EMI reduction of PWM converter By Binary Switching Frequency Modulation (2진 스위칭 주파수 변조에 의한 PWM 컨버터의 EMI 저감)

  • Jin, In-Su;Park, Seok-Ha;Yang, Kyeong-Rok;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2650-2652
    • /
    • 1999
  • To satisfy the demand for small size, light weight. high density power supply, the switching frequency of DC/DC converters has been increased. The PWM control of the conventional SMPS have a switching frequency that a level of the conducted noise spectra contribute to switching frequency band. So the electronic equipment is not only affected from that but is restricted to internal regulation like CISPR, FCC, and VDE. In this paper, we analyzed Bi-FM. Bi-FM is two fixed switching frequency with a modulation frequency. So emission spectrum of Bi-FM control signal is spreaded and spectral power level is reduced. In this paper, we analyze the spectral analysis of Bi-FM control signal and the spectral comparison between the PWM control and Bi-FM control. And we confirm that reduced the spectrum power level through simulation using Pspice and experiment.

  • PDF

Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter (듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기)

  • Lee, Sang-Wook;Ryu, Yeoi-Joung;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

The Study on FTPM and PSPM of High Frequency Induction-Heating Iron Load (고주파유도가열 철부하의 FTPM 및 PSPM 제어에 관한 연구)

  • 임영도;김두영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.192-199
    • /
    • 2000
  • This paper describes a Phase-Shift Pulse Modulation(PSPM) and Frequency Trad이ng Pulse Modulation(FTPM) s series resonant high-frequency inverter using IGBT for the power control of high-frequency induction heating u using Neuro-Fuzzy, which is practically applied for 20kHz~500kHz induction-heating and melting power supply in i indust껴aJ fields. The adaptive frequency tracking based on the PSPM(phase-shifting pulse modulation) r regulation scherne is presented in or$\tau$ler to l11lmmlZe svvitching losses. The trially-produced breadboards using N Neuro Fuzzy controller are successfully demonstrated cUld cliscussed.

  • PDF

Induction Heating PWM High Frequency Inverter using New Active Auxiliary Resonant Snubber

  • Mun, Sang-Pil;Kim, Chil-Ryong;Lee, Jong-Kurl;Kim, Hong-Sin;Jung, Sang-Hwa;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.3
    • /
    • pp.40-51
    • /
    • 2008
  • This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor(D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating.

Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터)

  • Mun, Sang-Pil;Gwon, Sun-Geol;Lee, Jong-Geol;Ju, Seok-Min;Gang, Sin-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Cost Effective Quasi-Resonant Soft Switching PWM High Frequency Inverter With Minimum Circuit Components for Consumer IH Cooker and Steamer

  • Sugimura, Hisayuki;Eid, Ahmad-M.;Nakaoka, M.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.134-139
    • /
    • 2005
  • This paper presents a cost effective quasi-resonant soft-switching PWM high frequency inverter with minimum circuit components. This inverter can achieve wider soft commutation, simpler power circuit configuration, smaller volumetric size, lower cost and wider power regulation range, higher-efficiency as compared with single ended quasi-resonant ZVS-PFM inverter and active voltage clamped quasi-resonant ZVS-PWM inverter. The operation principle of the proposed inverter is described on the basis of the simulation and experimental results, together with its operating performances in steady state. The operating performances of this unique proposed high frequency inverter based on ZVS and ZCS arms-related soft commutation principle is evaluated and discussed as compared with the active voltage-clamped ZVS-PWM inverter and a conventional single-ended ZVS-PFM inverter. The practical effectiveness of a novel type quasi-resonant soft-switching PWM high frequency inverter using IGBT is actually proved for consumer induction heated appliances as rice cooker, hot water producer, steamer and super heated steamer. The extended bidirectional circuit topology of quasi-resonant PWM high frequency inverter with minimum circuit components is demonstrated, which operate as the direct frequency changer.

