• Title/Summary/Keyword: Frame structure

Search Result 2,436, Processing Time 0.032 seconds

Development of Efficient Seismic Analysis Model using 3D Rigid-body for Wall-Frame Structures with an Eccentric Core (삼차원 T형강체를 이용한 편심코어를 가진 전단벽-골조 구조물의 효율적인 지진해석모델 개발)

  • Park, Yong-Koo;Lee, Dong-Guen;Kim, Hyun-Su
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • In a shear wall-frame structural system, the structural response is determined by the interaction between the shear wall in bending mode and the frame in shear mode. In order to effectively consider these characteristics of a shear wall-frame structure, the simplified numerical model using the T-shape rigid body was suggested in the previous study. Based on the previously proposed model, an efficient numerical model for a wall-frame structure with an eccentric core has been proposed in this study. To this end, the previously proposed 2D model is extended to the 3D model and it is enhanced by considering torsion effects. As a result, the enhanced model can be applied to the analysis of a wall-frame structure with an eccentric core as well as a centric core.

Simplified robustness assessment of steel framed structures under fire-induced column failure

  • Jiang, Binhui;Li, Guo-Qiang;Yam, Michael C.H.
    • Steel and Composite Structures
    • /
    • v.35 no.2
    • /
    • pp.199-213
    • /
    • 2020
  • This paper proposes a Global-Local Analysis Method (GLAM) to assess the progressive collapse of steel framed structures under fire-induced column failure. GLAM obtains the overall structural response by combining dynamic analysis of the heated column (local) with static analysis of the overall structure (global). Test results of two steel frames which explicitly consider the dynamic effect during fire-induced column failure were employed to validate the proposed GLAM. Results show that GLAM gives reasonable predictions to the test frames in terms of both whether to collapse and the displacement verse temperature curves. Besides, several case studies of a two-dimensional (2D) steel frame and a three-dimensional (3D) steel frame with concrete slabs were conducted by using GLAM. Results show that GLAM gives the same collapse predictions to the studied cases with nonlinear dynamic analysis of the whole structure model. Compared with nonlinear dynamic analysis of the whole structure model, GLAM saves approximately 70% and 99% CPU time for the cases of 2D and 3D steel frame, respectively. Results also show that the load level of a structure has notable effects on the restraint condition of a heated column in the structure.

A Study on the Development of Sub-frame Designe Using Tailor Welded Blanks (Tailor Welded Blanks를 이용한 승용차용 Sub-frame의 설계기법 연구)

  • Jeon, Byung-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.22-30
    • /
    • 2000
  • The sub-frame of passenger car begins to be used widely for the safety of passengers. Conventional design of the sub-frame comprises 22parts, and it requires quite complicated production processes. In this papers, the sub-frame is designed with TWB(Tailor Welded Blanks) to improve stiffness, to reduce weight and to simplify the manufacturing process. To design the proper structure, structural analysis and crash analysis are executed about the conventional design and TWB applied design. A prototype TWB applied sub-frame is manufactured using mash-seam welded TB(Tailored Blanks). Comparing with the conventional sub-frame, the TWB applied sub-frame has 30% weight reduction and 17% increasement of structural stiffness in average.

  • PDF

Improved H.263+ Rate Control via Variable Frame Rate Adjustment and Hybrid I-frame Coding

  • 송환준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.726-742
    • /
    • 2000
  • A novel rte control algorithm consisting of two major components, i.e. a variable encoding frame rate method and a hybrid DCT/wavelet I-frame coding scheme, is proposed in this work for low bit rate video coding. Most existing rate control algorithms for low bit rate video focus on bit allocation at the macroblock level under a constant frame rate assumption. The proposed rate control algorithm is able to adjust the encoding frame rate at the expense of tolerable time-delay. Furthermore, an R-D optimized hybrid DCT/wavelet scheme is used for effective I-frame coding. The new rate-control algorithm attempts to achieve a good balance between spatial quality and temporal quality to enhance the overall human perceptual quality at low bit rates. It is demonstrated that the rate control algorithm achieves higher coding efficiency at low bit rates with a low additional computational cost. The variable frame rate method and hybrid I-frame coding scheme are compatible with the bi stream structure of H.263+.

  • PDF

A Study for Web Frame Design on Engine Room Structure of Ship (선박기관실 구조의 특설늑골 설계에 대한 연구)

  • J.J. Park;B.S. Kang
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.155-160
    • /
    • 1993
  • A design method for web frame scantling on engine room structures was described. The parameters determining the scantling of web frame were studied on the basis of the empirical ship's data. It is found that the parameters determining the scanting of web frame consist of tween deck height, main engine and propeller excitation frequency, scantling draft, web frame spacing, the number of decks and main engine BHP etc. And a formula proposed by empirical ship's data was established in view points of static and dynamic structural behavior. In this study, it can be shown that at initial design stage, a method for web frame scantling of engine room structure is provided as very practical design processes.

