• 제목/요약/키워드: Frequency analyzer

Search Result 616, Processing Time 0.023 seconds

Analysis of Surface Roughness by FFT Analyzer in Turning Operation (선반작업(旋盤作業)에서의 FFT Analyzer에 의한 표면(表面)거칠기 해석(解析))

  • Kim, Gyung-Nyun;Choi, Eun-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.3
    • /
    • pp.12-19
    • /
    • 1992
  • This paper shows that the identified and unidentified components of surface roughness in NC turning lathe which can not be analyzed in time domain such as $R_{max},\;R_a$ can be isolated in frequency domain by FFT analyzer. By interfacing FFT analyzer with stylus surface roughness instrument, surface roughness on change of working condition, especially tool feed, such as 0.1, 0.15, 0.2, 0.25, 0.3(mm/rev) can be analyzed in frequency domain as follows. 1. By frequency analysis of surface roughness profile, the basic wave length of surface roughness can be obtained to isolate the identified and unidentified components of surface roughness. 2. With increase of tool feed, the unidentified components of surface roughness increase. 3. Since $R_{max}$, which can be obtained by stylus surface roughness is proportion to the output voltage of FFT analyzer, FFT analyzer also can be used to measure surface roughness in time domain such $R_a,\;R_{max}$.

  • PDF

A Study on the Design and mplementation of Frequency Converter applied to Spectrum Analyzer (스펙트럼 분석기에 적용한 주파수 변환기의 설계 및 구현에 관한 연구)

  • 이진성;송문규;김태회;박영철;차균현
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1991.10a
    • /
    • pp.103-106
    • /
    • 1991
  • Spectrum Analyzer is a useful measure instrument to display the distributed power of electrical signal as a function of frequency. It adopts the superheterodyne receiver, which mixes RF with L0 to output IF. So in this paper, two GHz-order microstrip low-pass filters, 2-section wilkinson power divider, and singly balanced diode mixer have been designed and implemented necessary to make the frequency converter applied to RF spectrum analyzer.

The Design of PC-based Power Spectral Density Analyzer of Heart Rate Variability (PC-기반의 심박변동 팍워스픽트럼밀도 분석기 설계)

  • 김낙환;이응혁;민홍기;홍승홍
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.9
    • /
    • pp.547-553
    • /
    • 2003
  • In this paper, we designed the PC-based analyzer of the power spectral density that could estimate the heart rate variability from time series data of R-R interval. The power spectral density estimated that it applied the autoregressive model to the measured electrocardiogram during a short period. Also, the characteristics of the designed analyzer are that it could process of the signal filtering, the generation and recomposition of time series and the feature extraction at the same time. Especially the analyzer reconstructed which applied the lowpass filter of the time series composed by the linear interpolation so as to enhance the signal-to-noise feature. We could estimate the power spectral density that confirmed a variety of power peak with low frequency range and high frequency rang of autonomic nerve by the heart rate variability.

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Corrosion of Quartz Crystal Marine Sensors in Sea Water (항만센서용 수정진동자의 해수에 의한 부식)

  • 최광재;장상목;김영한
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.323-328
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the corrosion process of an aluminum surface of a quartz crystal for marine sensor by sea water. A quartz crystal having 2000 $\AA$ of aluminum layer is installed in a specially designed cell and is in contact with sea water imitated electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrometer(EDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of sensor surface.

  • PDF

High-Frequency Equivalent Circuit Model for Differential Mode Noise Analysis of DC-DC Buck Converter (DC-DC 벅 컨버터의 차동모드 노이즈 분석을 위한 고주파 등가회로 모델)

  • Shin, Juhyun;Kim, Woojung;Cha, Hanju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.473-480
    • /
    • 2020
  • In this paper, we proposed a high frequency equivalent circuit considering parasitic impedance components for differential noise analysis on the input stage during DC-DC buck converter switching operation. Based on the proposed equivalent circuit model, we presented a method to measure parasitic impedance parameters included in DC bus plate, IGBT, and PCB track using the gain phase method of a network analyzer. In order to verify the validity of this model, a DC-DC prototype consisting of a buck converter, a signal analyzer, and a LISN device, and then resonance frequency was measured in the frequency range between 150 kHz and 30 MHz. The validity of the parasitic impedance measurement method and the proposed equivalent model is verified by deriving that the measured resonance frequency and the resonance frequency of the proposed high frequency equivalent model are the same.

Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 측정 장치 설계)

  • Heo, Yun-Seok
    • The Journal of Information Technology
    • /
    • v.8 no.3
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

Research on In-band Spurious Evasion Techniques of Hybrid Frequency Synthesizer

  • Kim, Seung-Woo;Yoo, Woo-Sung
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.176-185
    • /
    • 2015
  • The study aims to a design hybrid frequency synthesizer in spectrum analyzer and to propose new techniques designed for evasion of in-band spurious. The study focuses on calculating the exact location of multiple phase locked loop of hybrid frequency synthesizer and spurious of direct digital synthesizer to evade in-band spurious outside of frequency range that the user wants to see and thereby simulating technique to improve input related spurious of spectrum analyzer for algorithm. The proposed technique is designed to calculate spurious evasion algorithm in central processing system when in-band spurious arises, and to move output frequency of DDS(direct digital synthesizer) into the place where no in-band spurious exists thereby improving performance of frequency synthesizer. The study used simulation and result representation to prove the effectiveness of the proposed technique.

Analysing of the recent trends on the constitution diagnosis and treatment device patents (체질진단 및 치료기기 최신 특허동향 분석)

  • Lee, Yu-Jung;Lee, Jeon;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.91-100
    • /
    • 2007
  • In this paper, We tried to analyze the patent trend on constitution diagnosis and treatment related technologies. For this, constitution diagnosis and treatment related technologies divided into 16 sub-technology by the advisory committee. And we analyzed patents applied in Korea, Japan, U.S.A., China, and Europe. The 16 sub-technology consist of pulse analyzer, skin diagnosis, tongue analyzer, face and body detector, face analyzer, voice analyzer, intelligence ontology, meridian diagnosis, infrared thermography, electric stimulation, laser, high and low frequency, physical, magnetic, and ultrasound therapy. As a result we found that patents of constitution diagnosis and treatment in Korea has been growing steadily in both quality and quantity since 1980s. The number of patent the pulse analyzer and low frequency therapy are larger than others. But applied relevant international patents, marketability of the patent and Cites per Patent (CPP) index are shown to be very low. In conclusion, to occupy key original technologies of the Oriental medical device, we need to apply more patent of the whole related technology and international patents.

  • PDF

Corrosion of Quartz Crystal Sensors in Sea Water (항만센서용 수정진동자의 해수에 의한 부식)

  • ;;;A. Egawa;H. Muramatsu
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.183-188
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the cmsion process of an aluminum surface of a quartz crystal by sea water. A quartz crystal having 2000${\AA}$ of aluminum layer is installed in a spedally designed cell and is in contact with an electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrornetedEDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of metal surface.

  • PDF