EFFECTS OF MOISTENING OF ETCHED DENTIN AND ENAMEL SURFACES ON BOND STRENGTH (산 표면처리후 상아질과 법랑질 표면의 습윤이 결합강도에 미치는 영향)
-
- Restorative Dentistry and Endodontics
- /
- v.20 no.1
- /
- pp.328-341
- /
- 1995
I. Shear Bond Strength to Air-dried and Remoistened Dentin.. The effect of air-drying and remoistening of acid-conditioned dentin before priming with the primer of All-Bond 2(BISCO. INC., U. S. A.) on shear bond strength(SBS) was investigated. Ninty freshly extracted sound human molars were divided at random into 9 groups of 10 teeth each. SBSs were meaured for acid-conditioned and non-conditioned dentin to which the primer and bonding agent of All-Bond 2 and composite resin(Z-100, 3M Dental Products, U. S. A.) were applied. The following values(Mean
The aims of the present study were to characterize the effect of glucocorticosteroids (GCs) on the normal canine skin and to evaluate the effect of a lipid mixture (LM), containing cholesterol, pseudoceramide, and free fatty acid, on the steroid-induced damaged skin of dogs. Five beagles were involved and the skin of the back of each dog was topically applied with four kinds of GCs twice daily for 28 days. LM was applied after that period of GCs application. Transepidermal water loss (TEWL), skin hydration, and skin pH were assessed during experimental periods and histopathological evaluation was performed. TEWL was significantly increased, with a maximum increase obtained on day 28 (p < 0.01). Skin pH was significantly decreased, with a maximum decrease obtained on day 28 (p < 0.01). Skin surface hydration was significantly increased on day 3, but values of skin hydration were progressively decreased and finally reached those of baseline. In histology, as results of steroid application, losses of keratin layers in the stratum corneum and edematous changes in the upper parts of dermis, and consequently, thickness of the epidermis and the stratum corneum were decreased. In addition, the numbers of hair follicles were markedly decreased in steroid control as compared to intact control. However, these skin atrophic changes were markedly inhibited by treatment of LM as compared with steroid control in the present study. Moreover, all biophysical parameters were reached to the baseline after LM treatment. These results showed that the topically applied GCs induced skin barrier impairment and a LM should be effective on repair of disturbed skin barrier function in dogs. Therefore, it is concluded that a LM tested in the present study is expected to treat the steroid-induced skin damages.
Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.
Purpose: This study was assessed to investigate adverse effect induced by overuse of disposable soft contact lenses (CL). Methods: Three disposable lenses (etafilcon A, hilabilcon A, and nelfilcon A) were applied to 19 normal subjects free from any eye diseases for either a single day or variable periods by when subjects complained any discomforts. On the first and last days, localizations of lens' center on corneal surface and blink rates were recorded at every case. Results: Among CL wearers, 10.5% and 47.4% of total subjects quit wearing on the second day and third day, respectively. The case of stopping disposable lens wear was continuously increased with extended hour of lens application. On fourth day, 70.2% of CL wearers reported severe discomforts such as redness, dryness, irritation, pain and blurred vision. When subjects stopped CL wear, decentration of lens from the center of cornea was observed when it compared to the case of single usage of disposable CL. Also about 80% of total subjects showed increased blink rate when CL were worn for more than 2 days. These changes in lens centration and blink rate were consistantly shown regardless of lens types. Conclusions: Blurred vision and acute/chronic discomforts could occur to CL wearers by decentration of lens and increased blink rate when CL were overused more than 2 days even the numbers of two parameters measured in this study were variable by each subject or lens types. Therefore, consideration of individual characteristics and lens types is critical to prevent adverse effects may induced by overusage of disposable lens.
