Efficient Design of 2-D FIR Fan Filters Using New Formulas for McClellan Transform Parameters

  • Song, Young-Seog;Lee, Yong-Hoon
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.1
    • /
    • pp.160-163
    • /
    • 1996
  • New formulas for McClellan transform parameters for the design of 2-D zero-phase FIR fan filters are optimally derived under the integral squared error(ISE) criterion. By imposing the constraint that F(0, 0)=\ulcorner, where F($.$) is the McClellan transform and $\omega$\ulcorner is the cutoff frequency of the 1-D prototype filter, the ISE is directly minimized without modifying it and, as a consequence, closed-form formulas for the McClellan transform parameters are obtained. It is shown that these formulas lead to a very efficient design for 2-D zero-phase FIR fan filters.

  • PDF

Numerical Modeling for Effect on Bund Overtopping Caused by a Catastrophic Failure of Chemical Storage Tanks (저장시설의 순간 전량 방출 시 방류벽의 월파 효과에 대한 수치모델링)

  • Min, Dong Seok;Phark, Chuntak;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.42-50
    • /
    • 2019
  • As the industry develops in Korea, the use of hazardous chemicals is increasing rapidly and chemical accidents are increasing accordingly. Most of the chemical accidents are caused by leaks of hazardous chemicals, but there are also accidents in which all the substances are released instantaneously due to sudden high temperature/pressure or defection of the storage tanks. This is called catastrophic failure and its frequency is very low, but consequence is very huge when it occurs. In Korea, there were 15 casualties including three deaths due to catastrophic rupture of water tank in 2013, and 64 instances of failures from 1919 to 2004 worldwide. In case of catastrophic failure, it would be able to overflow outside the bund that reduces the evaporation rate and following consequence. This incident is called overtopping. Overseas, some researchers have been studying the amount of external overflow depending on bund conditions in the event of such an accident. Based on the previous research, this study identified overtopping fraction by condition of bund in accordance with Korea Chemicals Controls Act Using CFD simulation. As a result, as the height increases and the distance to the facility decreases while meeting the minimum standard of the bund capacity, the overtopping effect has decreased. In addition, by identifying the effects of overtopping according to atmospheric conditions, types of materials and shapes of bunds, this study proposes the design of the bund considering the effect of overtopping caused by catastrophic failure with different bund conditions.

The Literature Study on Venesection therapy (자락요법(刺絡療法)의 문헌적(文獻的) 고찰(考察))

  • Min, Boo-Ki;Yoon, II-Ji;Choi, Seung-Hoon;Oh, Min-Suck
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.277-287
    • /
    • 2004
  • I have come to next conclusions in consequence of documentary study about medical books of many generations regarding venesection therapy. 1. Venesection therapy is much used for five sensory organ disease. Besides that internal disease, pain paralysis disease of muscle and joints, sugical disease, disease of woman and children, fever sunstroke CVA emergency case follow that in the order of frequency of use. 2. It is used for swollen tongue, eye pain, pharyngitis, swelling and pain in the throat, bleeding from the eye ear nose mouth or subcutaneous tissue, tonsillitis, aphthae and so on in the five sensory organ disease. Focus, sosang, jinjin yuye, taiyang, baihui are used for five sensory organ disease in the order of frequency of use. 3. It is used for malaria, headache, precordial pain, head-wind, abdominal colic, diseases characterized by acute diarrhea and vomiting, and so on in the Internal disease. Superficial venules and lymph vessesls, taiyang, quze are used for Internal disease in the order of frequency of use. 4. It is used for low back pain, hypochondriac pain, numbness, knee pain, tinea pedis, red swelling pain of hand and arm, flaccidity-syndrome, and so on in the pain paralysis disease of muscle and joints. Weizhong, superficial venules and lymph vessesls, Ashi point, zhigou are used for pain paralysis disease of muscle and joints in the order of frequency of use. 5. It is used for furuncle, tinea capitis, and so on in the sugical disease. Focus, weizhong are used for sugical disease in the order of frequency of use. 6. It is used for inflammatory disease with redness of skin, and so on in the disease of woman and children. Focus, weizhong, yanglingquan, yaoshu, sanyinjiao are used for disease of woman and children in the order of frequency of use. 7. It is used for fever, CVA, sunstroke, cadaverous coma, common cold, and so on in the fever sunstroke CVA emergency case. Sosang, weizhong, chize are used for fever sunstroke CVA emergency case in the order of frequency of use. 8. The urinary bladder channel of foot-taiyang is most used. Next there are the du channel, the stomach channel of foot-yangming, the lung channel of hand-taiyin, the gall baldder channel of foot-shaoyang, the triple-warmer channel of hand-shaoyang, the large intestine channel of hand-yangming, the spleen channel of foot-taiyin, the kidney channel of foot-shaoyin the pericardium channel of hand-jueyin the liver channel of foot-jueyin, the ren channel, the heart channel of hand-shaoyin, the small intestine channel of hand-taiyang in the order of frequency in use. 9. Superficial venules and lymph vessesls, focus, five shu points, extra-point, back point are used in the venesection therapy, those are characteristic of locating an acupuncture point.

