• Title/Summary/Keyword: Frequency Band

Search Result 5,002, Processing Time 0.027 seconds

Design of Ferrite Composite Microwave Absorber (복합 Ferrite 전파흡수체의 설계방안)

  • 신재영;오재희
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.1
    • /
    • pp.11-16
    • /
    • 1994
  • The impedance matching solution map is not a sufficient method for designing the broad-band absorber because of its difficulty to get numerical data about practical band-width. Therefore, we develope a new method to design the broad-band absorber. The complex permeability limits, which is necessary for designing the broad-band absorber in C-X band (4 GHz~12.4 GHz) were investigated and application was also examined. The complex permeability limits represent the frequency dependence of the complex permeability at a practical frequency band. These complex permeability limits can be used effectively to design broad-band single-layered absorber because they offer numerical data about the band-width in the case of various dielectric loss tangent, practical frequency bands and permitted reflection losses of an absorber.

  • PDF

Design of a Wide-Band CMOS VCO With Reduced Variations of VCO Gain and Frequency Steps for DTV Tuner Applications (VCO 이득 변화와 주파수 간격 변화를 줄인 DTV용 광대역 CMOS VCO 설계)

  • Ko, S.O.;Sim, S.M.;Sho, H.T.;Kim, C.K.;Yu, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.217-218
    • /
    • 2008
  • Since the digital TV signal band is very wide ($54{\sim}806MHz$), the VCO used in the frequency synthesizer must also have a wide frequency tuning range. Multiple LC VCOs have been used to cover such wide frequency band. However, the chip area increases due to the increased number of integrated inductors. A general method for achieving both reduced VCO gain(Kvco) and wide frequency band is to use the switched-capacitor bank LC VCO. In this paper, a scheme is proposed to cover the full band using only one VCO. The RF VCO block designed using a 0.18um CMOS process consists of a wideband LC VCO with reduced variation of VCO gain and frequency steps. Buffers, divide-by-2 circuits and control logics the simulation results show that the designed circuit has a phase noise at 100kHz better than -106dBc/Hz throughout the signal band and consumes $9.5{\sim}13mA$ from a 1.8V supply.

  • PDF

Prediction of Defibrillation Success of Ventricular Fibrillation ECG Signals using Time-Frequency Analysis (시-주파수 분석을 이용한 심실세동시 심전도 분석을 통한 제세동 예측에 관한 연구)

  • Sung, Hong-Mo;Shin, Jae-Woo;Lee, Hyun-Sook;Hwang, Sung-Ho;Yoon, Young-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.4
    • /
    • pp.181-188
    • /
    • 2006
  • The purpose of this study is to predict the defibrillation success of a ventricular Fibrillation ECG signal using time-frequency analysis. During CPR, coronary perfusion pressure and electrocardiogram were measured. Parameters extracted from time-frequency domain were served as predictor of resuscitation success. Time frequency distribution(TFD) of ECG signals was estimated from the smoothed pseudo Wigner-Ville distribution(SPWVD). Median frequency, peak frequency, 1/f slope, frequency band ratios$(2{\sim}4Hz,\;4{\sim}6Hz,\;6{\sim}8Hz,\;8{\sim}10Hz,\;10{\sim}12Hz,\;12{\sim}15Hz)$ were extracted from each TFD as function of time. Paired t-test was used to determine the differences in ROSC and non-ROSC groups. In the statistical results, we selected four significant parameters - median frequency, 1/f slope, $2{\sim}4Hz$ band ratio, $8{\sim}10Hz$ band ratio. We made an attempt to predict defibrillation success by combining features extracted from time frequency distribution. Independent t-test was used to determine the differences ROSC and non-ROSC groups. Consequently, we selected four significant parameters-median frequency, 1/f slope, $2{\sim}4Hz$ band ratio, $8{\sim}10Hz$ band ratio. The relationship between coronary perfusion pressure and ECG parameters was analyzed with linear regression analysis. R-square value was 55%. 1/f slope and $8{\sim}10Hz$ band ratio had the significant relationship with coronary perfusion pressure.

Joint Estimation Schemes of Carrier and Sampling Frequency Offsets for MB-OFDM UWB Systems (MB-OFDM UWB 시스템을 위한 반송파 및 샘플링 주파수 오프셋 결합 추정 기법)

  • Cho, Chang-Hoon;Yang, Suck-Chel;Shin, Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.965-975
    • /
    • 2005
  • In this paper, we propose and evaluate joint carrier and sampling frequency offset estimation schemes based on the channel estimation sequences in PLCP (Physical Layer Convergence Procedure) preamble for the proper and effcient synchronization of the MB-OFDM WB (Multi-Band Orthogonal Frequency Division Multiplexing Ultra Wide Band) systems which have recently drawn explosive attention for future W-PAN (Wireless Personal Area Network) applications. In the joint estimation schemes, we first estimate the sampling frequency offset, and then estimate the carrier frequency offset using the estimated sampling frequency offset. Moreover, to improve the reliability of the estimated offset values, each process uses a combination scheme based on weighting factors. Simulation results using IEEE 802.15 Task Group 3a UWB channel models reveal that the estimation scheme using the simple weighting factors based on easily-measurable received signal power of each sub-channel shows favorably comparable performance to the ideal scheme using the weighting factors based on the perfectly-estimated frequency response of the channel.

