• 제목/요약/키워드: Frequency deviation

검색결과 1,417건 처리시간 0.026초

전력계통 주파수의 고속측정을 위한 기법 (A Technique for Fast Measurement of Power System Frequency)

  • 남시복;김진수;마석범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.145-149
    • /
    • 2005
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. This paper describes the design, computational aspects and implementation of an iterative technique for measuring power system. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

CW 도플러 레이더와 FFT를 이용한 물체의 접근 이탈 정보 판단 알고리즘 (Detection Algorithm for Information on Approach or Deviation of Objects Using CW Doppler Radar and FFT)

  • 신현준;한병훈;오창헌
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.999-1001
    • /
    • 2015
  • CW 도플러 레이더는 도플러 효과를 이용하여 특정한 물체의 상대 속도를 획득할 수 있다. 하지만 두 개 이상의 물체를 탐지하기 위해서는 CW 도플러 레이더에 FFT를 사용하여 주파수 영역에서 분석해야하며, 이러한 경우 주파수 영역에서는 물체의 개수와 속도를 구할 수 있지만 물체의 접근 또는 이탈 정보를 판단하기에는 어렵다는 단점이 존재한다. 본 논문에서는 두 개 이상의 물체를 탐지하기 위해 FFT를 사용할 경우 주파수 영역에서 물체의 접근 또는 이탈 정보를 효율적으로 판단하기 위한 알고리즘을 제안한다. 제안하는 알고리즘은 주파수 영역에서 실수부와 허수부로 나눈 후 각 주파수들의 진폭을 합한 값이 주파수의 좌측에 있으면 이탈, 우측에 있으면 접근으로 판단한다.

  • PDF

전압의 주파수 편의를 이용한 동기탈조 검출 알고리즘에 관한 연구 (A Study on the Out-of-Step Detection Algorithm using Frequency Deviation of the Voltage)

  • 소광훈;허정용;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.175-181
    • /
    • 2004
  • The protection against transient instability and consequent out-of-step condition is a major concern for the utility industry. Unstable system may cause serious damage to system elements such as generators and transmission lines. Therefore, out-of-step detection is essential to operate a system safely. The detection of out-of-step is generally based upon the rate of movement of the apparent impedance. However such relay monitors only the apparent impedance which may not be sufficient to correctly detect all forms of out-of-step and cannot cope with out-of-step for a more complex type of instability such as very fast power swing. This paper presents the out-of-step detection algorithm using voltage frequency deviation. The digital filters based on discrete Fourier transforms (DFT) to calculate the frequency of a sinusoid voltage are used, and the generator angle is estimated using the deviation of the calculated frequency component of the voltage. The proposed out-of-step algorithm is based on the assessment of a transient stability using equal area criterion. The proposed out-of-step algorithm is verified and tested by using EMTP MODELS.

Effect of Center Frequency Deviation in Miniaturized CMOS Bandpass Filter

  • Kang, In-Ho;Li, Shang-Ming;Guan, Xin
    • 한국항해항만학회지
    • /
    • 제35권4호
    • /
    • pp.299-302
    • /
    • 2011
  • In this letter, the effect of quality factor on center frequency deviation in miniaturized coupled line bandpass filter (BPF) with diagonally end-shorted at their opposite sides and lumped capacitors is theoretically analyzed. The miniaturized BPF of a two-stage structure with two types of quality factors in standard CMOS process was designed and manufactured at 5.5 GHz. The die area of BPF was $1.44{\times}0.41\;mm^2$. The measured center frequency of BPF with a quality factor of 4.9 was deviated from 5.5 GHz to 4.7 GHz. The one with 14.8 was shifted to 5GHz. The theoretical and measured results validate that quality factor influences the center frequency shift of BPF.

FIR 필터를 이용한 전력계통 주파수 추정기법에 관한 연구 (A Study on the Estimation Technique of Frequency in the Power System using FIR Filter)

  • 남시복;이훈구;박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.80-85
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Frequency of a power system remains constant if sum of all the loads plus losses equals total generation in the system. However, the frequency starts to decrease if total generation is less than the sum of loads and tosses. On the other hand, the system frequency increases if total generation exceeds the sum of loads and losses. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR(finite duration impulse response) filter, a phase angle of a voltage. The rate change of the phase angle is used for estimation and speed in its process. Also, to confirm the validity of the proposed algorithm, the simulation results obtained by using EMTP(electro magnetic transients program) are shown.