  • PDF

Design of Zigbee Beacon Frame for High Efficiency Transmit in Home Network (홈 네트워크에서 고효율 전송을 위한 Zigbee Beacon Frame 설계)

  • Han, Kyoung-Heon;Han, Seung-Jo;Choi, Hyun-Yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.11B
    • /
    • pp.1373-1382
    • /
    • 2011
  • Zigbee is communication technology most ideal because Zigbee support low power communication and wide expansion in wireless home network. However, Zigbee is not popular, because of Zigbee always has Hidden Node Problem and Transit Delay Problem. We propose new Beacon Frame structure to solve the two problem in Zigbee. New Beacon Frame structure reduces a Super Frame Duration and add a same space of a Control Frame Duration. We expect to solved method of Hidden Node Problem that exchange terminal information to using RTS/CTS. Also, We expect to solved method of Transit Delay Problem that put Beacon between Control Frame Duration and Super Frame Duration for synchronization. We confirm new Beacon Frame to solved two problem in OPNET simulation at Zigbee QoS Parameters. We measure Delay(sec) for solution degree of Transit Delay Problem, and measure Throughput(bits/sec) and Load (bits/sec) for solution degree of Hidden Node Problem.

Study on response of a new double story isolated structure under earthquakes

  • Hang Shan;Dewen Liu;Zhiang Li;Fusong Peng;Tiange Zhao;Yiran Huo;Kai Liu;Min Lei
    • Earthquakes and Structures
    • /
    • v.27 no.1
    • /
    • pp.17-29
    • /
    • 2024
  • The traditional double story isolated structure is a derivative of the base isolated and inter-story isolated structures, while the new double story isolated structure represents a novel variation derived from the traditional double story isolated structure. In order to investigate the seismic response of the new double story isolated structure, a comprehensive structural model was developed. Concurrently, models for the basic fixed, base isolated, inter-story isolated, and traditional double story isolated structures were also established for comparative analysis. The nonlinear dynamic time-history response of the new double story isolated structure under rare earthquake excitations was analyzed. The findings of the study reveal that, in comparison to the basic fixed structure, the new double story isolated structure exhibits superior performance across all evaluated aspects. Furthermore, when compared to the base isolated and inter-story isolated structures, the new double story isolated structure demonstrates significant reductions in inter-story shear force, top acceleration, and inter-frame displacement. The horizontal displacement of the new double story isolated structure is primarily localized within the two isolation layers, effectively dissipating the majority of input seismic energy. In contrast to the traditional double story isolated structure, the new design minimizes displacements within the inter-isolation layer situated in the central part of the frame, as well as mitigates the overturning forces acting on the lower frame column. Consequently, this design ensures the structural integrity of the core tube, thereby preventing potential collapse and structural damage.

An absolute displacement approach for modeling of sliding structures

  • Krishnamoorthy, A.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.6
    • /
    • pp.659-671
    • /
    • 2008
  • A procedure to analyse the space frame structure fixed at base as well as resting on sliding bearing using total or absolute displacement in dynamic equation is developed. In the present method, the effect of ground acceleration is not considered as equivalent force. Instead, the ground acceleration is considered as a known value in the acceleration vector at degree of freedom corresponding to base of the structure when the structure is in non-sliding phase. When the structure is in sliding phase, only a force equal to the maximum frictional resistance is applied at base. Also, in this method, the stiffness matrix, mass matrix and the damping matrix will not change when the structure enters from one phase to another. The results obtained from the present method using absolute displacement approach are compared with the results obtained from the analysis of structure using relative displacement approach. The applicability of the analysis is also demonstrated to obtain the response of the structure resting on sliding bearing with restoring force device.

Analysis of plane frame structure using base force element method

  • Peng, Yijiang;Bai, Yaqiong;Guo, Qing
    • Structural Engineering and Mechanics
    • /
    • v.62 no.1
    • /
    • pp.11-20
    • /
    • 2017
  • The base force element method (BFEM) is a new finite element method. In this paper, a degenerated 4-mid-node plane element from concave polygonal element of BFEM was proposed. The performance of this quadrilateral element with 4 mid-edge nodes in the BFEM on complementary energy principle is studied. Four examples of linear elastic analysis for plane frame structure are presented. The influence of aspect ratio of the element is analyzed. The feasibility of the 4 mid-edge node element model of BFEM on complementary energy principles researched for plane frame problems. The results using the BFEM are compared with corresponding analytical solutions and those obtained from the standard displacement finite element method. It is revealed that the BFEM has better performance compared to the displacement model in the case of large aspect ratio.

Experimental Study of Infilled Wall in Reinforced Concrete Structure (메움벽에 의한 R/C 골조의 내진성능 평가에 관한 연구)

  • 김석균;김정한;김영문
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.403-406
    • /
    • 1999
  • Although infilled wall considered as a non-structural element, the infilled applied in reinforced concrete frame structural systems represents an important element influencing the behaviour and the stability of a structure under seismic effect. This research is performed an experimental investigation of gravity-load designed single-stroy, single-bay, low-rise nonseismic moment-resisting reinforced concrete frame 2 dimension specimens to evaluate the effect of seismic capacity. For pseudo static test, it was manufactured one half scale specimens of two types (Bare Frame, Infilled Frame) based on typical building. The results of these experiments provided regarding the global as well as the local responses of 1) Crack pattern and failure modes, 2) Stiffness, strength.

  • PDF