• Title/Summary/Keyword: Free decay

Search Result 167, Processing Time 0.03 seconds

Rechlorination for residual chlorine concentration equalization in distribution system (급배수시스템에서 잔류염소 농도 균등화를 위한 재염소 처리)

  • Kim, Jinkeun;Han, Ji-An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.91-101
    • /
    • 2014
  • Three water treatment plants(WTPs) in Jeju island whose source water have different characteristics from those of the mainland of Korea were investigated. Coefficients of bulk water decay($k_b$) of free chlorine at $5^{\circ}C$ for ES, GJ, NW WTPs were $-0.003hr^{-1}$, $-0.002hr^{-1}$ and $-0.001hr^{-1}$ respectively based on bottle tests. To simulate the free chlorine variations in the distribution system using EPANET, ES WTP was chosen. Free chlorine concentrations of several sites were less than the drinking water quality standards(i.e., 0.1 mg/L); E5(0.03 mg/L), E6(0.02 mg/L), W21(0.02 mg/L) and W25(0.03 mg/L). To maintain more than 0.1 mg/L of free chlorine in the distribution system, at least 1.9 mg/L of chlorine was needed at the WTP, which suggested rechlorination was needed to supply palatable tap water to customers. Two sites, one that diverged into E5 and E6 in the east-line and another located before E21 in the west-line were selected for the appropriate rechlorination locations. The recommended rechlorination dosages were 0.42 mg/L for the east and 0.27 mg/L for the west. The simulated results indicated that the free chlorine could be reduced to 0.4 mg/L at the WTP with rechlorination, and taps with excessive free chlorine could be more stabilized(i.e., 0.1~0.4 mg/L).

Development of Radiation Free Soft X-Ray Ionizer with Ion Control (완전차폐 및 이온조절형 연X선식 정전기제거장치의 개발)

  • Jeong, Phil Hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.22-27
    • /
    • 2016
  • The Electrostatic Charge Prevention Technology is a core factor that highly influences the yield of Ultra High Resolution Flat Panel Display and high-integrated semiconductor manufacturing processes. The corona or x-ray ionizations are commonly used in order to eliminate static charges during manufacturing processes. To develop such a revolutionary x-ray ionizer that is free of x-ray radiation and has function to control the volume of ion formation simultaneously is a goal of this research and it absolutely overcomes the current risks of x-ray ionization. Under the International Commission on Radiological Protection, it must have a leakage radiation level that should be lower than a recommended level that is $1{\mu}Sv/hour$. In this research, the new generation of x-ray ionizer can easily control both the volume of ion formation and the leakage radiation level at the same time. In the research, the test constraints were set and the descriptions are as below; First, In order not to leak x-ray radiation while testing, the shielding box was fully installed around the test equipment area. Second, Implement the metallic Ring Electrode along a tube window and applied zero to ${\pm}8kV$ with respect to manage the positive and negative ions formation. Lastly, the ion duty ratio was able to be controlled in different test set-ups along with a free x-ray leakage through the metallic Ring Electrode. In the result of experiment, the maximum x-ray radiation leakage was $0.2{\mu}Sv/h$. These outcome is lower than the ICRP 103 recommended value, which is $1{\mu}Sv/h$. When applying voltage to the metallic ring electrode, the positive decay time was 2.18s at the distance of 300 mm and its slope was 0.272. In addition, the negative decay time was 2.1s at the distance of 300 mm and its slope was 0.262. At the distance of 200 mm, the positive decay time was 2.29s and its slope was 0.286. The negative decay time was 2.35s and its slope was 0.293. At the distance of 100 mm, the positive decay time was 2.71s and its slope was 0.338. The negative decay time was 3.07s and its slope was 0.383. According to these research, the observation was shown that these new concept of ionizer is able to minimize the leakage radiation level and to control the positive and negative ion duty ratio while ionization.

