• 제목/요약/키워드: Frequency phase response

검색결과 412건 처리시간 0.025초

FIR 필터를 이용한 전력계통 주파수 추정기법에 관한 연구 (A Study on the Estimation Technique of Frequency in the Power System using FIR Filter)

  • 남시복;이훈구;박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.80-85
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Frequency of a power system remains constant if sum of all the loads plus losses equals total generation in the system. However, the frequency starts to decrease if total generation is less than the sum of loads and tosses. On the other hand, the system frequency increases if total generation exceeds the sum of loads and losses. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR(finite duration impulse response) filter, a phase angle of a voltage. The rate change of the phase angle is used for estimation and speed in its process. Also, to confirm the validity of the proposed algorithm, the simulation results obtained by using EMTP(electro magnetic transients program) are shown.

  • PDF

직경이 작은 유압관로에서의 동특성 (Dynamic Respeonse of Hydraulic Pipe Lines with a Relative Small Diameter)

  • 유영태
    • 한국생산제조학회지
    • /
    • 제8권4호
    • /
    • pp.38-44
    • /
    • 1999
  • This paper primarily directed toward analyzing the frequency response in hydraulic pipe lines with a small diameter. The exact solution to the frequency response is obtained by using the complicated transfer function. The discrepancy with the exact and the approximate is small so the approximation solution is adopted to compare the experimental results with the theoretical analysis. In this experiment the input frequency was generated by the frequency generator with the ball valve and speed controller. In order to compare the theoretical were forms with the experimental ones the trace obtained from the oscilloscope is photographed, The diameter the length of lines and input pressure amplitude are varied to investigate their effects,. the experiment results show that th values of dimensionless parameter are very affected to the phase delay and guide response time in the design of pressure manifold to measure the pressure of hydraulic pipelines.

  • PDF

디지털 푸리에 변환에서 누설오차의 개선 (The Improvement of Leakage Error in Digital courier Transform)

  • 정의봉;안세진;장호엽;장진혁
    • 소음진동
    • /
    • 제11권3호
    • /
    • pp.455-460
    • /
    • 2001
  • An exact spectrum wish no leakage error could be obtained when the period of the signal coincides perfectly with the record length. However, the record length will be determined regardless of the period of signal. The Leakage error due to this problem will gibe a distorted spectrum. In the conventional research, the method was proposed to estimate the three parameters, frequency, amplitude and phase angle, from the spectrum data for anundamped sinusoidal signal. In this paper, some techniques are proposed to estimate frequency, amplitude and damping ratios from the frequency response functions for damped signals. The validation of the proposed techniques is verified by several numerical examples.

  • PDF

강한 음향장에 구속된 고압 액적의 연소 (Unsteady Vaporization of Burning Droplet at High Pressure Environments With Linear Acoustic Mode)

  • 김성엽;신현호;윤웅섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1122-1127
    • /
    • 2004
  • an isolated droplet combustion exposed to pressure perturbations in stagnant gaseous environment is numerically conducted. Governing equations are solved for flow parameters at gas and liquid phases separately and thermodynamic parameters at the interfacial boundary are matched for problem closure. For high-pressure effects, vapor-liquid interfacial thermodynamics is rigorously treated. A series of parametric calculations in terms of mean pressure level and wave frequencies are carried out employing a n-pentane droplet in stagnant gaseous air. Results show that the operating pressure and driving frequency have an important role in determining the amplitude and phase lag of a combustion response. Mass evaporation rate responding to pressure waves is amplified with increase in pressure due to substantial reduction in latent heat of vaporization. Phase difference between pressure and evaporation rate decreases due to the reduced thermal inertia at high pressure. In addition to this, augmentation of perturbation frequency also enhances amplification of vaporization rate because the time period for the pressure oscillation is much smaller than the liquid thermal inertia time. The phase of evaporation rate shifts backward due to the elevated thermal inertia at high acoustic frequency.

  • PDF

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2017
  • The Phase-Locked Loop (PLL) is widely used in grid-tie inverter applications to achieve the synchronization between the inverter and the grid. However, its performance is deteriorated when the grid voltage is not pure sinusoidal due to the harmonics and the frequency deviation. Therefore it is important to design a high performance phase-locked loop (PLL) for the single phase inverter applications to guarantee the quality of the inverter output. In this paper a simple method to improve the performance of the PLL for the single phase inverter is proposed. The proposed PLL is able to accurately estimate the fundamental frequency component of the grid voltage even in the presence of harmonic components. In additional its transient response is fast enough to track a change in grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

  • PDF

Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

  • Han, Yang;Luo, Mingyu;Chen, Changqing;Jiang, Aiting;Zhao, Xin;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1904-1917
    • /
    • 2016
  • The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of phase-locked loops (PLLs). This is of vital significance for the grid-integration and stable operation of power electronic converters to electric power systems. However, the open-loop bandwidth is drastically reduced after incorporating a MAF into the PLL structure, which makes the dynamic response sluggish. To overcome this shortcoming, some new techniques have recently been proposed to improve the transient response of MAF-based PLLs. In this paper, a comprehensive performance comparison of advanced MAF-based PLL algorithms is presented. This comparison includes HPLL, MPLC-PLL, QT1-PLL, and DMAF-PLL. Various disturbances, such as grid voltage sag, voltage flicker, harmonics distortion, phase-angle and frequency jumps, DC offsets and noise, are considered to experimentally test the dynamic performances of these PLL algorithms. Finally, an improved positive sequence extraction method for a HPLL under the frequency jumps scenario is presented to compensate for the steady-state error caused by non-frequency adaptive DSC, and a satisfactory performance has been achieved.

