• Title/Summary/Keyword: Free chlorine

Search Result 135, Processing Time 0.023 seconds

Green Purification System using Natural Hydrogen Generating Mineral Filter (천연 수소 발생 광물 필터를 이용한 녹조 정화 시스템)

  • Yu-ji Kwon;Dae-gyeom Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.475-485
    • /
    • 2024
  • In many regions of Korea, including the Four Major Rivers, the seriousness of the problem of algal blooms due to eutrophication of water quality is being raised.In this study, in order to solve these social problems, we manufactured a filter using natural mineral fusion (red illite, zeolite, germanium ceramic, selenium ceramic, carbon ceramic) and independently developed a tank system for green algae experiments to observe and determine the stages of change in water quality. In order to study ways to improve water quality through quantitative analysis, 1 ton of severely polluted green algae water from the Nak dong River region was stored in a water tank and exposed to ultraviolet rays in the same environment as the Nak dong River. Then, the same environment as the Nak dong River was created. The results were derived from a 5-week water quality test. The results of this experiment confirmed that green-colored cyano bacteria were significantly reduced just by the turbidity results. The results were obtained through a request to the Korea Testing & Research Institute located in Changwon-si, Gyeong sang nam-do. CI-(chlorine ion) and NH3-N(ammonia nitrogen) had the effect of saving every week. The device used in this study was made of natural minerals free of heavy metals that are harmless to the human body and nature through long-term consideration and exploration to kill and prevent various strains living in water. Green purification system using natural hydrogen generating mineral filter were effective a non-chemical and physical methods. The results of this study are one way to contribute to the serious problems caused by green algae in many countries, and will contribute to the water quality environment by preventing the waste of environmental resources, improving the health of the people, and increasing the ability to purify environmental water quality at home and abroad.

Comparison of Biofilm Formed on Stainless Steel and Copper Pipe Through the Each Process of Water Treatment Plant (정수처리 공정 단계별 스테인리스관과 동관에 형성된 생물막 비교)

  • Kim, Geun-Su;Min, Byung-Dae;Park, Su-Jeong;Oh, Jung-Hwan;Cho, Ik-Hwan;Jang, Seok-Jea;Kim, Ji-Hae;Park, Sang-Min;Park, Ju-Hyun;Chung, Hyen-Mi;Ahn, Tae-Young;Jheong, Weonhwa
    • Korean Journal of Microbiology
    • /
    • v.49 no.4
    • /
    • pp.313-320
    • /
    • 2013
  • Biofilm formed on stainless and copper in water treatment plant was investigated for sixteen weeks. Biofilm reactor was specially designed for this study. It was similar to that of a real distribution pipe. Raw water, coagulated, settled, filtered and treated water were used in this study. The average number of heterotrophic bacteria counts was $1.6{\times}10^4CFU/ml$, $5.8{\times}10^3CFU/ml$, $1.8{\times}10^3CFU/ml$, $1.3{\times}10^2CFU/ml$, 1 CFU/ml, respectively. Density of biofilm bacteria formed on stainless and copper pipes in raw, coagulated and settled water increased above $2.9{\times}10^3CFU/cm^2$ within second weeks while more biofilm bacteria counts were found on the stainless pipe than on the copper pipe. In case of filtered water (free residue chlorine 0.44 mg/L), there was no significant difference in the number of biofilm bacteria on both pipes and biofilm bacteria below $18CFU/cm^2$ were detected on both pipe materials after fifth weeks. Biofilm bacteria were not detected on both pipe materials in treated water (free residue chlorine 0.88 mg/L). According to the results of DGGE analysis, Sphingomonadacae was a dominant species of biofilm bacteria formed on the stainless pipe while the copper pipe had Bradyrhizobiaceae and Sphingomonadaceae as dominant bands. In case of filtered water, a few bands (similar to Propionibacterium sp., Sphingomonas sp., Escherichia sp., and etc.) that have 16S rRNA sequences were detected in biofilm bacteria formed on both pipes after fifth weeks. Stainless pipe had higher species richness and diversity than the copper pipe.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.

New Bleaching Method for KP with Permanganate(III) -Evaluation of Role of Oxalic Acid as a Acid Catalyst and a Reductant on the Permanganate Oxidation with Phenolic Model Compounds- (과망간산칼륨을 이용한 KP의 새로운 표백법(제3보) -모델화합물 실험에서 Oxalic acid 첨가의 평가-)

