• Title/Summary/Keyword: Freezing Heat-Transfer

Search Result 89, Processing Time 0.031 seconds

Classification of cold regions and analysis of the freeze-thaw repetition cycle based on heat transfer quantity by freezing test (실내동결시험을 통한 열류량 분석에 따른 동결-융해 조건 분석 및 한랭지역의 분류)

  • An, Jai-Wook;Seo, Jeong-Eun;Jung, Min-Hyung;Seong, Joo-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.957-972
    • /
    • 2018
  • Tunnels constructed in cold regions can cause serious defects such as cracks and leaks due to external temperature changes in the portals and vents. In order to prevent the freezing damage of the tunnel, appropriate measures should be applied to the section where the freeze damage is concerned. However, the specific criteria and contents for judging whether or not the anti-freeze measures are applied are not presented. In this study, the laboratory freezing tests on the temperature changes of the concrete specimens under freezing conditions were carried out. And the freeze-thaw repetition cycle (F), which can judge the possibility of freezing damage, were presented based on the heat transfer quantity (W) by experimental results of case studies. Also, we propose a classification of cold regions considering the climatic characteristics of Korea for using it to efficient design and maintenance.

Mathematical Relationship between Ice Dendrite Size and Freezing Conditions in Tuna

  • Choi, Mi-Jung;Hong, Geun-Pyo;In, Dae-Sik;Min, Sang-Gi
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.330-335
    • /
    • 2009
  • The principal objective of this study was to investigate changes in ice dendrite size during the freezing of tuna, in order to formulate a mathematical model of ice dendrite size. The tuna was frozen via a uni-directional heat transfer. Thermogram analysis allowed us to determine the position of the freezing front versus time, which is referred to as the freezing front rate. The morphology of the ice dendrites was assessed via scanning electron microscopy after freeze-drying, and the retained pore size was measured as ice dendrites. We noted that the mean size of ice dendrites increased with the distance to the cooling plate; however, it decreased with reductions in the cooling rate and the cooling temperature. In addition, shorter durations of the freeze-drying process decreased the freezing front rate, resulting in a larger size of the ice dendrite pores that operate as water vapor sublimation channels. According to our results, we could derive a linear regression as an empirical mathematical model equation between the ice dendrite size and the inverse of the freezing front rate.

A Study on Freezing Assessment of the Water in the Z-Trap of Sewage Bay (PVC 오수받이 내부 Z형 트랩의 동결성 평가에 관한 연구)

  • Lee, Changwoo;Oh, Seungju
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.98-104
    • /
    • 2016
  • This study clarifies the simulation on freezing of remaining water in the Z-trap set up in the PVC sewage bay to control malodor. It made use of commercial FEM LAB program(ver. 3.2) well known as a solution of the problems arising in the flow of various fluid, heat transfer and mass transfer. Simulation results under the temperature $-20^{\circ}C$ outwards show that the water in the Z-trap set up in the sewage bay to control malodor freeze in the 60cm under the ground level after 14 days in the wet ground, and after 17 days in the regular ground. On the other hand, if the soil is dry even after the 42 days does not go down below freezing. Therefore, the water in the Z-trap was confirmed that it does not freeze.

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution (마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구)

  • Chang Young- Soo;Yun Won -Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

Evaluation of Floor Heating Performance and Design Criteria for Operating an Outdoor Swimming Pool During Winter : A Case Study (동절기 옥외 수영장 시설의 운영을 위한 바닥난방 성능평가 및 설계기준에 관한 사례연구)

  • Cho, Jinkyun;Woo, Kyunghun;Kim, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.289-296
    • /
    • 2017
  • This study aimed to analyze the deck floor heating system of an outdoor swimming pool in terms of the thermal capacity/output and the surface temperature distribution based on the outdoor temperature, to design for anti-freezing during winter. Through the transient heat transfer simulation with PHYSIBEL and theoretical equations, the surface temperature distribution of the floor heating system at two outdoor conditions in Jeju, were calculated and evaluated. The results indicate that the specific thermal output required for maintaining $4^{\circ}C$ surface temperature at the design outdoor temperature of $0.1^{\circ}C$, was about $90W/m^2$. This performance analysis can be applied for future design criteria, including optimizations of system capacity and size.

