• Title/Summary/Keyword: Fractures, Comminuted

Search Result 93, Processing Time 0.031 seconds

Sensory Impairment in Infraorbital Nerve Following Mid-Facial Fractures (중안면골절에 따른 안와하신경의 손상)

  • Lee, Hyun-Tae;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Jun-Ho
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.43-47
    • /
    • 2011
  • Purpose: Sensory impairment in infraorbital nerve is common symptom following mid-facial fractures. The purpose of this study is to document the incidence of sensory impairment in infraorbital nerve following midfacial fractures and its recovery. Methods: Three hundreds fourteen patients with midfacial fracture were included involving emergence areas of infraorbital nerve. Fractures were classified into zygoma fracture, maxilla fracture, complex comminuted fracture and pure blow out fracture. Neurosensory function was assessed with clinical symptoms and light touch test in infraorbital nerve regions. Patients were followed and sensory function was evaluated immediately, 1, 3 and 6 months after trauma. Results: The total series consisted of 198 zygoma fractures, 19 maxilla fractures, 30 complex comminuted fractures and 67 pure blow out fractures. The incidence of sensory impairment was 60% (63% in zygoma fractures, 84% in maxilla fractures, 93% in complex comminuted fractures, 31% in pure blow out fractures). Persistent sensory impairments were remained in 32% (33% in zygoma fractures, 47% in maxilla fractures, 73% in complex comminuted fractures, 6% in pure blow out fractures) 6 months after trauma. Younger patients had better prognosis than older patients in recovery of infraorbital nerve function ($p$ <0.05, $x^2$-test). Mean recovery time was 11 weeks. Conclusion: The incidence of post-traumatic sensory impairment was different according to fracture types. Age of patients and fracture type were important factors that influence to recovery of sensory impairment. Complex comminuted fracture had poor prognosis, and pure blow out fractures had better prognosis than other fractures.

Additional fixation using a metal plate with bioresorbable screws and wires for robinson type 2B clavicle fracture

  • Shin, Woo Jin;Chung, Young Woo;Kim, Seon Do;An, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.198-202
    • /
    • 2020
  • Simple clavicle fractures can achieve satisfactory results through conservative treatment, and the less frequency of nonunion. Non-union or malunion can occur in displaced clavicle fractures or comminuted shaft fractures. Treatment of displaced comminuted clavicle shaft fractures is performed by holding together the free fragments with interfragmentary screws or wires and fixing them to the clavicle with a plate. Therefore, we performed interfragmentary fixation using open reduction and internal fixation with bioresorbable screws (Mg-Ca alloy, Resomet bioresorbable bone screw; U&I Corp.) and bioresorbable wires (Mg-Ca alloy, Resomet bioresorbable K-wire and pin, U&I Corp.) for displaced comminuted clavicle fractures (Robinson type 2B) and additionally used a metal plate. We expected decreased irritation and infection due to absorption after surgery. We report four cases that were treated in this way.

TREATMENTS OF COMMINUTED MANDIBULAR FRACTURES (하악골 분쇄골절의 치료)

  • Jeon, Woo-Jin;Kim, Su-Gwan;Kim, Hyeon-Ho;Kim, Hak-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.71-75
    • /
    • 2005
  • This study evaluated retrospectively the treatment method and postoperative complications of communited mandibular fractures. We analyzed the clinical and radiologic data of 14 patients with the comminuted mandibular fractures who were admitted to Chosun University Dental Hospital from January 1998 to December 2003. We reviewed the cause of trauma, fracture sites, treatment methods, and postoperative complications. Thirteen patients (93%) had a successful treatment outcome without complications. Only one patient developed postoperative osteomyelitis requiring early plate removal and sequestrectomy. For the comminuted fractures of mandible, internal fixation using micro- or mini-plate was an effective treatment method with a low incidence of major complications.

Use of resorbable mesh and fibrin glue for restoration in comminuted fracture of anterior maxillary wall

  • Yang, Jae-Hyuk;Chang, Suk Choo;Shin, Jin Yong;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.175-180
    • /
    • 2018
  • Background: The facial bone has a complex structure compared to other bones, and various types of fractures can occur due to its characteristics. Among them, in comminuted fractures of anterior maxillary wall, multiple depressed and impacted bony segments cannot be reduced easily when performing internal fixation using plates and screws or wires, and inadequate restoration leads to a range of complications. This paper introduces an alternative technique using a resorbable mesh with fibrin glue to restore comminuted fractures of anterior maxillary wall. Methods: Thirteen patients were diagnosed with comminuted fractures of anterior maxillary wall between March 2017 and February 2018 in the authors' hospital. All patients with comminuted fractures of anterior maxillary wall underwent restoration using resorbable mesh with fibrin glue. The patients' demographics, causes of facial trauma, mean operation time, length of hospital stay, follow-up period, and complications were recorded. Results: No major complications and only one hypoesthesia of the skin area was noted. Three months after surgery, the hypoesthesia recovered completely. After surgery (mean, 3.9 months; range, 2-12 months), computed tomography showed that the bone fragments in all patients were fixed successfully in their anatomical places. Conclusion: In comminuted fractures of anterior maxillary wall, the use of a resorbable mesh with fibrin glue can be an advantageous and effective method for a successful restoration without complications.

Guided Bone Regeneration in Comminuted Long-Bone Fractures Using Recombinant Human Bone Morphogenetic Protein-2 and a Collagen Membrane

  • Jang, Kwangsik;Jo, Hyun Min;Shim, Kyung Mi;Kim, Se Eun;Kang, Seong Soo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.59-64
    • /
    • 2022
  • A dog aged two years and seven months and a cat aged seven years were referred owing to fractures of long bones. Preoperative radiographs revealed comminuted bone fractures close to joints. Conventionally, long-bone fractures are treated using intramedullary pins, plate and screw systems, or an external fixator system. In cases of non-reducible fractures, various graft materials have been used in fracture treatments to stimulate bone repair. Here, recombinant human bone morphogenetic protein-2 (rhBMP-2) and a collagen membrane were applied. Four weeks after surgery, fractured bone fragments began to unite and the bone union was observed using radiography four months after surgery. No complications occurred related to grafted materials. We successfully applied rhBMP-2 and collagen membranes in two different species to support the healing process of comminuted fractures, according to the concept of guided bone regeneration.

Combined Orbital Fractures: Surgical Strategy of Sequential Repair

  • Hur, Su Won;Kim, Sung Eun;Chung, Kyu Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • v.42 no.4
    • /
    • pp.424-430
    • /
    • 2015
  • Background Reconstruction of combined orbital floor and medial wall fractures with a comminuted inferomedial strut (IMS) is challenging and requires careful practice. We present our surgical strategy and postoperative outcomes. Methods We divided 74 patients who underwent the reconstruction of the orbital floor and medial wall concomitantly into a comminuted IMS group (41 patients) and non-comminuted IMS group (33 patients). In the comminuted IMS group, we first reconstructed the floor stably and then the medial wall by using separate implant pieces. In the non-comminuted IMS group, we reconstructed the floor and the medial wall with a single large implant. Results In the follow-up of 6 to 65 months, most patients with diplopia improved in the first-week except one, who eventually improved at 1 year. All patients with an EOM limitation improved during the first month of follow-up. Enophthalmos (displacement, 2 mm) was observed in two patients. The orbit volume measured on the CT scans was statistically significantly restored in both groups. No complications related to the surgery were observed. Conclusions We recommend the reconstruction of orbit walls in the comminuted IMS group by using the following surgical strategy: usage of multiple pieces of rigid implants instead of one large implant, sequential repair first of the floor and then of the medial wall, and a focus on the reconstruction of key areas. Our strategy of step-by-step reconstruction has the benefits of easy repair, less surgical trauma, and minimal stress to the surgeon.

TREATMENT OF COMPOUND COMMINUTED MANDIBULAR FRACTURES (하악골 복합 분쇄 골절의 치험례)

  • Jeong, Jong-Cheol;Kim, Keon-Jung;Choi, Jae-Sun;Sung, Dae-Kyung;Kim, Ho-Sung;Lee, Gye-Hyeok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.2
    • /
    • pp.101-105
    • /
    • 1998
  • Compound comminuted mandibular fracture is defined as the presence of multiple fracture lines with open wound resulting in many small pieces within the same area. The incidence of mandibular comminution is difficult to determine but reported as 2.7~18.6 % incidence among mandibular fractures. There are controversies in the treatment of mandibular comminuted fractures. Treatment of comminuted mandibular fracture has traditionally involved closed reduction in an effort to avoid stripping periostcum from the bony segments, but rigid internal rigid fixation is used more popular at present. The extent of comminution, displacement of bony fragments and patient general conditions are important factors in decision of the treatment methods. When significant bone displacement is present, it is necessary to reduce these comminuted fragments to an anatomic, pretraumatic relationship to restore facial form and function. In these cases, ORIF allows anantomic reduction of comminuted segments as well as pretraumatic occlusion. Gentle handling of the soft tissue, rigid fixation of bony fragments and adequate immobilization are essential for reducing the complications. This is the report the incidence, causes, complications and treatment of the patients who visited our department for compound comminuted mandibular fractures.

  • PDF

Subservient Bone Reduction with Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate) in Hand Fractures: Two Cases of Report (수부 골절 시 Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate)을 이용한 보조적 골 정복 2례)

  • Lee, Won;Lee, Sung-Hwan;Oh, Sang-A;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.102-104
    • /
    • 2011
  • Purpose: The standard treatments of hand fractures today are fixations by K -wires, metal plates, wires and lag screws. But it is very difficult to reconstruct fractures by placing implants into small bony fragments especially in the comminuted fractures and intra-articular fractures. This paper describes a simple method of reconstruction with Histoacryl$^{(R)}$ for comminuted and intra-articular fractures in hands. Methods: 2 cases with comminuted and intra-articular fractures by crushing injury were reconstructed with Histoacryl$^{(R)}$. We performed applying Histoacryl$^{(R)}$ with swab on the bone cortex carefully to avoid Histoacryl$^{(R)}$ infiltrating into the medulla. We could rearrange and fixate bony fragments using only Histoacryl$^{(R)}$, in addition, metal plates, K-wires, wires, and lag screws could be used for secondary fixation if needed. Results: Post-operative X-ray finding of 2 patients assured that the bony fragments of the hand fractures maintained their original positions. Significant displacement and deviation, infection, nonunion, and malunion during the follow-up period were not observed. Conclusion: This study showed the possibility of using Histoacryl$^{(R)}$ in addition as a simple method of fixation in the comminuted and intra-articular hand fractures.

Clinical usefulness of fixation of absorbable implants with cyanoacrylate in comminuted fractures of the maxilla

  • Ju, Gang San;Son, Kyung Min;Choi, Woo Young;Cheon, Ji Seon
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.4
    • /
    • pp.233-238
    • /
    • 2019
  • Background: The open reduction of craniofacial bone fractures requires internal fixation using metal plates and screws, which have been considered the gold standard. However, metal implants pose a risk of palpation, protrusion, and foreign body reaction, and they may require an additional operation for removal. Recently, good results have been reported for absorbable implants which complement the disadvantages of metal implants. This study presents the results of using absorbable mesh, plates, and screws with cyanoacrylate for more accurate and firmer fixation of comminuted fractures of the maxilla. Methods: In total, 235 patients underwent operations for comminuted fractures of the maxilla. From January 2012 to December 2014, absorbable mesh and screws were used in 114 patients, while from January 2015 to December 2017, absorbable mesh, plates, and screws with cyanoacrylate were used in 121 patients. Open reduction of the bone fragments was performed, after which absorbable implants were accurately molded and fixed by screws. Results: All patients underwent postoperative computed tomography scans, which showed highly accurate reduction and firm fixation in the patients who underwent procedures using absorbable implants, screws, and cyanoacrylate. There were no postoperative complications or cases of abnormal facial contour. Conclusion: When absorbable implants and screws are used for maxillary fractures, no additional surgery to remove the metal plate is required. In addition, the use of cyanoacrylate enables accurate and firm fixation of the tiny bone fragments that cannot be fixed with screws.

Transosseous Tie Fixation Using Krackow Sutures and Bone Tunnels in a Comminuted Fracture of the Upper Pole of the Patella: A Case Report

  • Baik, Jong Seok
    • Journal of Trauma and Injury
    • /
    • v.34 no.4
    • /
    • pp.305-308
    • /
    • 2021
  • Comminuted fractures of the patella mostly occur at the inferior pole and require appropriate reduction and fixation to restore the extensor mechanism. Conventional methods such as tension-band wiring are not enough to gain proper fixation strength. Numerous methods have been reported, including circumferential cerclage wiring, osteosynthesis, and suture anchors depending on the fracture pattern. Herein, the author reports a relatively rare case of a comminuted fracture of the upper pole of the patella, for which we used augmented Krackow sutures in the quadriceps and fixation with tying of the suture limbs through patellar bone tunnels. Satisfactory results were obtained in terms of reduction and extensor mechanism recovery.