55years) diagnosed with depression were included in the analyses (n = 63; 76.2% female; mean age ± standard deviation 73.7 ± 6.87 years). The participants were divided into Aβ+ (n = 32) and Aβ- (n = 31) groups based on amyloid PET assessment. EEG was recorded during the 7min eye-closed (EC) phase and 3min eye-open (EO) phase, and all EEG data were analyzed using Fourier transform spectral analysis. We tested interaction effects among Aβ positivity, condition (EC vs. EO), laterality (left, midline, or right), and polarity (frontal, central, or posterior) for EEG alpha band power. Then, the EC-to-EO alpha reactivity index (ARI) was examined as a neurophysiological marker for predicting Aβ+ in depressed older adults. Results: The mean power spectral density of the alpha band in EO phase showed a significant difference between the Aβ+ and Aβ- groups (F = 6.258, p = 0.015). A significant 3-way interaction was observed among Aβ positivity, condition, and laterality on alpha-band power after adjusting for age, sex, educational years, global cognitive function, medication use, and white matter hyperintensities on MRI (F = 3.720, p = 0.030). However, post-hoc analyses showed no significant difference in ARI according to Aβ status in any regions of interest. Conclusion: Among older adults with depression, increased power in EO phase alpha band was associated with Aβ positivity. However, EC-to-EO ARI was not confirmed as a predictor for Aβ+ in depressed older individuals. Future studies with larger samples are needed to confirm our results.

Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

Report about First Repeated Sectional Measurements of Water Property in the East Sea using Underwater Glider (수중글라이더를 활용한 동해 최초 연속 물성 단면 관측 보고)

  • GYUCHANG LIM;JONGJIN PARK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.29 no.1
    • /
    • pp.56-76
    • /
    • 2024
  • We for the first time made a successful longest continuous sectional observation in the East Sea by an underwater glider during 95 days from September 18 to December 21 2020 in the Korea along the 106 Line (129.1 °E ~ 131.5 °E at 37.9 °N) of the regular shipboard measurements by the National Institute of Fishery Science (NIFS) and obtained twelve hydrographic sections with high spatiotemporal resolution. The glider was deployed at 129.1 °E in September 18 and conducted 88-days flight from September 19 to December 15 2020, yielding twelve hydrographic sections, and then recovered at 129.2 °E in December 21 after the last 6 days virtual mooring operation. During the total traveled distance of 2550 km, the estimated deviation from the predetermined zonal path had an average RMS distance of 262 m. Based on these high-resolution long-term glider measurements, we conducted a comparative study with the bi-monthly NIFS measurements in terms of spatial and temporal resolutions, and found distinguished features. One is that spatial features of sub-mesoscale such as sub-mesoscale frontal structure and intensified thermocline were detected only in the glider measurements, mainly due to glider's high spatial resolution. The other is the detection of intramonthly variations from the weekly time series of temperature and salinity, which were extracted from glider's continuous sections. Lastly, there were deviations and bias in measurements from both platforms. We argued these deviations in terms of the time scale of variation, the spatial scale of fixed-point observation, and the calibration status of CTD devices of both platforms.

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Tc-99m ECD Brain SPECT in MELAS Syndrome and Mitochondrial Myopathy: Comparison with MR findings (MELAS 증후군과 미토콘드리아 근육병에서의 Tc-99m ECD 뇌단일 광전자방출 전산화단층촬영 소견: 자기공명영상과의 비교)

  • Park, Sang-Joon;Ryu, Young-Hoon;Jeon, Tae-Joo;Kim, Jai-Keun;Nam, Ji-Eun;Yoon, Pyeong-Ho;Yoon, Choon-Sik;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.490-496
    • /
    • 1998
  • Purpose: We evaluated brain perfusion SPECT findings of MELAS syndrome and mitochondrial myopathy in correlation with MR imaging in search of specific imaging features. Materials and Methods: Subjects were five patients (four females and one male; age range, 1 to 25 year) who presented with repeated stroke-like episodes, seizures or developmental delay or asymptomatic but had elevated lactic acid in CSF and serum. Conventional non-contrast MR imaging and Tc-99m-ethyl cysteinate dimer (ECD) brain perfusion SPECT were Performed and imaging features were analyzed. Results: MRI demonstrated increased T2 signal intensities in the affected areas of gray and white matters mainly in the parietal (4/5) and occipital lobes (4/5) and in the basal ganglia (1/5), which were not restricted to a specific vascular territory. SPECT demonstrated decreased perfusion in the corresponding regions of MRI lesions. In addition, there were perfusion defects in parietal (1 patient), temporal (2), and frontal (1) lobes and basal ganglia (1) and thalami (2). In a patient with mitochondrial myopathy who had normal MRI, decreased perfusion was noted in left parietal area and bilateral thalami. Conclusion: Tc-99m ECD SPECT imaging in patients with MELAS syndrome and mitochondrial myopathy showed hypoperfusion of parieto-occipital cortex, basal ganglia, thalamus and temporal cortex, which were not restricted to a specific vascular territory. There were no specific imaging features on SPECT. The significance of abnormal perfusion on SPECT without corresponding MR abnormalities needs to be evaluated further in larger number of patients.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

A CLINICAL STUDY ON MANDIBULAR MOVEMENT AFTER ORTHOGNATHIC SURGERY (악교정 수술환자의 술전후 하악운동 양상변화에 관한 임상적 연구)

  • Baek, Sang-Heum;Jang, Hyun-Jung;Lee, Sang-Han;Kim, Hyun-Soo;Cha, Doo-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.239-249
    • /
    • 2001
  • The purpose of this study is to evaluate the relationship of the factors which could be influenced by orthognathic surgery especillay SSRO. We measured the amounts of the maximum opening, lateral movements, maximum velocity and pattern of mandibular path during the opening and closing of mandible at the following times ; preoperative, 1 month after operation, 6 months after operation respectively using MKG. And the results were compared according to the categorized subgroups. Following results were obtained : 1. The change of the amounts of mandibular lateral movement and maximum opening velocity were statistically different between male and female (p<0.05), but the others were not. 2. According to the method of operation, there was no difference in the change of the mandibular movements between the group of SSRO and SSRO plus LeFort I osteotomy (p>0.05). 3. According to the amounts of mandibular movement, the recovery of left lateral movement of the group of $6{\sim}10mm$ was better than the other groups (p<0.05). 4. In the frontal pattern of the opening and closing of the mandible, the complex deflected type (F5), simple deflected type (F4), complex deviated type (F3), simple deviated type (F2), straight type (F1) were obtained in order at the time of preoperative, simple deflected type, simple deviated type, complex deviated type, straight type, complex deflected type in order at the time of 1 month after surgery, and the result at the time of 6 months after surgery was the same with that of the time of preoperative. In the sagittal pattern, non-coincident type (S2) was predominant at the time of preoperative, and coincident type (S1) was predominant at the time of 1 month after surgery. After 6 months, the result was also the same with that of the preoperative in sagittal pattern. 5. There was not a statistical difference in the change of the mandibular movement between group of presence of the preoperative TMJ symptoms and non-presence group (p>0.05). 6. There was not a statistical difference in the change of the mandibular movement between repositioning device applied group and non-applied group (p>0.05). 7. Sixty three percents of the patients who had preoperative TMJ symptoms were improved after surgery and preoperative TMJ symptoms were more improved after operation in the repositioning device non-applied group statistically (p<0.05).

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF