• Title/Summary/Keyword: Frequency-to-current feedback

Search Result 136, Processing Time 0.026 seconds

A sub-optimal controller design for constant-frequency series resonant converter with buck type pre-regulator (벅형 프리레귤레이터를 가진 일정주파수 직렬공진변환기를 위한 새로운 준최적제어기 설계)

  • 안희욱;고정호;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.96-100
    • /
    • 1990
  • Dynamic modelling and controller design technique for constant-frequency series resonant converter with buck type preregulator are mainly described in this paper. An equivalent circuit model is derived and a state equation is developed from this model. To improve the dynamic performance, a negative feedback of inductor current is added to the proportional and integral control of output voltage. Furthermore, an optimization technique with prescribed eigenvalue region is applied to the determination of feedback gains. With the presented design method, much better dynamic performance can be obtained.

  • PDF

A Study Compensation Method for Dynamic Characteristics in Electro-Hydraulic Servosystem Equipping Load Pressure Feedback Compensator (부하압력 피이드백 보상기를 장착한 전기-유압서보계의 동특성 개선에 관한 연구)

  • Kim, Jong-Kyum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.126-136
    • /
    • 1992
  • In this paper, a simple structured feedback compensation scheme for a electro-hydraulic servo system to keep the response characteristics unchanged regardless of the load variation is proposed. In electro-hydraulic servo system, servovalve is most important control element. But the relation between input corrent and output flowrate of the servovalve has properties as follows; firstly, in spite of constant input current, output flowrate decreases as load pressure increases, secondly, according to frequency response of typical servovalve, the characteristics of gain and phase shift is something like 2'nd order system. Load pressure feedback compensation method has been applied to eliminate the first influence, the second influence has been improved by phase lead compensation method. As a result of above compensation methods, regardless of variation load condition, spring and inertia load, the compensation scheme has been verified to be effective within the range of frequency less than 25Hz by static response and dynamic response in time domain and frequency domain through experiments.

  • PDF

A Dual-Output Integrated LLC Resonant Controller and LED Driver IC with PLL-Based Automatic Duty Control

  • Kim, HongJin;Kim, SoYoung;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.886-894
    • /
    • 2012
  • This paper presents a secondary-side, dual-mode feedback LLC resonant controller IC with dynamic PWM dimming for LED backlight units. In order to reduce the cost, master and slave outputs can be generated simultaneously with a single LLC resonant core based on dual-mode feedback topologies. Pulse Frequency Modulation (PFM) and Pulse Width Modulation (PWM) schemes are used for the master stage and slave stage, respectively. In order to guarantee the correct dual feedback operation, Phased-Locked Loop (PLL)-based automatic duty control circuit is proposed in this paper. The chip is fabricated using $0.35{\mu}m$ Bipolar-CMOS-DMOS (BCD) technology, and the die size is $2.5mm{\times}2.5mm$. The frequency of the gate driver (GDA/GDB) in the clock generator ranges from 50 to 425 kHz. The current consumption of the LLC resonant controller IC is 40 mA for a 100 kHz operation frequency using a 15 V supply. The duty ratio of the slave stage can be controlled from 40% to 60% independent of the frequency of the master stage.

Current Control Scheme of High Speed SRM Using Low Resolution Encoder

  • Khoi, Huynh Khac Minh;Ahn, Jin-Woo;Lee, Dong-Hee
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.520-526
    • /
    • 2011
  • This paper presents a balanced soft-chopping circuit and a modified PI controller for a high speed 4/2 Switched Reluctance Motor (SRM) with a 16 pulse per revolution encoder. The proposed balanced soft-chopping circuit can supply double the switching frequency in the fixed switching frequency of power devices to reduce current ripple. The modified PI controller uses maximum voltage, back-emf voltage and PI control modes to overcome the over-shoot current due to the time delay effect of current sensing. The maximum voltage mode can supply a fast excitation current with consideration of the hardware time delay. Then the back-emf voltage mode can suppress the current over-shoot with consideration of the feedback signal delay. Finally, the PI control mode can adjust the phase current to a desired value with a fast switching frequency due to the proposed balanced soft-chopping technology.