  • PDF

A Study on an Optimal Respiration Rate for the ANS Assessment based on RSA Analysis (RSA분석과 자율신경기능을 평가하는 호흡주기 설정에 관한 연구)

  • Lee, Sang-Myung;Lee, Sung-Jun;Ahn, Jae-Mok;Kim, Jeom-Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.503-511
    • /
    • 2007
  • Heart rate variability(HRV) is the clinical consequence of various influences of the autonomic nervous system(ANS) on heart beat. HRV can estimate the potential physiologic rhythm from the interval between consecutive beats(RR interval or HRV data), but cardiovascular system governed by ANS is in relation to respiration and autonomic regulation. It is known as RSA representing respiration-related HR rhythmic oscillation. Because the mechanism linking the variability of HR to respiration is complex, it has so far been unknown well. In this paper, we tried to evaluate 5-min RR interval segments under control of respiration in order to find out a proper respiration rate that can estimate the ANS function. 10 healthy volunteers were included to evaluate 5-min HRV data under 4 different respiration-controlled environments; 0.03Hz, 0.1Hz, 0.2Hz, and 0.4Hz respiration. HRV data were analyzed both in the frequency and the time domain, with cross-correlation coefficient(cross-coeff.) for HRV and respiration signal. The results showed maximum cross-coeff. of 0.84 at 0.1 Hz and minimum that of 0.16 at 0.4Hz respiration. Cross-coeff was decreased at a faster rate from 0.1Hz respiration. All mean SDNN, RMSSD, and pNN50 of time domain measures were 108.7ms, 71.85ms, and 28.47%, respectively, and LF, HF, and TP of frequency domain measures were $12,722ms^2,\;658.8ms^2$, and $7,836.64ms^2$ at 0.1Hz respiration, respectively. In conclusion, 0.1Hz respiration was observed to be very meaningful from time domain and frequency domain analysis in relation to respiration and autonomic regulation of the heart.

Computation of the Critical Lengths of the Vertical Grounding Electrode in Multi-Layered Soil Structures (다층 대지구조에서 수직 접지전극의 임계길이 산정)

  • Kim, Ki-Bok;Joe, Jeong-Hyeon;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The grounding impedance is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode which shows the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical Length. In this paper, a new distributed parameter circuit model considering the condition of the multi-layered soil structures was proposed, and the grounding impedance and critical length of the vertical grounding electrode were analyzed by using the newly proposed simulation model and the MATLAB program. As a consequence, it was found that the effect of the soil structure on the frequency-dependent grounding impedance and critical length of the vertical grounding electrode is significant. It is desirable to consider the soil structure in optimal design of the grounding system.