Proper frequency band as EMG fatigue indices of biceps femoris muscles during treadmill walking (드레트밀 보행시 대퇴이두근의 EMG 근피로지수로서 적당한 주파수 대역)

  • Jongchil Won;Kiyoung Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.3
    • /
    • pp.141-145
    • /
    • 2024
  • Because of muscle fatigue, motor unit recruitment and firing rates decrease and EMG power spectrum shifts toward lower frequencies as spectral compression which represented by a falling shift in the median frequency. However, changes of this frequency shows relatively less than those of the magnitudes of the low frequency band. This paper aims to examine the moderate ranges of the frequency bands in the existed ones as spectral fatigue indices of biceps femoris muscle. Twelve subjects participate in this experiment, and EMG signals are measured from these muscles during treadmill walking on the speed of 4.5 km/h. ANOVA analysis is used to compare changes of the low and high frequency band with reference to those of median frequency. Experimental results demonstrate that the low frequency band 25-82 Hz and the high frequency band 142-300 Hz could be appropriate for spectral fatigue indices of biceps femoris muscles.

Design of Broad Band Electromagnetic Wave Absorbers with Cross-Shaped Ferrite. (십자형 광대역 페라이트 전자파흡수체의 설계)

  • 김동일;전상엽;정세모
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1996.09a
    • /
    • pp.125-134
    • /
    • 1996
  • A design method of double layered electromagnetic wave absorbers with cross-shaped ferrite prominence in the second layer which has broad band frequency characteristics was proposed. The broad band electromagnetic wave absorber can be designed under some approximations by the theoretical model using the equivalent material constants method for the second layer. Based on the developed model broad band electromagnetic wave absorbers with excellent reflectivity frequency characteristics in the frequency range of 30MHz to 3,990MHz were designed.

  • PDF

Double Square Patch Antenna with Inductive Bridges for WLAN Dual-Band (인덕티브 브릿지를 가진 WLAN 이중 대역 이중 사각 패치 안테나)

  • Yang, Chan-Woo;Jung, Chang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2615-2618
    • /
    • 2009
  • Double rectangular patch with 4-bridges is investigated for solution of IEEE 802.11b/g (2.4 GHz) and 802.11a (5.5 GHz). Rectangular patch for 5.5 GHz frequency band is printed on the PCB substrate and connected to another rectangular patch for 2.4 GHz frequency band with 4-bridges to obtain dual band operation in an antenna element. 4-bridges can modify the desired frequency band from its original frequency band by changing its width. Gain of 2.4 GHz patch is 5 dBi and 5.5 GHz patch is 3.7 dBi at ${\theta}=0^{\circ}$.

Design of Ka/Ku Band Frequency Selective Surface with Triple Square Loop Slot Array (삼중 사각 루프 슬롯 배열 형태를 갖는 Ka/Ku 대역 주파수 선택 반사기 설계)

  • 고지환;조영기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.10
    • /
    • pp.1060-1070
    • /
    • 2003
  • The frequency selective surface for use in Ka/Ku band parabolic antenna of domestic satellite communications is proposed. The frequency selective surface structure consists of the infinite periodic arrays of the triple square loop slot element with narrow width on the honeycomb structure of multi-layered dielectric. The frequency selective surface is fabricated and measured. The good agreement is obtained between theory and experiment. It is demonstrated that the frequency selective surface passes 14/12 GHz band wave while reflecting 30/20 GHz band wave as required.

A Study on Low Frequency Band Selection as a Fatigue Parameter in Surface EMG during Isotonic Exercise of Biceps Brachii Muscle (상완이두근의 등장성 운동시 근피로인자로서 표면근전도의 저주파수대역 선정에 관한 연구)

  • Lee, Sang-Sik;Lee, Ki-Young
    • Journal of Biosystems Engineering
    • /
    • v.36 no.4
    • /
    • pp.285-289
    • /
    • 2011
  • Muscle fatigue is characterized as a progressive increase in discomfort arising from the active muscle at moderate load levels are maintained. The median frequency is the most commonly used as a parameter to describe muscle fatigue. However, the estimate of the median frequency is difficult to indicate muscle fatigue because of its high standard deviation and instability. This paper investigates the power changes of the appropriate low frequency band as a fatigue parameter in EMG during isotonic exercise. To select the appropriate band, linear regression lines are employed to calculate the slopes and the coefficient of determination. Three females and seven males volunteered to participate in surface EMG recordings placed on the biceps brachii and each recording experiment continued until their exhaustion. The results of experiment shows that the power changes of the selected low frequency band (15~45 Hz) have linear slopes and high determinant coefficients. Therefore, this fatiguing parameter using the power changes of the low frequency band is valid to measure the state of muscular fatigue.

AJ Performance of the FH-CSS(Frequency Hopped - Chirp Spread Spectrum) Communication Systems (NED를 사용하는 FH-CSS(Frequency Hopped - Chirp Spread Spectrum)의 항 재밍 성능 분석)

  • Kim, Sung-Ho;Kim, Young-Jae;Hwang, Seok-Gu;Jo, Byoung-Gak;Shin, Kwan-Ho;Kim, Nam
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • In the defence wireless communications, conventional Anti-Jamming techniques(Frequency Hopping/Spread Spectrum or Direct Sequence/Spread Spectrum) are used to overcome a intentional interfering signals which are single/multitone or partial band jammer etc. DS/SS techniques is very strong on tone jamming signal but not to be on a partial band jammer. So FH/SS AJ performances are expected method of an substitution of DS/SS, however FH/SS could not have good performance on some BMTJ(Band Multi-tone Jammer). So this paper proposes FH-CSS (Frequency Hopped - Chirp Spread Spectrum) to get more robustness against jammers(BMTJ, PBNJ) and analyze the AJ performances.