A Study on Pulse Frequency Modulated Chopper with Feedback (Feedback을 가진 P.V.M.방식 Chopper 회로에 관한 연구)

  • 박민호;전희종
    • 전기의세계
    • /
    • v.26 no.3
    • /
    • pp.63-68
    • /
    • 1977
  • In this paper, the theory of pulse frequency modulated DC/DC power converter to obtain constant output voltage for all input voltage changes is discussed. The switch controller consisting of integrator and comparator determines the ON time of power switch-Thyristor-by the error between the load voltage and a load reference voltage. Resulting voltage and current waveforms have been studied theoretically in detail and verified experimentally for a resistive and inductive load condition. State equations for voltages and currents using binary logic variables are computed by digital computer. Comparison of these withe oscillograms obtained from an experimental model shows very close agreement.

  • PDF

An Improved Active Damping Method with Capacitor Current Feedback

  • Geng, Yi-Wen;Qi, Ya-Wen;Liu, Hai-Wei;Guo, Fei;Zheng, Peng-Fei;Li, Yong-Gang;Dong, Wen-Ming
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.511-521
    • /
    • 2018
  • Proportional capacitor current feedback active damping (CCFAD) has a limited valid damping region in the discrete time domain as (0, $f_s/6$. However, the resonance frequency ($f_r$) of an LCL-type filter is usually designed to be less than half the sampling frequency ($f_s$) with the symmetry regular sampling method. Therefore, ($f_s/6$, $f_s/2$) becomes an invalid damping region. This paper proposes an improved CCFAD method to extend the valid damping region from (0, $f_s/6$ to (0, $f_s/2$), which covers all of the possible resonance frequencies in the design procedure. The full-valid damping region is obtained and the stability margin of the system is analyzed in the discrete time domain with the Nyquist criterion. Results show that the system can operate stably with the proposed CCFAD method when the resonance frequency is in the region (0, $f_s/2$). The performances at the steady and dynamic state are enhanced by the selected feedback coefficient H and controller gain $K_p$. Finally, the feasibility and effectiveness of the proposed CCFAD method are verified by simulation and experimental results.

The Analysis and Compensation of DC to DC Converter with Current Mode Controller (전류모드제어를 적용한 직류전원장치의 해석 및 보상에 관한 연구)

  • 김철진;김영태;송요창
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.230-237
    • /
    • 2003
  • Current mode control has been used for DC to DC converters for over twenty years. There are many different control schemes which use the inductor current signal in one way or another to control the DC to DC converter. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the guarantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test result. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency fc is early 1/5 of switching frequency, fs, from the experimental result with frequency response analyzer.

The small signal analysis of current-mode controlled converter (전류모드제어형 컨버터의 소신호 제어 특성)

  • Song, Yo-Chang;Kim, Young-Tae;Kim, Cherl-Jim
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.968-970
    • /
    • 2001
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.

  • PDF

A Study on the stability improvement of current-mode controlled DC-DC Converter (전류제어형 DC-DC컨버터의 안정도 향상에 관한 연구)

  • Kim, Cherl-Jin;Song, Yo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.365-367
    • /
    • 2000
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$ from the experimental result with frequency response analyzer.

  • PDF

Design of a BJT low-voltge low-frequency filter using current amplifier (전류증폭기를 이용한 BJT 저전압 저주파 필터 설계)

  • 안정철;최석우;윤창훈
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.5
    • /
    • pp.33-40
    • /
    • 1998
  • In this paper, a design of current-mode continuous-time filters for low voltage and low frequency applications using complementary bipolar current mirrors is presented. The proposed current-mode filters consist of simple bipolar current mirrors and capacitors and are quite suitable for monolithic integration. Since the design method of the proposed current-mode filters are based on the integrator type of realization, it can be used for a wide range of applications. Since the input impedance of simple bipolar current mirror is small, in this paper, negative feedback amplifier is used to realize is designed by cascade method. The cutoff frequency of the designed filter can be easily tunable by the DC controlling current from 60kHz to 120kHz. The characteristics of the designed current-mode filters are simulated and examined by SPICE using standard bipolar transistor parameters.

  • PDF