  • PDF

Blockade of STAT3 in T Cells Inhibits Germinal Center Reactions against Intranasal Allergens

  • Choi, Garam;Chung, Yeonseok
    • Biomolecules & Therapeutics
    • /
    • v.24 no.3
    • /
    • pp.244-251
    • /
    • 2016
  • Understanding the developmental mechanisms of humoral immunity against intranasal antigens is essential for the development of therapeutic approaches against air-borne pathogens as well as allergen-induced pulmonary inflammation. Follicular helper T (Tfh) cells expressing CXCR5 are required for humoral immunity by providing IL-21 and ICOS costimulation to activated B cells. However, the regulation of Tfh cell responses against intranasal antigens remains unclear. Here, we found that the generation of Tfh cells and germinal center B cells in the bronchial lymph node against intranasal proteinase antigens was independent of $TGF-{\beta}$. In contrast, administration of STAT3 inhibitor STA-21 suppressed the generation of Tfh cells and germinal center B cells. Compared with wild-type OT-II T cells, STAT3-deficient OT-II T cells transferred into recipients lacking T cells not only showed significantly reduced frequency Tfh cells, but also induced diminished IgG as well as IgE specific for the intranasal antigens. Cotransfer study of wild-type OT-II and STAT3-deficient OT-II T cells revealed that the latter failed to differentiate into Tfh cells. These findings demonstrate that T cell-intrinsic STAT3 is required for the generation of Tfh cells to intranasal antigens and that targeting STAT3 might be an effective approach to ameliorate antibody-mediated pathology in the lung.

Integrated Boost-Flyback ZCS Quasi-Resonant Power Factor Preregulator (부스트-플라이백 결합형 ZCS Quasi-Resonant 역률개선 컨버터)

  • 이준영;문건우;김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.91-98
    • /
    • 1999
  • An integrated ZCS quasi-resonant converter(QRC) for the power factor correction with a single switch is presented in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of the input current. The proposed converter gives the good power factor, low line current harmonics, and tight output regulation. The input current waveform of the prototype designed using design equations shows about 15% of total harmonic distortion at rated condition. Also, the efficiency and power factor can be obtained about 86% and 0.985, respectively, at rated condition. The proposed converter is suitable for a low power level converter with a tightly regulated low output voltage and switching frequency of more than several hundreds kHz.

  • PDF

A Power Regulation and Harmonic Current Elimination Approach for Parallel Multi-Inverter Supplying IPT Systems

  • Mai, Ruikun;Li, Yong;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1245-1255
    • /
    • 2016
  • The single resonant inverter is widely employed in typical inductive power transfer (IPT) systems to generate a high-frequency current in the primary side. However, the power capacity of a single resonant inverter is limited by the constraints of power electronic devices and the relevant cost. Consequently, IPT systems fail to meet high-power application requirements, such as those in rail applications. Total harmonic distortion (THD) may also violate the standard electromagnetic interference requirements with phase shift control under light load conditions. A power regulation approach with selective harmonic elimination is proposed on the basis of a parallel multi-inverter to upgrade the power levels of IPT systems and suppress THD under light load conditions by changing the output voltage pulse width and phase shift angle among parallel multi-inverters. The validity of the proposed control approach is verified by using a 1,412.3 W prototype system, which achieves a maximum transfer efficiency of 90.602%. Output power levels can be dramatically improved with the same semiconductor capacity, and distortion can be effectively suppressed under various load conditions.

A Study on the Prediction & Transformation of Blasting Noise for Environmental Regulation Standard (발파소음의 예측기법과 환경규제 기준으로의 변환 연구)

  • 김남수;양형식
    • Explosives and Blasting
    • /
    • v.18 no.2
    • /
    • pp.14-22
    • /
    • 2000
  • The estimation of proper prediction method and the alteration of transformation method of environmental regulation standard were carried out by measuring blasting noise in construction field. The correlation of scaled distance with sound pressure level were better than with sound level, but it was proved to be difficult to control blasting noise because the correlation factor was too 1ow. three methods to transform sound pressure levee to sound level were examined. The method is the transformation by correlation equation of sound pressure level and sound level which are measured at the same time, and simplified transformation of A-weighting network corresponding to dominant frequency, and the transformation of sound pressure level by FFT. There were many errors to transform. The best effective method is the transformation using correlation equation of sound pressure level and sound level which are measured at the same time.

  • PDF