A Simple Behavioral Paradigm to Measure Impulsive Behavior in an Animal Model of Attention Deficit Hyperactivity Disorder (ADHD) of the Spontaneously Hypertensive Rats

  • Kim, Pitna;Choi, In-Ha;Dela Pena, Ike Campomayor;Kim, Hee-Jin;Kwon, Kyung-Ja;Park, Jin-Hee;Han, Seol-Heui;Ryu, Jong-Hoon;Cheong, Jae-Hoon;Shin, Chan-Young
    • Biomolecules & Therapeutics
    • /
    • v.20 no.1
    • /
    • pp.125-131
    • /
    • 2012
  • Impulsiveness is an important component of many psychiatric disorders including Attention-deficit/hyperactivity disorder (ADHD). Although the neurobiological basis of ADHD is unresolved, behavioral tests in animal models have become indispensable tools for improving our understanding of this disorder. In the punishment/extinction paradigm, impulsivity is shown by subjects that persevere with responding despite punishment or unrewarded responses. Exploiting this principle, we developed a new behavioral test that would evaluate impulsivity in the most validated animal model of ADHD of the Spontaneously Hypertensive rat (SHR) as compared with the normotensive "control" strain, the Wistar Kyoto rat (WKY). In this paradigm we call the Electro-Foot Shock aversive water Drinking test (EFSDT), water-deprived rats should pass over an electrified quadrant of the EFSDT apparatus to drink water. We reasoned that impulsive animals show increased frequency to drink water even with the presentation of an aversive consequence (electro-shock). Through this assay, we showed that the SHR was more impulsive than the WKY as it demonstrated more "drinking attempts" and drinking frequency. Methylphenidate, the most widely used ADHD medication, significantly reduced drinking frequency of both SHR and WKY in the EFSDT. Thus, the present assay may be considered as another behavioral tool to measure impulsivity in animal disease models, especially in the context of ADHD.

Study on the Thermal and Dynamic Behaviors of Air Spring for vibration isolation of LCD panel inspecting machine connected with an External Chamber through a flexible tube: PART I, Theoretical Modeling (외부챔버와 유연한 튜브로 연결된 LCD 패널 검사기 방진용 공기 스프링의 열 및 동적 연성거동에 대한 연구: PART I, 이론적 모델링)

  • Seok, Jong-Won;Lee, Ju-Hong;Kim, Pil-Kee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • Due to the recent quantum leaps forward in bio-, nano-, and information-technologies (BT, NT and IT), the precisionization and miniaturization of mechanical and electrical components are in high demand. In particular, the ITrelated equipments that take a great part in our domestic industry are in the area requiring high precision technologies. As a consequence, the researches on the development vibration isolation systems that diminish external disturbance or internal vibration are highly required. Among the components comprising the vibration isolation system, air spring has become on a focal point for the researchers due to its merits. This air spring is able to support heavy loads, keep a low natural frequency despite of having a lower value of stiffness, and control the performance of vibration isolation. However, sometimes the sole use of air spring is in demand due to some economic reasons. Under this circumstance, the damping effect of sole air spring may not enough to reduce sufficient amount of vibration. In this study, the air spring mount system connecting with an external chamber is proposed to increase or control the damping effect. To investigate its damping mechanism, the thermal and dynamic behaviors of the system is examined through a theoretical modeling approach in this part of research. In this approach, thermomechanical and Helmholtz resonator type models are to be employed for the air spring/external chambers and connecting tube system, respectively. The frequency response functions (FRFs) derived from the modeling effort are evaluated with physical parametric values and the effects of connecting tube length on these FRFs are identified through computer simulations.

Study on Discomfort of Vertical Whole-body Shock Vibration Having Various Magnitudes, Frequencies and Damping (다양한 크기와 주파수 그리고 감쇠를 갖는 상하방향 전신 충격진동에 대한 불편함 연구)