지진기록계 보정과 힐버트 변환 적용에 의한 센서 주파수 응답 계산 (Derivation the Correction of the Component of the Recorder and the Application of Hilbert Transformation to Calculating the Frequency Response of the Sensor)

  • 조창수
    • 지구물리와물리탐사
    • /
    • 제19권2호
    • /
    • pp.84-90
    • /
    • 2016
  • 신규 센서의 성능과 노후화된 센서의 성능 평가를 하는 것은 지진 감시 및 지진연구에 있어서 매우 중요하다고 할 수 있다. 특히 센서 주파수 응답은 지진자료의 보정을 위해서 필수적으로 사용되고 있다. 이 연구에서는 주파수 스펙트럼비를 이용한 지진 기록계의 보정 방법과 시간영역 대역통과필터(bandpass filter)와 힐버트(Hilbert) 변환을 이용한 지진계 주파수 응답을 계산하는 방법을 제시하고자 하였다. 실내 진동대 실험에서 가속도 센서(CMG-5T 1g, 2g 센서)를 설치하고 제안된 방법으로 센서 주파수 응답스펙트럼을 구하였을 때 좋은 결과를 얻을 수 있었다. 또한 2011년 도호쿠 대지진에 대하여 서울대학교 관측소(SNU)의 STS-2와 ES-T에서 얻어진 자료에 대하여 제안된 방법을 적용한 결과 STS-2 광대역 센서의 저주파수 대역에 대한 주파수 응답을 얻을 수 있었다. 대역통과필터와 힐버트 변환 방법을 이용할 경우, 주파수 스펙트럼비를 이용한 방법보다 신호대 잡음이 낮은 부분에서도 명확한 주파수 응답스펙트럼을 보여주었다.

고속 PLL을 위한 이중구조 PFD ((A Dual Type PFD for High Speed PLL))

  • 조정환;정정화
    • 대한전자공학회논문지TE
    • /
    • 제39권1호
    • /
    • pp.16-21
    • /
    • 2002
  • 본 논문에서는 TSPC(True Single Phase Clocking) CMOS 회로를 이용하여 출력특성을 향상시킨 고속 PLL을 위한 이중구조 PFD(Phase Frequency Detector)를 제안한다. 넓은 dead zone과 긴 지연시간을 갖고 있는 기존의 3-state PFD는 고속 동작에 사용되는 PLL(Phase-Locked Loop)에서 사용하는 것은 부적합하다. 이러한 3-state PFD의 단점을 해결하기 위하여 다이내믹 CMOS 논리회로로 구현된 다이내믹 PFD는 duty cycle의 변화에 따라 지터 잡음을 발생하는 문제점을 갖는다. 이러한 문제를 해결하기 위하여 TSPC 회로와 이중구조를 갖도록 설계되어 제안된 PFD는 dead zone과 duty cycle의 제한조건을 개선하였고, 지터잡음과 응답특성을 개선하였다. 즉, 이중구조를 갖는 PFD는 상승에지에서 동작하는 P-PFD(Positive edge triggered PFD)와 하강에지에서 동작하는 N-PFD(Negative edge triggered PFD)로 구성하여 이득을 증가시켜 응답특성을 개선한다. 제한된 내용의 입증을 위하여 Hspice 시뮬레이션을 수행하였다. 제안된 PFD는 dead zone이 존재하지 않으며, duty cycle의 변화에도 안정된 결과를 나타내며 응답특성이 우수함을 확인할 수 있었다.

가속도 응답을 이용한 실물 콘크리트 거더 교량의 구조건전성 모니터링 (Structural Health Monitoring of Full-Scale Concrete Girder Bridge Using Acceleration Response)

  • 홍동수;김정태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.165-174
    • /
    • 2010
  • 본 논문에서는 실물 콘크리트 거더 교량의 가속도 응답 신호를 이용하여 구조물의 상태변화를 경보한 후 그 위치 변화를 검색하는 2단계 구조건전성 모니터링 체계를 제시하였다. 먼저, 2경간 연속 콘크리트 거더 교량인 미호천교를 대상교량으로 선정하였으며, 볼링공을 이용한 강제진동 실험으로부터 동특성을 추출하였다. 다음으로, 미호천교의 2단계 구조건전성 모니터링 체계 구축을 위한 손상 발생 경보 및 손상 위치 검색 기법들을 선정하였다. 손상 경보 기법으로는 시간영역 특징을 이용하는 자기회귀모델과 주파수응답함수의 상관계수, 주파수응답비보증지수를 선정하였다. 손상 위치 검색 기법으로는 모드변형에너지기반 손상지수법을 선정하였다. 마지막으로, 덤프트럭을 이용한 정적 재하 실험을 통해 2단계 손상 모니터링 체계의 적합성을 검증하였다.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • 칸 레이안;최우진
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.231-239
    • /
    • 2018
  • The phase-locked loop (PLL) is widely used in grid-tie inverter applications to achieve a synchronization between the inverter and the grid. However, its performance deteriorates when the grid voltage is not purely sinusoidal due to the harmonics and the frequency deviation. Therefore, a high-performance PLL must be designed for single-phase inverter applications to guarantee the quality of the inverter output. This paper proposes a simple method that can improve the performance of the PLL for the single-phase inverter under a non-sinusoidal grid voltage condition. The proposed PLL can accurately estimate the fundamental frequency and theta component of the grid voltage even in the presence of harmonic components. In addition, its transient response is fast enough to track a grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.