• Title/Summary/Keyword: Freezing efficiency

Search Result 125, Processing Time 0.03 seconds

Cryogenic Machining of Open-Cell Silicone Foam (액화질소를 이용한 오픈 셀 실리콘 폼의 냉동 절삭조건 최적화)

  • Hwang, Jihong;Cho, Kwang-Hee;Park, Min-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.32-37
    • /
    • 2014
  • Open-cell silicon foam is difficult to cut using conventional machining processes because of its low stiffness. That is, open-cell silicon foam is easily pressed down when the tool is engaged, which makes it difficult to remove the material in the form of chip. This study proposes an advanced method of machining open-cell silicon foam by freezing the material using liquid nitrogen. Furthermore, the machining conditions are optimized to maximize the efficiency of material removal and minimize the usage of liquid nitrogen by conducting experiments under various machining conditions. The results show that open-cell silicone foam products with free surface can be successfully machined by employing the proposed method.

A Study on Optimization Development of Peltier Air-conditioning System (펠티어 냉난방시스템 최적화 기술에 관한 연구)

  • Park, Sanghoon;Jeong, Soojin;Park, Youngwoo;Park, Ukyung;Song, Beomjung
    • Journal of Institute of Convergence Technology
    • /
    • v.3 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • This study is concerned with air-conditioning system in use of thermoelectric device. It is introduced that the well designed structures for better cooling & heating performance with high efficiency. And also it is performed that the system performance test of four types trial products for the use of hybrid commercial vehicle. System performance is affected by many component parts, especially heat sink design & power control method. It is applied that dual extrusive fin tube with buffer zone for the effective radiating of circulating liquid in tube. And also it is applied that power supply method with constant-current system. It is attained that system cooling capacity is 1.2kW, COP is 0.95.

  • PDF

Encapsulation of Plasmid DNA in Pegylated Liposome

  • Jang, Jung-Ok;Gwak, Hye-Sun;Lee, Hwa-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.337-341
    • /
    • 2005
  • The purpose of the study was to prepare the pegylated liposome carrying plasmid DNA with optimal encapsulation efficiency. Plasmid DNA (pCEP4 clone 790, 10.6 kb) was entrapped in the pegylated liposome composed of neutral lipid, POPC (l-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine), cationic lipid, DDAB (dimethyl dioctadecyl ammonium bromide) and anionic lipids, DSPE-PEG 2000 (distearoyl phosphatidyl ethanolamine polyethylene glycol 2000) and DSPE-PEG 2000-maleimide by freezing/thawing method. Free plasmid DNA was separated from the encapsulated one by Sepharose CL-4B column chromatography. The DNA amount encapsulated into the pegylated liposome was increased as cationic lipid concentration, initial amount of plasmid DNA and total lipid amount were increased.

The Optimum Temperature of Brine Heating System for LNG Storage Tank (LNG 저장탱크용 Brine Heating System의 최적온도 설정)

  • Oh, B.T.;Hong, S.H.;Yang, Y.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.361-366
    • /
    • 2001
  • The purpose of installation of the brine heating system for LNG storage tank is the prevention of ground freezing. If the ground of LNG tank areas is frozen, it is caused by safety problems. The design of brine heating system for LNG storage tank which is constructing in our country is not well considered about domestic weather conditions and economical efficiency. Therefore, this paper reports on the study of the optimized temperature of inside pipes and cooling process through the transient analysis by using the existing brine heating system.

  • PDF

Flow pattern analysis and a study on formation of slurry ice in the reversing flow (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

An Study on Efficiency and Application of Thermal Siphon in the Permafrost (영구동토 지대에서 Thermal Siphon의 효율성 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

An Experimental Study on the Performance of a Freeze-Protected Direct Solar Water Heating System (비동파 직접식 온수 급탕 시스템의 열성능에 관한 연구)

  • Chun, W.G.;Kim, H.T.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.33-38
    • /
    • 1998
  • This paper reports the experimental results concerning the thermal performance of a freeze-protected direct solar water heating system. The direct system tested has been manufactured to prevent any breakage during harsh wintry conditions by specially designed riser and downcomer headers capable of relieving extra pressure due to freezing of water. The direct system tested has shown 10% improvement in its efficiency over that of a indirect type system using antifreeze as the heat transfer medium. It is felt that any direct system of its kind could galvanize the whole solar industry if further improvements are made to ensure its durability.

  • PDF

Purification and Acetylation of Protein X Subunit of Pyruvate Dehydrogenase Complex (PDC) from Bovine Kidney

  • Ryu, Ryu;Song, Byoung-J.;Hong, Sung-Youl;Huh, Jae-Wook
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.502-506
    • /
    • 1996
  • Protein X is one of the subunits of pyruvate dehydrogenase complex. The biological role of this protein has not been fully elucidated, mainly because of the difficulty in its dissociation from the tightly bound dihydrolipoamide acetyltransferase-protein X subcomplex. We have found that the detachment of protein X from acetyltransferase subunit can be easily accomplished by the cycles of freezing and thawing proces. Several lines of evidence including sodium dodecyl sulfate-polyacrylamide gel electrophoresis, N-terminal amino acid sequence analysis and acetylation with $[2^{14}C]$ pyruvate confirmed that the purified protein is protein X. The purified intact form of protein X was acetylated by $[2^{14}C]$ pyruvate in the presence of py-ruvate dehydrogenase subunit.The acetylation efficiency of this protein was lower than that of acetyltransferase and was not affected by the presence of acetyltransferase.

  • PDF

Basic Experiment on Frost of Plate Fin Coil Evaporator (플레이트 휜 코일형 증발기의 착상에 관한 기초 실험)

  • 백승문;김창영;한인근;김재돌;윤정인
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF

A study on the application Heat Pump to Rolling Stock Air conditioner (히트펌프식 냉난방장치의 철도차량 적용에 관한 연구)

  • Kweon, Tae-Kyun;Song, Young-Jeong;Jeong, Gwang-Moo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1689-1696
    • /
    • 2008
  • Heat pumps transfer heat by circulating a substance called a refrigerant through a cycle of evaporation and condensation. But Heat pumps system by only using heat-source is not efficient. Because the mean temperature of North Korean winter season is low, economy of air heat-source heat pump descend. This paper is practiced the simulation on evaluation criteria for Heat pump heating and cooling systems to Rolling Stock. Efficiency of the heat pump in order improving from certainly the development of the technique will be able to prevent a freezing actual condition must proceed. As a result, Below $-10^{\circ}C$ used heating and cooling systems of heat pump format even in cold winter season and is serviceable confirmed with heat source supply circle of the Rolling Stock.

  • PDF