• 제목/요약/키워드: Frequency Deviation

검색결과 1,441건 처리시간 0.035초

부하 편차 방식의 전신진동운동이 하지 근력 불균형 개선에 미치는 효과 (The Effect on Improvement of Muscle Strength Imbalance According to Load Deviation Protocol of Whole Body Vibration Exercise)

  • 서신배;강승록;유창호;민진영;권대규
    • 한국정밀공학회지
    • /
    • 제30권10호
    • /
    • pp.1095-1101
    • /
    • 2013
  • The purpose of this study was to verify the effect on improvement of muscle strength unbalance according to load deviation protocol during whole body vibration exercise. Seventeen female volunteers (age $22{\pm}3$ years, height $160{\pm}4.9$ cm, weight $49{\pm}.8$ kg) participated in this experiment. The subjects performed squat exercise in WBV platform. Exercise were performed five set a day including 15 time a set, three days a week, and during 4 weeks. Vibration stimulus was 25Hz as frequency and intensity was dominant leg 1mm and non-dominant leg 4mm. The results in WBV group showed that the differences of peak torque in 16% were getting decreasing significantly after 4 weeks from 16.2% to 5.2%. This result means that WBV with load deviation protocol could provide muscle strength exercise for muscle strength balance. Our study found out that WBV of load deviation protocol could provide muscle strength exercise for improving muscle imbalance.

자세변화가 자율신경계에 미치는 영향 (The Influence of Position Change on Autonomic Nervous System Function)

  • 김인배;김은경;강종호
    • 대한물리의학회지
    • /
    • 제9권1호
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

Heart Rate Variability and Metabolic Syndrome in Hospitalized Patients with Schizophrenia

  • Lee, Kyung-Hee;Park, Jeong-Eon;Choi, Jeong-Im;Park, Chang-Gi
    • 대한간호학회지
    • /
    • 제41권6호
    • /
    • pp.788-794
    • /
    • 2011
  • Purpose: Reduced heart rate variability significantly increases cardiovascular mortality. Metabolic syndrome increases the cardiac autonomic dysfunction. Recently, increasing cardiovascular mortality has been reported in patients with schizophrenia. This study was done to compare heart rate variability between adults with and without schizophrenia and to compare the relationship of heart rate variability to metabolic syndrome in hospitalized patients with schizophrenia. Methods: This was a descriptive and correlational study in which 719 adults without schizophrenia and 308 adults with schizophrenia took part between May and June 2008. We measured the following: five-minute heart rate variability; high-frequency, low-frequency, the ratio of low-frequency to high-frequency, and the Standard Deviation of all the normal RR intervals. Data was also collected on metabolic syndrome, abdominal obesity, triglycerides, HDL cholesterol, blood pressure and fasting glucose. Results: The Standard Deviation of all the normal RR intervals values of heart rate variability indices were $1.53{\pm}0.18$. The low-frequency and high-frequency values of heart rate variability indices were significantly higher in hospitalized patients with schizophrenia ($3.89{\pm}1.36$; $3.80{\pm}1.20$) than those in the healthy participants ($2.20{\pm}0.46$; $2.10{\pm}0.46$). There were no significant differences between the schizophrenic patients with and without metabolic syndrome. Conclusion: The results of this study indicate that schizophrenia patients have significantly lower cardiac autonomic control, but they have significantly higher low-frequency and high-frequency values than those of healthy adults. Use of antipsychotic drug may affect the autonomic nervous system in schizophrenic patients. Metabolic syndrome was not associated with cardiac autonomic control in schizophrenia patients.

전력계통 주파수응답 실적 기반의 국내 AGC 주파수 바이어스 설정치 산정에 관한 연구 (A Study on the Frequency Bias Setting of the AGC based on Frequency Response in Korea)

  • 강보람;권한나;국경수
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.978-983
    • /
    • 2015
  • This paper presents Frequency Bias setting for the adequate AGC(Automatic Generator Control) operation based on the frequency response of power system in Korea. AGC frequency control recovers the frequency up to 60Hz following a primary control when the frequency suddenly drops due to a fault in power system. AGC can compensate an appropriate amount of generation by calculating ACE(Are Control Error) from the frequency deviation with the AGC frequency bias set from the actual frequency response in power systems. An appropriateness of the proposed AGC bias setting is verified through case studies employing the simulation model.

MAG용접의 Arc안정성에 미치는 Si의 영향 (Effect of Si on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제16권6호
    • /
    • pp.52-58
    • /
    • 1998
  • The effect of Si content in welding wires on th arc stability was investigate, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing Si content, average arcing time and average short circuit time were increased. Therefore, droplet transfer frequency was decreased, due to the increase of arcing time and peak current at the moment of arc-reiginition was increased, due to the increase of short circuit time. In the region of spray transfer, the fluctuations of arc current and arc voltage was the most stable in wire with Si content of about 00.60 wt.%.