After making tea by steaming the Burdock(Arctium lappa) nine times and drying it nine times, the ingredients and functions of the Burdock tea were compared to those of M company. The tea's calories were 346.48kcal/100g, carbohydrates were 72.75g/100g, crude protein was 11.98g/100g, and crude ash was 5.01g/100g. The total of free sugars were 31.93mg/100, among them, fructose was 26.27, sucrose was 1.27 mg/100g. The inorganic material contents were 1,476.21mg/100g of potassium, 255.96 mg/100g of calcium and 311.41 mg/100g of magnesium. The saturated fatty acids were 40.73mg/100g and the unsaturated fatty acids were 59.27mg/100g, among which the linoleic acid was 41.28mg/100g, the palmitic acid was 33.11mg/100g, the oleic acid was 10.07mg/100g and linolenic acid was 7.92mg/100g. DPPH radical scavenging was 33.9% of teas that were developed, 2.3% of M's tea for comparison, and 37.2% of indiex material. ABTS radical scavenging were 90.7% of teas developed, 85.9% of M's tea and 37.2% of index materials, and SOD like activities were 11.3% of teas developed and 50.5% of M's teas. The flavonoid content was 2.6 fold of the tea developed, 2.9 fold of M's tea and 1.7 fold of index material. The polyphenol content was 33.8 fold of teas developed, 38.9 fold of the M's tea and 13.8 fold of the index material. The sensory evaluation compare to the one-time extract and the five-time extract. Based on the one-time extract, the color were 65.9 % of the five-time extract tea were developed, 12.8 % of the M's tea. Flavour were 78.0% of the tea developed and 33.3% of the M's tea, tastes were 71.4% of the tea developed, 20.7% of the M's tea. The cart for comparison showed that while the extract decreased as we developed it, the overall symbolism decreased to 21.4% after five time extracts, the developed tea decreased to 72.1%. We believe that the developed tea will have a greater effect on preventing and improving diseases as it has a stronger antioxidant function, more effective substances, and a higher level of symbolism than the comparative M squared tea and surface substance.
Hibiscus hamabo Sieb. et Zucc. (yellow hibiscus) is a deciduous semi-shrub plant and mainly growing in Jeju Island. This is known the unique wild hibiscus genus and classified as an 2nd grade of endangered plant for Korean Red List. In previous studies, properties of germination, ecological, genetical and salt resistance have been reported. In this study, we investigated mass-proliferated adventitious root using bioreactor, antioxidant and whitening effects to conduct functional ingredients. Yellow hibiscus were collected from Gujwa, Jeju by prior permission and they were introduced by explant type and various medium composition after surface sterilization. As a result, seed response rates were evaluated at range of 51.17~51.83%, in terms of comprehensive efficiency of shoot and root formation. In the case of adventitious root propagation condition was confirmed in half strength Murashige and Skoog medium salts, 30 mg/L sucrose, and 2 mg/L indole-3-butyric acid for 8 weeks in 5,000 mL bioreactor. We also compared between relationship with biomass and secondary metabolites accumulation by total phenolics content, the flavonoid content, DPPH free radical scavenging activity and melanin content. The results indicated that adventitious root mass proliferation, antioxidant and whitening effect could develop value of the high-quality cosmeceutical ingredient and further metabolite studies.
This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The studies were carried out to disclose the physical and chemical properties of sericin fraction obtained from silk cocoon shells and its characteristics of swelling and solubility. The following results were obtained. 1. The physical and chemical properties of sericin fraction. 1) In contrast to the easy water soluble sericin, the hard soluble sericin contains fewer amino acids include of polar side radical while the hard soluble amino acid sach as alanine and leucine were detected. 2) The easy soluble amino acids were found mainly on the outer part of the fibroin, but the hard soluble amino acids were located in the near parts to the fibroin. 3) The swelling and solubility of the sericin could be hardly assayed by the analysis of the amino acid composition, and could be considered to tee closely related to the compound of the sericin crystal and secondary structure. 4) The X-ray patterns of the cocoon filament were ring shape, but they disappeared by the degumming treatment. 5) The sericin of tussah silkworm (A. pernyi), showed stronger circular patterns in the meridian than the regular silkworm (Bombyx mori). 6) There was no pattern difference between Fraction A and B. 7) X-ray diffraction patterns of the Sericin 1, ll and 111 were similar except interference of 8.85A (side chain spacing). 8) The amino acids above 150 in molecular weight such as Cys. Tyr. Phe. His. and Arg. were not found quantitatively by the 60 minutes-hydrolysis (6N-HCI). 9) The X-ray Pattern of 4.6A had a tendency to disappear with hot-water, ether, and alcohol treatment. 10) The partial hydrolysis of sericin showed a cirucular interference (2A) on the meridian. 11) The sericin pellet after hydrolysis was considered to be peptides composed with specific amino acids. 12) The decomposing temperature of Sericin 111 was higher than that of Sericin I and II. 13) Thermogram of the inner portioned sericin of the cocoon shell had double endothermic peaks at 165