• 제목/요약/키워드: Frequency Switching Time

검색결과 335건 처리시간 0.021초

고속 주파수 합성기를 이용한 FH-SS 송수신기의 채널 효율 개선 연구 (A Study on the Improvement of channel efficiency for FH-SS Tranceiver by applying the Frequency synthesizer with high speed switching time.)

  • 김재향;김기래
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.197-200
    • /
    • 2001
  • 최근의 확산대역 통신 방식에 사용되는 주파수 합성기는 주파수 스위칭 시간이 중요한 요소가 되고 있다. FH-SS(Frequency Hopping Spread Spectrum) 송수신기에서 고속 주파수 합성기 설계는 채널 효율을 높이기 위해 매우 중요하다. 본 논문에서는 기존 PLL방식에 직접 접근 주파수 합성 (DDS) 방식을 응용하여 1 $\mu\textrm{s}$ 이하의 스위칭 시간을 갖는 고속 주파수 합성기를 설계하고, 이를 2.4GHz 대리의FH-SS 송수신기에 적용하여 시뮬레이션 결과 20% 이상의 채널 효율 개선 효과를 얻었다.

  • PDF

A CMOS Hysteretic DC-DC Buck Converter with a Constant Switching Frequency

  • Jeong, Taejin;Yoon, Kwang S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권4호
    • /
    • pp.471-476
    • /
    • 2015
  • This paper describes a CMOS hysteretic DC-DC buck converter with a constant switching frequency for mobile applications. The inherent problems of a large output ripple voltage that the conventional hysteretic DC-DC buck converters has faced have been resolved by using the proposed DC-DC buck converter which employed a ramp generator circuit to be able to increase a switching frequency. The proposed architecture enables the settling response time of charge pump circuit within the converter to become less than 6us suitable for mobile applications. The proposed DC-DC buck converter was implemented by using 0.35 um BCDMOS process and die size was $1.37mm{\times}1.37mm$. The measurement results showed that the proposed circuit received the input of 3.7 V and generated output of 1.2 V with the output ripple voltages less than 20 mV under load currents of 100~400 mA at the fixed switching frequency of 2 MHz. The maximum efficiency of the proposed hysteretic buck converter was measured to be around 93%.

일정 스위칭 주파수를 위한 유도전동기의 직접토오크 제어 (Direct Torque Control Of Induction Motor for Constant Switching Frequency)

  • 최연옥;정병호;임병옥;정삼용;서진연;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1152-1154
    • /
    • 2002
  • In this paper, a direct torque control method of an induction motor is proposed which enables constant switching frequency. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and hysteresis band of the comparator. This paper proposes a new switching strategy which determine the effective switching time on each switching period by comparing the ascending and descending torque slopes. The simulation results are presented to verify this proposed scheme.

  • PDF

스위칭 주파수가 일정한 공진형 DC-DC코버어터 (Resinant DC-DC Converter with Constant Switching frequency)

  • 이윤종;김희준;안태영;박효식
    • 대한전기학회논문지
    • /
    • 제40권3호
    • /
    • pp.266-274
    • /
    • 1991
  • This paper proposed the resonant DC-DC converter with constant switching frequency. Its output is controlled by the auxiliary switch which is attached in conventional MRC circuits. The average output voltage is equal to the average voltage of the auxiliary switch. If the on time of the auxiliary switch is short, output voltage is decreased. Because of using the multi resonant method, the power loss from the parasitic elements can be decreased. Experimental performance of DF ZVS Forward MRC topology with switching frequency of 1MHz is presented.

높은 스위칭 주파수를 가지는 비엔나 정류기의 전류 품질 개선 (Letters Current Quality Improvement for a Vienna Rectifier with High-Switching Frequency)

  • 양송희;박진혁;이교범
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.181-184
    • /
    • 2017
  • This study analyzes the turn-on and turn-off transients of a metal-oxide-semiconductor field-effect transistor (MOSFET) with high-switching frequency systems. In these systems, the voltage distortion becomes serious at the output terminal of a Vienna rectifier by the turn-off delay of the MOSFET. The current has low-order harmonics through this voltage distortion. This paper describes the transient of the turn-off that causes the voltage distortion. The algorithm for reducing the sixth harmonic using a proportional-resonance controller is proposed to improve the current distortion without complex calculation for compensation. The reduction of the current distortion by high-switching frequency is verified by experiment with the 2.5-kW prototype Vienna rectifier.

Delay Switching PLL의 Pull-in 특성 (Pull-in Characteristics of Delay Switching Phase-Locked Loop)

  • 장병화;김재균
    • 대한전자공학회논문지
    • /
    • 제15권5호
    • /
    • pp.13-18
    • /
    • 1978
  • 본 논문에서는 PLL의 pull-in 특성을 개선하기 위하여 delay switching PL난을 제시하였다. phase detector와 low grass filter사이에 간단한 RC delay회로를 삽입하고, 90° shift 시킨 Phase detector출력에 의하여 delay time을 switching하였다. 그 결과 pull-in range는 lock range의 1/2이상으로 넓힐 수 있었으며 pull-in time도 개선되었다. 이 개선된 Pull-in특성은 근사적으로 해석되었으며 실험으로 확인되었다.

