• Title/Summary/Keyword: Freon gas

Search Result 24, Processing Time 0.023 seconds

Performance Analysis of 2-Stage Compression and 1-Stage Expansion Refrigeration System using Alternative Natural Refrigerants (암모니아 대체 자연냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측)

  • Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.42-47
    • /
    • 2012
  • In this paper, alternative natural refrigerant R290(Propane), R600(Butane), R717(Ammonia), R1270(Propylene) for freon refrigerant R22 were used working fluids for 2-stage compression and 1-stage expansion refrigeration system. The operating parameters considered in this study included evaporation temperature, condensation temperature, subcooling degree, superheating degree, mass flow rate ratio of inter-cooler. The main results were summarized as follows : The COP of 2-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling degree and mass flow rate ration of inter-cooler, but decreases with the increasing evaporating temperature, condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of 2-stage compression and 1-stage expansion refrigeration system using natural refrigerants have an effect on COP of this system. The COP of natural refrigerants was higher than the COP of freon R22 in this study, so points to be considered are the security, the attached facilities for natural refrigerants than COP.

Study on the Cavitation Damage of Cupronickel(70/30) Tube for Gas Absorption Refrigeration Machine

  • Lim, Uh-Joh;Jeong, Ki-Cheol;Yun, Byoung-Du
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.332-337
    • /
    • 2004
  • The use of gas absorption refrigeration machine has considerably increased because of the shortage of the electric power in the summer and the regulation of freon refrigerant. Gas absorption refrigeration machine consists of a condenser, a heat exchanger. supplying pipes, a radiator etc, This system is likely to be corroded by acid. dissolved oxygen and gases, Cavitation erosion-corrosion by flow velocity of cooling water may happen in absorption refrigeration machine. In these cases. erosion and corrosion occur simultaneously. Then, it makes a serious damage with synergy effect. Therefore, this paper was studied on the cavitation damage of cupronickel(70/30) tube for gas absorption refrigeration machine, In the $30^{\circ}C$ tap water, linear polarization test and anodic polarization test were carried out for copper(C1220T-OL) and cupronickel(70/30) tube. Also, cavitation erosion-corrosion behavior of cupronickel (70/30) tube was considered, The main results are as following: (1) In the linear test, the corrosion current density of cupronickel(70/30) is higher than that of copper. (2) The erosion-corrosion rate of cupronickel(70/30) displayed later tendency than that of copper by vibratory cavitation in cooling water. (3) In cooling water, the progress mechanism of erosion-corrosion rate of copper and cupronickel(70/30) follows a pattern of incubation, acceleration, attenuation and a steady state period.

R&D OF FREEZING AND REFRIGERATION SYSTEM USING CHP. (가역 화학 열 펌프(CHP)를 이용한 냉장.냉동 시스템 개발 연구)

  • 이종호;김석종
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.132-135
    • /
    • 1996
  • This study is to develop an ammonia based chemical heat pump(STELF) for a freezing and refrigeration system coupled to gas, fuel and/or waste from industrial processes as heat sources. Recently it has been continually taking a growing interest in chemical heat pumps without electric power and having higher COP's than those of existing compression type refrigeration systems using freon. By introducing STELF technology, efficient heat recovery utilizing enormous amount of waste heat in energy consuming large scale industries or building for their own refrigeration purposes is possible. Moreover, air-conditioning systems coupled to city gas for small scale industries or building can be realized. Therefore, STELF technology can contribute much for overall energy savings and efficient energy management.

  • PDF

A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids (LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.

A Study on the Technical Strategy in the IMO Air Pollution Prevention (IMO의 대기오염규제에 따른 기술적 대응전략에 관한 연구)

  • 김종헌
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.S1
    • /
    • pp.77-85
    • /
    • 1996
  • As conservation of global environment has becoming a major outstanding issue of the world, the International Maritime Organization(IMO) has been legislation a convention for prevention of air pollution from ships. By the new convention, use of air pollutants such SOx, NOx, Freon and Halin Gas shall be restricted. In this regards, analysing these requirements of the convention is required as the cinvention will also be applied in restriction of descharging exhaust gases from ships by estsblishing a requirement of Sox and NOx discharged. The purpose of this study is as follows; 1) Introdcuing of the backgrounds of legislating the convention for prevention of air pollution from ships and major contents of the convention and a countermeasuures in the convention by Korea 2) Reviewing by analyzing the influence in domestic industries concernd by restriction of SOx, NOx in exhaust gases and sulpher content of fuel oil 3) Preparing a countermeasure in the convention properly.