Transition of Turbulent Kinetic Energy Through a Serial Unit of Straight-Duct, Contraction and Free-Jet (상류유동전개부, 수축부 및 자유분사류로 이어지는 유동장에서의 난류에너지 천이에 대한 연구)

  • 한용운;남경덕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2368-2375
    • /
    • 1992
  • The transition of turbulent kinetic energy(TKE) balance along the centerline of the flow unit, which is composed of straight-duct, contraction and free-jet, has been investigated by the hot-wire anemometry. It is found that the mean turbulent kinetic energy is balanced by the dissipation in the internal flow region ; by the production and the dissipation, through contraction ; and by the dissipation, in initial region(X〈8D) of free-jet. But in the developing region (8D〈X〈20D) it is balanced by all of the three(ie, diffusion, production and dissipation). Finally, in the downstream of free-jet, the mean TKE is balanced again by dissipation like as the beginning. The decay-laws along the centerline are checked in the region of free jet as well as in the straightduct. After the developing region of free-jet also exist the decay-laws, the exponent of the axial turbulence being bigger than of the radial.

Numerical simulations of two-dimensional floating breakwaters in regular waves using fixed cartesian grid

  • Jeong, Kwang-Leol;Lee, Young-Gill
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.206-218
    • /
    • 2014
  • The wave attenuation by floating breakwaters in high amplitude waves, which can lead to wave overtopping and breaking, is examined by numerical simulations. The governing equations, the Navier-Stokes equations and the continuity equation, are calculated in a fixed Cartesian grid system. The body boundaries are defined by the line segment connecting the points where the grid line and body surface meet. No-slip and divergence free conditions are satisfied at the body boundary cell. The nonlinear waves near the moving body is defined using the modified marker-density method. To verify the present numerical method, vortex induced vibration on an elastically mounted cylinder and free roll decay are numerically simulated and the results are compared with those reported in the literature. Using the present numerical method, the wave attenuations by three kinds of floating breakwaters are simulated numerically in a regular wave to compare the performance.

Preliminary tests of a damaged ship for CFD validation

  • Lee, Sung-Kyun;You, Ji-Myoung;Lee, Hyun-Ho;Lim, Tae-Gu;Rhee, Shin-Hyung;Rhee, Key-Pyo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.2
    • /
    • pp.172-181
    • /
    • 2012
  • One of the most critical issues in naval architecture these days is the operational safety. Among many factors to be considered for higher safety level requirements, the hull stability in intact and damaged conditions is the first to ensure for both commercial and military vessels. Unlike the intact stability cases, the assessment of the damaged ship stability is very complicated physical phenomena. Therefore it is widely acknowledged that computational fluid dynamics (CFD) methods are one of most feasible approaches. In order to develop better CFD methods for damaged ship stability assessment, it is essential to perform well-designed model tests and to build a database for CFD validation. In the present study, free roll decay tests in calm water with both intact and damaged ships were performed and six degree-of-freedom (6DOF) motion responses of intact ship in regular waves were measured. Through the free roll decay tests, the effects of the flooding water on the roll decay motion of a ship were investigated. Through the model tests in regular waves, the database that provides 6DOF motion responses of intact ship was established.

Relationship between Bacterial Regrowth and Free chlorine Residuals in Water Distribution System

  • Lee, Yoon-Jin;Yoon, Tae-Ho;Jun, Byong-Ho;Oh, Kyoung-Doo;Nam, Sang-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.136-139
    • /
    • 2003
  • This study is to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution system which belongs to both K and Y water treatment plant of S city of Korea. The data analyzing in distribution systems (DS) shows that the free chlorine residuals decrease from 0.10 to 0.56 mgmg/L for K, and 0.51 to 0.78 mg/L for Y. The decay of free chlorine is clearly higher in both March and August than those of in January. The HPC in DS are ranged from 0 to 40 CFU/mL for K, 0 to 270 CFU/mL for Y, on R2A medium. In particular, its level is relatively high at consumers ground storage tanks, taps and point-of-end area of Y. The predominant genera is studied in distribution systems are Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increase in the end-point area. Most of them are either encapsulated cells or cocci of gram-positve. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from water treatment plants, the greater diversity and higher level of heterotrophic bacteria due to the significant decay of free chlorine residuals.