  • PDF

Noise Reduction Using the Standard Deviation of the Time-Frequency Bin and Modified Gain Function for Speech Enhancement in Stationary and Nonstationary Noisy Environments

  • Lee, Soo-Jeong;Kim, Soon-Hyob
    • The Journal of the Acoustical Society of Korea
    • /
    • 제26권3E호
    • /
    • pp.87-96
    • /
    • 2007
  • In this paper we propose a new noise reduction algorithm for stationary and nonstationary noisy environments. Our algorithm classifies the speech and noise signal contributions in time-frequency bins, and is not based on a spectral algorithm or a minimum statistics approach. It relies on calculating the ratio of the standard deviation of the noisy power spectrum in time-frequency bins to its normalized time-frequency average. We show that good quality can be achieved for enhancement speech signal by choosing appropriate values for ${\delta}_t\;and\;{\delta}_f$. The proposed method greatly reduces the noise while providing enhanced speech with lower residual noise and somewhat higher mean opinion score (MOS), background intrusiveness (BAK) and signal distortion (SIG) scores than conventional methods.

연계(連繫)된 전력계통(電力系統)의 최적(最適) 부하주파수(負荷周波數) 제어(制御)

  • 한만춘;장성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1979년도 하계 전자.전기연합학술발표회논문집
    • /
    • pp.119-120
    • /
    • 1979
  • A linear state equation of the first order differential form relating the load-frequency dynamic characteristics of interconnected power systems was derived for use in computer simulation. A now solution of the algebraic matrix riccati equation for application in quadratic optimal controllor and least-square state estimator dermination was developed. The program for a dynamic state equation for two interconnected control areas was developed. The optimized load-frequency deviation was analysed and a numerical analysis was tried based on the computer simulation. It was shown that the dynamic response of th loed-frequency could be optimized with weighting factors IR and Q. The result was that the load-frequency and the tie-line deviation were visibly reduced.

  • PDF

전력시스템에서 수력발전소에 대한 최적 피이드포워드 주파수 제어 (Optimal Feedforward Frequency Control for Hydro-Power Stations in Power Systems)

  • 탁현수;류창선;안태천;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.744-747
    • /
    • 1991
  • In this paper, the design of optimal feedforward regulators with the optimal feedforward filters for improving power frequency deviations in an interconnected system, using a polynominal LQG approach, is proposed. The performances of the regulators with the optimal feedforward filters were compared with the frequency feedback regulator only in power system by simulation. The results show that the optimal feedforward regulators reduce the power frequency standard deviation by 25%-60% in the white noise load and the peak deviation in the step load by 8%-27%.

  • PDF

신경회로망을 이용한 전력계통의 부하주파수제어에 관한 연구 (Study on the Load Frequency Control of Power System Using Neural Networks)

  • 주수원;윤정태;김상효;정형환;이동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.600-602
    • /
    • 1995
  • The paper presents neural network control techniques for load frequency control of two area power system. Using learning algorithm of error back propagation after learning accept input on the optimal control $e_{i}$, $\dot{e}_{i}$, and $u_{i}$ frequency characteristic and tie-line load flow characteristic investigated dynamic. From result simulation, frequency deviation and tie-line load flow deviation have reduction remarkable.

  • PDF

부하주파수제어를 위한 퍼지-신경망 제어기에 관한 연구 (A Study on the Fuzzy-Neural Network Controller for Load Frequency Control)

  • 정형환;김상효;주석민;정문규
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 추계학술대회 학술발표 논문집
    • /
    • pp.137-144
    • /
    • 1998
  • This paper proposed a optimal scale factors technique of a fuzzy-neural network for a load frequency control of two areas power system. The optimal scale factors control technique is optimize from an initial fuzzy logic control rule, and then is learned with an error back propagation learning algorithm of the fuzzy-neural network. In application two areas the load frequency control of the power system, it hopes to have response characteristic better than optimal control technique which is the conventional control technique and to show to minimize a frequency deviation and reaching and settling time of a tie line power flow deviation

  • PDF