  • PDF

일본인 화자의 일본어 모음에 관한 실험음성학적 분석 (An Experimental Phonetic Analysis on Japanese Vowels of Japanese Natives)

  • 이재강
    • 대한음성학회지:말소리
    • /
    • 제33_34호
    • /
    • pp.57-69
    • /
    • 1997
  • In this paper, 1 will try to examine the aspects of formants, based on the LPC analysis. In this analysis, five Japanese vowels (a, i, u, e, o) will experience two kinds of experiments: vowels in isolated forms, and vowels in carrier sentences. The analysis results of Japanese vowels of the Japanese natives show a peculiar feature that Japanese vowels form respective vowel groups. Each Japanese vowel makes a statistically significant difference. In the Fl analysis of the vowels grouped by the informant's sex, Japanese vowel (a) shows the greatest standard deviation without regard to the informant's sex. In the F2 analysis of Japanese vowels, each vowel has a statistically significant difference. The fact that the male's [u] shows great standard deviation means that there is a great difference of the frontness of the tongue among the Japanese males in articulating [u]. Isolated vowels and carried vowels show statistically little significance between Fl and F2 frequency values. In another contrastive analysis between the isolated vowel group and the carried vowel group, whether a vowel is articulated in isolation or in a sentence appears to have little effect on its formant frequency.

  • PDF

계통연계 분산전원의 새로운 단독운전 판별기법 (Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid)

  • 배병열;이두영;고종선;최남섭;한병문
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.65-72
    • /
    • 2008
  • This paper describes the development of a novel islanding detection method, which uses the signal cross-corelation scheme between the injected reactive current and the power frequency deviation. The existing method, which injects the reactive current of 2.5-5% to the rated current and detects the frequency deviation directly, brings about lowing the power quality due to the harmonic pollution. The proposed method eliminates the weak point of the existing method, because it injects the reactive current less than 1% to the rated current. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 10kVA hardware prototype. The proposed method can detect the islanding status effectively without lowing the power quality of interconnected distributed generation system.

International Time Comparison by TWSTFT and GPS at KRISS

  • Hwang, Sang-wook;Lee, Chang Bok;Lee, Jong Koo;Lee, Young Kyu;Lee, Sang Jeong;Yang, Sung-hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제5권2호
    • /
    • pp.67-74
    • /
    • 2016
  • In this paper, time comparison is performed with standardization institution in Japan using a Two-Way Satellite Time and Frequency Transfer (TWSTFT) technique as one of the methods for high precision time comparison. To analyze the performance of time comparison in the TWSTFT method, time comparison results via the Global Positioning System (GPS) code and carrier wave are analyzed. Through the time comparison performance, frequency stability is analyzed using modified Allan deviation and by this result, characteristics of time comparison of the TWSTFT that is utilized in international time comparison are presented.

온도 보상기능을 갖는 내장형RC OSCILLATOR 설계 (Design of an Embedded RC Oscillator With the Temperature Compensation Circuit)

  • 김성식;조경록
    • 대한전자공학회논문지SD
    • /
    • 제40권4호
    • /
    • pp.42-50
    • /
    • 2003
  • 본 논문에서는 시스템의 클럭을 안정적으로 공급하는 집적화 한 내장형 RC oscillator의 구현에 관한 논문이다. 기존의 RC oscillator는 온도에 따라 주파수변화가 약 15%정도 변화가 있는데 이는 온도에 따른 저항값의 변화와 schmit trigger의 기준전압이 온도에 따라 변화하기 때문이다. 본 연구에서는 온도에 따른 주파수 변화를 최소화하는 방법으로 CMOS bandgap과 온도에 따른 전류의 변화를 이용하였다. CMOS bandgap으로 기준 전압을 얻고 온도에 따라 증가하는 전류원과 온도에 따라 감소 하는 전류원을 서로 합하면 온도에 따라 일정한 전류를 얻어 주파수의 변화를 약 3%이내로 유지하는 회로를 제안한다.

800 MHz 주파수도약 시스템을 위한 분수분주 방식 주파수 합성기의 설계 및 제작 (N fractional frequency synthesizer for 800 MHz frequency hopping)

  • 박종문;이승대;방성일;진연강
    • 한국통신학회논문지
    • /
    • 제21권2호
    • /
    • pp.526-533
    • /
    • 1996
  • In this paper, the 800 MHz band N fractional frquency synthesizer having 677 channel with 30 kHz channel bandwidth is designed on the based on the theory which is dervied in terms of the relation between reference freqiency and the number of channels, loop bandwidth and acquistion time. The experimental resuls show 10 Hz deviation from the bandwidth and acquisition time. The experimental results show 10 Hz deviation from the bandwidth, the spurious suppression of aroud -45 dBc and the acqusition time of 1.44 ms. The results satisfy the given specification, but don't achieve thebesired spurious -60 dBc suppression. It is found that 500 hop per second will be possible over the range from 800 to 820 MHz.

  • PDF