An investigation on the system characteristics of a refrigerator with alternative refrigerants (대체냉매를 이용한 가정용 냉장고의 시스템 특성에 관한 연구)

  • 신진규;문춘근;윤정인
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.753-762
    • /
    • 1998
  • A domestic refrigerator is composed of many components such as a compressor, evaporator, capillary tube, and the cabinet which plays a great role on the cycle performance, even if it is not the basic component part in the cycle. Recently, the restriction policy on the energy-saving and environmentally friendly refrigerator is reinforced in our nation as well as developed countries. Therefore, in this paper, cycle simulations and experiments were carried out ito understand the characteristics of the cycle performance using CFC 12, HFC 134a, and HC 600a and to know how changes in UA(overall heat transfer coefficients$\times$ heat transfer area) of evaporator, the position displacement of compressor, and the rpm of fan in the freezing room which has influence on the cycle performance. The result shows that the quantitative values of simulation and experiment are not coincident, but their trend is similar. When HFC 134a and HC 600a were used without the change of design in refrigerator used CFC 12, the performance of system in HC 600a is 30% lower, and the case of HFC 134a is 10% lower than that of CFC 12 on freezing temperature.

  • PDF

Frost Prevention of Fin-Tube Heat Exchanger by Spreading Antifreezing Solution (부동액 도포에 의한 핀-튜브 열교환기 착상방지)

  • Oh, Sang-Youp;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.477-485
    • /
    • 2006
  • A study on frost prevention of fin-tube heat exchanger is experimently performed by spreading antifreezing solution on heat exchanger surface. It is desirable that the antifreezing solution spreads completely on the surface forming thin liquid film to prevent frost nucleation and crystal growth and to reduce the thermal resistance across the liquid film. A small amount of antifreezing solution falls in drops on heat exchanger surface using two types of supplying devices, and a porous layer coating technique is adopted to enhance the wettedness of antifreezing solution on the surface. It is observed that the antifreezing solution liquid film prevents fin-tube heat exchanger from frosting, and heat transfer performance does not degrade through the frosting tests. The concentration of supplied antifreezing solution can be determined by heat transfer analysis of the first row of heat exchanger to avoid antifreezing solution freezing due to dilution by moisture absorption.

An Study on Efficiency and Application of Thermal Siphon in the Permafrost (영구동토 지대에서 Thermal Siphon의 효율성 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

A study on the application Heat Pump to Rolling Stock Air conditioner (히트펌프식 냉난방장치의 철도차량 적용에 관한 연구)

  • Kweon, Tae-Kyun;Song, Young-Jeong;Jeong, Gwang-Moo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1689-1696
    • /
    • 2008
  • Heat pumps transfer heat by circulating a substance called a refrigerant through a cycle of evaporation and condensation. But Heat pumps system by only using heat-source is not efficient. Because the mean temperature of North Korean winter season is low, economy of air heat-source heat pump descend. This paper is practiced the simulation on evaluation criteria for Heat pump heating and cooling systems to Rolling Stock. Efficiency of the heat pump in order improving from certainly the development of the technique will be able to prevent a freezing actual condition must proceed. As a result, Below $-10^{\circ}C$ used heating and cooling systems of heat pump format even in cold winter season and is serviceable confirmed with heat source supply circle of the Rolling Stock.

  • PDF

Freezing Characteristics in a Horizontal Rectangular Channel with the Two-Dimensional Protuberances (2차원 직사각형 덕트 내부에 돌기부를 갖는 흐름의 동결특성에 관한 연구)

  • Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.721-727
    • /
    • 2003
  • Freezing of turbulent water flow between two horizontal cooled parallel plates with the separated region has been investigated experimentally. The flow separation was induced by vertical plates (two-dimensional plates) situated at the inlet of the rectangular channel. The degree of flow separation was varied by employing vertical thin plates with various heights. Three kinds of the vertical plates with 8.0, 9.8 and 12.5 mm in height were utilized. The Reynolds number and cooling temperature ratio were ranged from $3.45\times10^3 to 1.73\times10^4$ and 7.0 to 20.0 respectively, The measurements show that the flow separation influenced remarkably on the local ice formation characteristics. The location of the first ice layer and the average heat transfer at the ice surface were found be correlated as a function of the Reynolds number, the cooling temperature ratio, and the orifice height ratio.