  • PDF

A Study on the Technical Strategy on the IMO Air Pollution Prevention (IMO의 대기오염규제에 따른 기술적 대응전략에 관한 연구)

  • Kim, Jong Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.69-69
    • /
    • 1996
  • As conservation of global environment has becoming a major outstanding issue of the world, the International Maritime Organization(IMO) has been legislation a convention for prevention of air pollution from ships. By the new convention, use of air pollutants such as SOx, NOx, Freon and Halon Gas shall be restricted. In this regards, analysing these requirements of the convention is required as the convention will also be applied on restriction of discharging exhaust gases from ships by establishing a requirement of SOx and NOx discharged. The purposed of this study is as follows ; 1) Introducing of the backgrounds of legislating the convention for prevention of air pollution from ships and major contents of the convention and a countermeasures on the convention by Korea. 2) Reviewing by analyzing the influence on domestic industies concerned by restriction of SOx, NOx in exhaust gases and sulphur content of fuel oil. 3) Preparing a countermeasure on the convention properly.

A Study on the Technical Strategy on the IMO Air Pollution Prevention (IMO의 대기오염규제에 따른 기술적 대응전략에 관한 연구)

  • 김종헌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 1996
  • As conservation of global environment has becoming a major outstanding issue of the world, the International Maritime Organization(IMO) has been legislation a convention for prevention of air pollution from ships. By the new convention, use of air pollutants such as SO/sub x/, NO/sub x/, Freon and Halon Gas shall be restricted. In this regards, analysing these requirements of the convention is required as the convention will also be applied on restriction of discharging exhaust gases from ships by establishing a requirement of SO/sub x/ and NO/sub x/ discharged. The purposed of this study is as follows ; 1) Introducing of the backgrounds of legislating the convention for prevention of air pollution from ships and major contents of the convention and a countermeasures on the convention by Korea. 2) Reviewing by analyzing the influence on domestic industies concerned by restriction of SO/sub x/, NO/sub x/ in exhaust gases and sulphur content of fuel oil. 3) Preparing a countermeasure on the convention properly.

  • PDF

Study on the characteristics of nucleate boiling heat transfer with changing of surface roughness (표면거칠기의 변화에 따른 핵비등열전달의 특성에 관한 연구)

  • 김춘식;정대인;배종욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.64-78
    • /
    • 1983
  • In nucleate boiling, bubbles are created by the expansion of entrapped gas or vapor at small cavities in the surface of heat transfer. Namely, surface roughness is the important factor of heat transfer. This paper deals with the characteristics of boiling curve according to surface roughness. Freon-113 is used as the experimental fluid. The results are as follows; 1. In the case of the same as "q=C$\Delta$T$^{n}$ ", the lower numberical index "n", the larger heat transfer coefficient and the lower wall superheat "$\Delta$T" is obtained for the rougher surface. 2. In the working of every kind of heat transfer sruface with boiling, improvement of capabilities of heat transfer can be devised by adding suitable roughness on the heat transfer surface. 3. When the metal nets of moderate mesh number are established, the capabilities of heat transfer can be improved in evaporation of liquid in vessels. But in the case that the sucession of bubbles in checked by using the nets which are too tight, the generation of bubbles union decreases critical heat flux. decreases critical heat flux.

  • PDF

A Study on the District Community Cooling System using LNG Cold Energy (LNG 냉열이용 지역집단 냉방시스템에 대한 연구)

  • Kim, Chung-Kyun;Kim, Seung-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.27-30
    • /
    • 2010
  • This paper presents the system design process of district community cooling system using LNG cold energy. The newly developed LNG cooling system includes several heat exchangers, LNG storage tank, thermal mass storage tank, several cold energy storage tanks, gas air-conditioners, compressors, constant pressure regulators, cold energy and hot energy supply pipes. In addition, the gas air-conditioner system is installed to supply not sufficient cold energy due to low level of city gas consumptions during a summer period. This system design is very effective and safe to supply cold energy mass of fresh air by exchanging two thermal masses of an air and 200kcal/kg cold energy of LNG. The district community cooling system with LNG cold energy does not produce CO2 and freon gases in the air.

Development of the cooling effect skincare product using LPG as propellant (액화 석유가스를 이용한 냉각 화장품 개발)

  • Kim Hwayong;Park Chanik;Bae Won
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.1-6
    • /
    • 2003
  • Freon gas has been replaced with LPG in the cosmetic industry because of its bad effects on environment. In this paper, skincare product with a cooling effect was developed using LPG as propellant. A cooling effect is obtained by the ice which is formed through spraying. Ice formation is affected by the composition of LPG and most of all, the high content of propane gas in the LPG results in the irregular surface of ice formed because of its high vapor pressure. Also the ratio of LPG to skincare solution affects the formation of ice.

  • PDF