  • Yasuo Kojima
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.1
    • /
    • pp.73-79
    • /
    • 2001
  • Stricter environmental demands have increased the need to replace conventional C/D bleaching sequence by chlorine-free sequence. Permanganate is well known as a powerful oxidant and have been used industrially in variable fields. However, it has considered to be difficult to use permanganate as a bleaching reagent because of its strong oxidative effect decreasing the viscosity of pulps extremely. We have tried to use permanganate as a bleaching reagent for KP under the mild condition and it was clear that pernanganate oxidized lignin remained in pulps selectively and increased pulp brightness decreasing K number of pulps with small degradation of cellulose. We have employed the neutral condition in the permanganate bleaching process in this study. In this case, permanganate was converted to manganese dioxide after bleaching reaction. The manganese dioxide is remained in the treated pulp fibers because of its insolublity in water. So it was required to reduction the manganese oxide to manganese ion by using reductants with acid. In this paper, we proposed to use oxalic acid as a reducing reagent converting manganese oxide to manganese ion after bleaching reaction. Oxalic acid plays the role as a reductant and a acid, so post-treatment after bleaching became to be easy by using oxalic acid. On the study using lignin model compounds, it was clear that permaganate react with phenols firstly, after that oxalic acid reduce the manganese oxide to manganese ion in the mixture of permanganate, phenols and oxalic acid. Several lignin model compounds ($\textit{p}$-hydroxybenzaldehyde, vanillin, syringaldehyde, veratraldehyde) are selected to elucidate the effect of substituents on reaction rate and its mechanism with permanganate including oxalic acid in this study. Except for veratraldehyde, the rate of oxidative degradation of phenolic compounds by permanganate with oxalic acid are higher than neutral condition. Especially, the degradation rate of $\textit{p}$-hydroxybenzaldehyde are strongly dependent on pH of reaction mixture. On the other hand, the degradation rate of veratraldehyde are decreased with decreasing pH and main degradation product is veratric acid. This result indicate that pH of bleaching liquor should be kept over 2 to degrade of non-phenolic lignin in the pulps effectively in permanganate bleaching.

  • PDF

Application of Electrochemical Technology for Reusing Biologically Treated Water (생물학적 처리수 재이용을 위한 전기화학 기술의 적용)

  • Kang, Gu-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.453-458
    • /
    • 2008
  • Laboratory experiments were conducted to investigate disinfection as well as removal of color and residual organics from reclaimed municipal wastewater by electrochemical processes with Nb/Pt anode installed. RNO was rapidly bleached by OH$\cdot$ and the second order rate constants of RNO removal were $\frac{0.223l}{mg{\cdot}min}$, $\frac{1.679l}{mg{\cdot}min}$ and $\frac{2.322l}{mg{\cdot}min}$ with for 5 A, 10 A, and 15 A, respectively, with r$^2$ of > 96%. In batch electrochemical processes, after 15 min at currency of 15 A and initial pH of 5, 7,5 and 9, COD$_{Mn}$ was below 4 mg/L, color unit below 5 degree and general bacteria was not detected, the concentration of which are suitable for drinking water regulation. In the continuous electrochemical process, with HRT of 3.7$\sim$49.2 min, free chlorine were 0.2$\sim$0.7 mg/L, general bacteria was not detected, color unit below 5 degree and THMs was 0.017 mg/L. Therefore, electrochemical process with Nb/Pt anode was employed satisfactory to meet for reusing biologically treated water as well as disinfection.

Effects of Mung Bean (Phaseolus aureus L.) on Blood Glucose and Lipid Composition Improvement in Streptozotocin-induced Diabetic Rats (녹두(Phaseolus aureus L.) 급여가 당뇨 유발 흰쥐의 혈당 및 지질성분 개선에 미치는 영향)

  • Bark, Si-Woo;Kim, Han-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.162-172
    • /
    • 2020
  • The purpose of this study was to investigate the improvement effect of 5% mung bean (phaseolus aureus L.) on the blood glucose and lipid metabolism function of streptozotocin (STZ, 45 mg/kg body weight)-induced diabetic rats. Seven-week-old male rats were divided into four groups (n=6), and fed experimental diets containing mung bean meal [basal diet+5% mung bean (BM), basal diet+STZ+5% mung bean (SM)], and control (BD), BS groups (basal diet+STZ). The results of this study, mung bean diet groups (BM, SM) in lipid composition evidenced the significantly reduction of serum total cholesterol, low density lipoprotein-cholesterol (LDL-cholesterol), atherosclerotic index (AI), cardiac risk factor (CRF), triglyceride (TG), phospholipid (PL), free cholesterol, cholesteryl ester, uric acid, blood glucose, non esterified fatty acid (NEFA), and elevation of high density lipoprotein-cholesterol (HDL-cholesterol). The serum albumin/globulin ratio (A/G ratio) was increased in mung bean supplementation diet than STZ-induced diabetic rats (p<0.05). Concentrations of sodium (Na) and chlorine (Cl) in sera were lower in the mung bean diet than diabetic group. Total calcium (T-Ca), phosphorus (Pi) and potassium (K) concentrations in sera were higher in the BM, SM and BD groups than BS group. In vivo experiments with Sprague-Dawley rats showed that ingestion of mung bean (phaseolus aureus L.) were effective in blood glucose and lipid composition.