  • PDF

A Double-Hybrid Spread-Spectrum Technique for EMI Mitigation in DC-DC Switching Regulators

  • Dousoky, Gamal M.;Shoyama, Masahito;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.342-350
    • /
    • 2010
  • Randomizing the switching frequency (RSF) to reduce the electromagnetic interference (EMI) of switching power converters is a well-known technique that has been previously discussed. The randomized pulse position (RPP) technique, in which the switching frequency is kept fixed while the pulse position (the delay from the starting of the switching cycle to the turn-on instant within the cycle) is randomized, has been previously addressed in the literature for the same purpose. This paper presents a double-hybrid technique (DHB) for EMI reduction in dc-dc switching regulators. The proposed technique employed both the RSF and the RPP techniques. To effectively spread the conducted-noise frequency spectrum and at the same time attain a satisfactory output voltage quality, two parameters (switching frequency and pulse position) were randomized, and a third parameter (the duty ratio) was controlled by a digital compensator. Implementation was achieved using field programmable gate array (FPGA) technology, which is increasingly being adopted in industrial electronic applications. To evaluate the contribution of the proposed DHB technique, investigations were carried out for each basic PWM, RPP, RSF, and DHB technique. Then a comparison was made of the performances achieved. The experimentally investigated features include the effect of each technique on the common-mode, differential-mode, and total conducted-noise characteristics, and their influence on the converter’s output ripple voltage.

디지털 제어 기반의 경계점모드 브릿지리스 PFC 컨버터 (Critical Conduction Mode Bridgeless PFC Converter Based on a Digital Control)

  • 김태훈;이우철
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2000-2007
    • /
    • 2016
  • Generally, in order to implement the CRM(Critical Conduction Mode), the analog controller is used rather than a digital controller because the control is simple and uses less power. However, according to the semiconductor technology development and various user needs, digital control system based on a DSP is on the rise. Therefore, in this paper, the CRM bridgeless PFC converter based on a digital control is proposed. It is necessary to detect the inductor current when it reaches zero and peak value, for calculating the on time and off time by using the current information. However, in this paper, the on-time and off-time are calculated by using the proposed algorithm without any current information. If the switching-times are calculated through the steady-state analysis of the converter, they do not reflect transient status such as starting-up. Therefore, the calculated frequency is out of range, and the transient current is generated. In order to solve these problems, limitation method of the on-time and off-time is used, and the limitation values are varied according to the voltage reference. In addition, in steady state, depending on the switching frequency, the inductance is varied because of the resonance between the inductor and the parasitic capacitance of the switching elements. In order to solve the problem, inductance are measured depending on the switching frequency. The measured inductance are used to calculate the switching time for preventing the transient current. Simulation and experimental results are presented to verify the proposed method.

A New Frequency Controlled Half-bridge Converter with Hold-up Time Extension Circuit

  • Kim, Duk-You;Kim, Jae-Kuk;Lee, Woo-Jin;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.382-384
    • /
    • 2008
  • Hold-up time is a special requirement for the front end DC/DC converter in a server power supply. It forces the converter with the variable switching frequency to operate in a wide switching frequency range, which makes the regulation difficult and reduces the power density. In this paper a novel frequency controlled half bridge converter with the hold-up time extension circuit is proposed. During the hold-up time, the auxiliary switches are turned on, thus the resonant inductance is reduced and the voltage conversion ratio is increased. Therefore, the output capacitor of the power factor correction (PFC) circuit can be decreased, and the converter can have high power density. The proposed converter is verified by experimental results from a prototype with 700W, 400V input, and 12V output.

  • PDF

인버터 구동 고압 유도전동기의 케이블 포설시 스위칭 써지 특성 분석 (Analysis on the Switching Surge characteristic of Cable Pulling of High-Voltage Induction Motor Fed by Inverter)

  • 권영목;김재철;송승엽;신중은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.63-65
    • /
    • 2004
  • The recent advancement in the power electronic technique has increased the use of induction motor fed by inverter using high-frequency switching devices. Also the tendency is toward larger size and higher voltage. Therefore, The IGBT (Insulated-Gate Bipolar Transistor) that is high switching frequency element has been using increase. But, The switching surge voltage was occurred by high switching frequency of inverter has appeared a voltage doubling in the motor input terminal due to mismatching of cable characteristic impedance and motor characteristic impedance. Actually, The Switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. The short during rise time of switching surge and cable length is increased, the maximum transient voltage seen at the motor terminals increases. In this paper, Analyzed switching surge transient voltage of power cable pulling is used EMTP(Electromagnetic Transient Program) at the induction motor terminal and in cable.

  • PDF