  • Ahn, Se-Jin;Griffin, Michael J.;Yoo, Wan-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.50-57
    • /
    • 2007
  • Shocks are excited by impulsive forces and cause discomfort in vehicles. Current standards define means of evaluating shocks and predicting their discomfort, but the methods are based on research with a restricted range of shocks. This experimental study was designed to investigate the discomfort of seated subjects exposed to a wide range of vertical shocks. Shocks were produced from the responses of one degree-of-freedom models, with 16 natural frequencies (from 0.5 to 16 Hz) and four damping ratios (0.05 0.1, 0.2 and 0.4), to a hanning-windowed half-sine force inputs. Each type of shock was presented at five vibration dose values in the range $0.35\;ms^{-1.75}$ to $2.89\;ms^{-1.75}$. Fifteen subjects used magnitude estimation method to judge the discomfort of all shocks. The exponent in Stevens' power law, indicating the rate of growth in discomfort with shock magnitude, decreased with increasing fundamental frequency of the shocks. At all magnitudes, the equivalent comfort contours showed greatest sensitivity to shocks having fundamental frequencies in the range 4 to 12.5 Hz. At low magnitudes the variations in discomfort with the shock fundamental frequency were similar to the frequency weighting $W_b$ in BS 6841, but low frequency high magnitudes shocks produced greater discomfort than predicted by this weighting. At some frequencies, for the same unweighted vibration dose value, there were small but significant differences in discomfort caused by shocks having different damping ratios. The rate of increase in discomfort with increasing shock magnitude depends on the fundamental frequency of the shock. In consequence, the frequency-dependence of discomfort produced by vertical shocks depends on shock magnitude. For shocks of low and moderate discomfort, the current methods seem reasonable, but the response to higher magnitude shocks needs further investigation.

Synoptic Climatological Characteristics of Autumn Droughts in Korea (한국의 추계한발의 종관기후학적 특성)

  • Yang, Jin-Suk
    • Journal of the Korean association of regional geographers
    • /
    • v.6 no.2
    • /
    • pp.57-69
    • /
    • 2000
  • The purpose of this study is to identify distributional characteristics of autumn droughts in occurrence frequency and to analyze synoptic characteristics on the surface pressure fields and 500hPa levels for autumn droughts in Korea. The regional distributions of autumn droughts in occurrence frequency vary according to the monthly regional distributions of the precipitation variabilities in Korea. In september, the southwestern and the mid western parts of Korean Peninsula have high rate of drought frequency, while the eastern coast regions have low rate of it. It means that the regional distribution of the drought frequency in september indicates west-high and east-low pattern. In October, the regional distribution of the drought frequency shows low variations on regions, but in November the inland areas have low rate of drought frequency, whereas the coastal areas have high rate of it. Negative anomalies appear on the surface and 500hPa level, around Korean Peninsula during the drought period of early autumn. Positive height anomalies areas are extended from the Sea of Okhotsk to the central part of the North Pacific Ocean. It indicates that the occurrence frequencies of blocking high and ridge are high around the Sea of Okhotsk. When the pressure system, such as migratory anticyclone, stays around the Korean Peninsula, a drought occurs. In late autumn drought, the positive anomalies appear in the west and the negative anomalies in the east are generated, respectively and therefore, zonal wind is strong around Korean Peninsula. In consequence, occurrences of droughts in early autumn have a different mechanism from those of late autumn.

  • PDF

Risk Ranking Analysis for the City-Gas Pipelines in the Underground Laying Facilities (지하매설물 중 도시가스 지하배관에 대한 위험성 서열화 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.54-66
    • /
    • 2004
  • In this article, we are to suggest the hazard-assessing method for the underground pipelines, and find out the pipeline-maintenance schemes of high efficiency in cost. Three kinds of methods are applied in order to refer to the approaching methods of listing the hazards for the underground pipelines: the first is RBI(Risk Based Inspection), which firstly assess the effect of the neighboring population, the dimension, thickness of pipe, and working time. It enables us to estimate quantitatively the risk exposure. The second is the scoring system which is based on the environmental factors of the buried pipelines. Last we quantify the frequency of the releases using the present THOMAS' theory. In this work, as a result of assessing the hazard of it using SPC scheme, the hazard score related to how the gas pipelines erodes indicate the numbers from 30 to 70, which means that the assessing criteria define well the relative hazards of actual pipelines. Therefore. even if one pipeline region is relatively low score, it can have the high frequency of leakage due to its longer length. The acceptable limit of the release frequency of pipeline shows 2.50E-2 to 1.00E-l/yr, from which we must take the appropriate actions to have the consequence to be less than the acceptable region. The prediction of total frequency using regression analysis shows the limit operating time of pipeline is the range of 11 to 13 years, which is well consistent with that of the actual pipeline. Concludingly, the hazard-listing scheme suggested in this research will be very effectively applied to maintaining the underground pipelines.