  • PDF

Centerline Turbulent Characteristics of an Axisymmetric Flow with the Swirl (소용돌이 성분이 있는 축대칭유동의 중심난류 특성)

  • 남경덕;한용운
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2724-2737
    • /
    • 1994
  • The swirl effect on an axisymmetric turbulence has been investigated along its centerline by the hot wire anemometry. Flow facility to generate and conrol the swirl has been built by using the rotating honeycomb and grid. For the case of internal flows, as the strength of the swirl increases the flow tends to be locally isotropic by modifying the radial and the rotational components mainly. In comparison with those of the plain free jet, the decay of the centerline turbulences seems to be delayed substantially even with a slight swirl component.

DECAY OF TURBULENCE IN FLUIDS WITH POLYTROPIC EQUATIONS OF STATE

  • Lim, Jeonghoon;Cho, Jungyeon
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.2
    • /
    • pp.49-57
    • /
    • 2020
  • We present numerical simulations of decaying hydrodynamic turbulence initially driven by solenoidal (divergence-free) and compressive (curl-free) drivings. Most previous numerical studies for decaying turbulence assume an isothermal equation of state (EOS). Here we use a polytropic EOS, P ∝ ργ, with polytropic exponent γ ranging from 0.7 to 5/3. We mainly aim at determining the effects of γ and driving schemes on the decay law of turbulence energy, E ∝ t. We additionally study probability density function (PDF) of gas density and skewness of the distribution in polytropic turbulence driven by compressive driving. Our findings are as follows. First of all, we find that even if γ does not strongly change the decay law, the driving schemes weakly change the relation; in our all simulations, turbulence decays with α ≈ 1, but compressive driving yields smaller α than solenoidal driving at the same sonic Mach number. Second, we calculate compressive and solenoidal velocity components separately and compare their decay rates in turbulence initially driven by compressive driving. We find that the former decays much faster so that it ends up having a smaller fraction than the latter. Third, the density PDF of compressively driven turbulence with γ > 1 deviates from log-normal distribution: it has a power-law tail at low density as in the case of solenoidally driven turbulence. However, as it decays, the density PDF becomes approximately log-normal. We discuss why decay rates of compressive and solenoidal velocity components are different in compressively driven turbulence and astrophysical implication of our findings.

Characteristics of Residual Free Chlorine Decay in Reclaimed Water (하수재이용수의 유리잔류염소 수체감소 특성 연구)

  • Kang, Sungwon;Lee, Jaiyoung;Lee, Hyundong;Park, Jaehyun;Kwak, Pilljae;Oh, Hyunje
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.4
    • /
    • pp.276-282
    • /
    • 2013
  • The reclaimed water has been highlighted as a representative alternative to solve the lacking water resources. This study examined the reduction of residual free chlorine by temperature (5, 15, $25^{\circ}C$) and initial injection concentration (1, 2, 4, 6 mg/L) in the reclaimed water and carried out propose on the calculating method of the optimal chlorine dosage. As the reclaimed water showed a very fast reaction with chlorine at the intial time comparing to that of drinking water, the existing general first-order decay model ($C_t=C_o(e^{-k_bt})$) was not suitable for use. Accordingly, the reduction of residual free chlorine could be estimated in a more accurate way as a result of applying the exponential first-order decay model ($C_t=a+b(e^{-k_bt})$). ($r^2$=0.872~0.988). As a result of calculating the bulk decay constant, it showed the highest result at 653 $day^{-1}$ under the condition of 1 mg/L, $25^{\circ}C$ for the initial injection whereas it showed the lowest result at 3.42 $day^{-1}$ under the condition of 6 mg/L, $5^{\circ}C$ for the initial injection. The bulk decay constant tends to increase as temperature increases, whereas the bulk decay constant tends to decrease as the initial injection concentration increases. More accurate calculation for optimal chlorine dosage could be done by using the experimental results for 30~5,040 min, after the entire response time is classified into 0~30 min and 30~5,040 min to calculate the optimal chlorine dosage. In addition, as a result of calculating the optimal chlorine dosage by temperature, the relationships of initial chlorine demand (y) by temperature (x) could be obtained such as y=1.409+0.450x to maintain 0.2 mg/L of residual free chlorine at the time after 4 hours from the chlorine injection.

Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET (EPANET을 이용한 상수도 관망의 잔류염소 거동 예측)

  • 유희종;김주원;정효준;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.