Evaluation of Filter-Adsorber(F/A) Process for Removal of Disinfection By-products(DBPs) (소독부산물 제어를 위한 실공정 F/A 운영에 관한 고찰)

  • Kim, Seong-Su;Lee, Kyung-Hyuk;Lim, Jae-Lim;Chae, Seon-Ha;Kang, Byeong-Soo;Moon, Pil-Joong;Ahn, Hyo-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1035-1042
    • /
    • 2005
  • Granular Activated Carbon(GAC) is widely used in drinking water treatment. At S and B Water Treatment Plant, GAC is used in place of granular media in conventional rapid filters(GAC Filter-Adsorber) for removal of Disinfection By-products(DBPs). The primary focus of this study is on the performance of existing filter-adsorber, and their operation. It was found that F/A process removed turbidity as effective as sand system. The ratio of Hydrophobic DOM (HPO) and hydrophilic DOM (HPI) fraction in the raw water at S and B WTP was similar. Filter Adsorber presented earlier DOC breakthrough and steady state condition which was contributed by biodegradation during operation period. The removal efficiency of DBPs were used to evaluate the filter performance. The DBPs concentration of F/A treated water was below treatment goal level (THM < $80\;{\mu}g/L$, HAA < $60{\mu}g/L$). The removal efficiency of THM decreased rapidly during operation period. However, HAA were removed steadily regardless of the influent concentration of HAA. These results indicate that the removal of THM depend upon the adsorption mechanism while the removal of HAA depend upon biodegradation as well as adsorption. The decrease of adsorption capacity and characteristic value of GAC may be attributed to the effect of high organic loading, residual free chlorine, coagulants, manganese oxidants and frequently backwashing. This study has confirmed that Filter adsorber process can be considered as effective alternatives for the removal of DBPs, especially HAA.

Characteristics of Exposure Distribution to Hazard Factors in Indoor Swimming Pool Activity Areas in Gwangju (수영장 활동공간 내 유해인자 노출특성 연구)

  • Lee, Youn-Goog;Kim, Nan-Hee;Choi, Young-Seop;Kim, Sun-Jung;Park, Ju-Hyun;Kang, Yu-Mi;Bae, Seok-Jin;Seo, Kye-Won;Kim, Jong-Min
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.150-158
    • /
    • 2020
  • Objective: This study is designed to measure the concentration of DBPs (disinfection by-products) in pool water and in air and to estimate the carcinogenic potential through the evaluation of inhalation exposure. Methods: The subjects were six indoor swimming pools with many users in Gwangju. Samples of pool water and indoor air were taken every one month from August 2018 to August 2019 and analyzed for eight swimming pool standards. Three-liter air samples were collected and the VOCs were analyzed using GC/MS directly connected to thermal desorption. Results: pH was 6.8-7.5 and the concentration of free residual chlorine in pool water was 0.40-0.96 ?/ℓ. Physicochemical test items such as KMnO4 consumption and heavy metal items such as Aluminum met existing pool hygiene standards. No VOC materials were detected except for the DBPs. The concentration of THMs in the pool water was 11.05-41.77 ㎍/L and the THMs mainly consist of Chloroform (63-97%) and BDCM (3-31%). The concentration of indoor air THMs is 13.24-32.48 ㎍/㎥ and consists of Chloroform. The results of carcinogenic assessment of chloroform in the indoor swimming pool via inhalation exposure were 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA. Conclusions: The concentration of THMs in the pool water is 11.05-41.77 ㎍/L, most of which is chloroform. In addition, the concentration of indoor air THMs is 13.24-32.48 ㎍/㎥. The result of carcinogenic assessment of chloroform was 2.0 to 6.4 times higher than the 'acceptable risk level' suggested by the US EPA.

Neutral Electrolyzed Water for Prevention of Dental Caries (기존 구강청결제를 대체할 수 있는 치아우식 예방을 위한 전기분해수)

  • Lee, Kyam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.3
    • /
    • pp.306-312
    • /
    • 2016
  • Gargle solution has typically been used for the prevention of oral infectious disease such as dental caries and periodontitis. However, the use of most gargle solutions is controversial in application for children because some gargle solutions have harmful side effects. Electrolyzed water is generated by passed an electric current and has antimicrobial activity. The purpose of this study was to investigate and compare the efficacy of electrolyzed water in various conditions for eliminating cariogenic bacteria. Electrolyzed water was generated by a platinum electrode in the presence of sodium chloride at various concentrations. Streptococcus mutans and Streptococcus sobrinus were cultivated into a brain heart infusion broth. After harvesting planktonic bacteria, the pellets were treated with the electrolyzed water and commercial gargle solutions and plated on a mitis-salivarius agar plate. Also, the anti-biofilm activity of the electrolyzed water and commercial gargle solutions was investigated after biofilm formation of S. mutans and S. sobrinus. The bacteria in the biofilm were plated onto a mitis-salivarius agar plate. The plates were incubated, and the colony forming unit was measured. The electrolyzed water containing sodium chloride showed significant antibacterial activity against S. mutans and S. sobrinus as well as some gargle solutions. Furthermore, the electrolyzed water had more disruptive effect on the biofilm of S. mutans and S. sobrinus and killed more bacteria in the biofilm than commercial gargle solutions. The results demonstrate that electrolyzed water may be a useful gargle solution for prevention of dental caries.

Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju (광주지역 바닥분수의 수질특성 평가)

  • Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.2
    • /
    • pp.143-156
    • /
    • 2017
  • The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.