• 제목/요약/키워드: Fracture protect effect

검색결과 8건 처리시간 0.022초

수종의 마우스가드에 대한 파절방지효과 비교 (Experimental Study on Fracture Protect Effect in Mouthguards)

  • 김남중;김소민
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.31-38
    • /
    • 2009
  • In recent year, the population for sports has been increased and lots of wounded patients at the oral & facial portion were troubled with the accidents. So, it was needed to protect them from the sports accident, by the use of the mouthguard appliance. This study was done as ae guide for selection of the mouthguard materials. Such mouthguards classified as E.V.A., PE, silicone as material, Scheu(Germany), Tru-Tain(U.S.A.), Dreve(Germany) as companies, 1.5mm, 3.0mm, and 4.0mm as thickness and single sheet, soft double sheet, hard double sheet methods were selected for experiment to compare the fracture protect test. The obtained results are as follows. 1. All types of mouthguards, whatever differences there are in material, production company, procedure and the thickness, were effective for fracture protect effect. 2. The most effective one for fracture protection was recommended as E.V.A. in material, and Tru-Tain in company. 3. More thick, and soft & hard multi sheets productions were more effective for fracture protection.

  • PDF

전력용 피뢰기의 임펄스에 의한 파손과 대척 기술 (Fracture and Protection Technologies against Impulse of Power Arresters)

  • 한세원;조한구;김석수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.190-193
    • /
    • 2001
  • ZnO varistors have been widely used to protect power system and electronic system against overvoltages based on their excellent nonlinearity. In order to increase their protection capability, the fracture and protection technologies of arresters have to study according to their applications, namely ImA DC voltage, leakage currents, impulse residual voltages, withstanding capability to impulse surge, and energy absorption capability. ZnO varistors which have nonlinear current-voltage characteristic name a number of failure mechanism when ZnO elements absorb surge energies. Failure mode by thermal stress and Pin hole are among the most common failure mechanism at the high current surge current. In this study, the fracture mechaism of power arresters are introduced and protection technologies are researched. In particular the effect of thermal stress by surge currents to ZnO elements and methods against arc surge energy through withstand structure design of arrester are discussed.

  • PDF

열하중하에 있는 IC 패키지의 점탄성 파괴해석 (Visco-Elastic Fracture Analysis of IC Package under Thermal Loading)

  • 이강용;양지혁
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.43-50
    • /
    • 1998
  • The purpose of the paper is to protect the damage of plastic IC package with searching the cause of the fracture due to the delamination and crack when the encapsulant of plastic IC package is on viscoelastic behavior with the effect of creep on high temperature, The model for analysis is the plastic SOJ package with dimpled diepad in the IR soldering process of surface mounting technology. The risk of delamination with calculating the distribution of viscoelastic thermal stress in the package without the crack in the surface mounting process is checked. The package model with the perfect delamination between chip and diepad is chosen to estimate the resistance against fracture in thermal loading with calculating C (t)-integrals according to the change of the design. The optimum design to depress the delamination and crack is presented.

  • PDF

Biomechanical Effect of In-line Skating Wrist Guards on the Prevention of Wrist Fracture

  • Lim, Tae-Hong;Linda M. McGrady;Peter Hoepfner;Craig C. Young;William G. Raasch;Han, Jung-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.1072-1076
    • /
    • 2001
  • A biomechanical study was conducted in this study to investigate if in-line skating wrist guards can effectively reduce the impact forces so as to protect the wrist from fracture. The forearm specimens with and without wrist guards were dropped using a specially designed sled to simulate the impact on the wrist while falling. A force plate was used to measure the total impact force on the dropping weight whereas a load cell was attached to the proximal end of the specimen and used to quantify the impact transmitted through the wrist joint. From the non-destructive tests, mean peak force measured from a force plate showed no difference between the guarded and unguarded groups whereas mean impulse of the guarded group was significantly greater than that of the unguarded group (p<0.01). Comparing the peak force and impulse measured from the load cell, the peak force of the guarded group was significantly less than that of the unguarded group (p<0.001), while the impulse values were similar. When the specimens were dropped from a higher position (2.5ft ve. 1ft), all unguarded specimens had severe wrist fractures whereas fracture was found in three out of 5 guarded specimens. Comparison of mean peak forces and impulses showed as significant difference between the guarded and unguarded groups only in the mean impulse measured from the force plate. These results suggest that the wrist guard may protect the wrist by attenuating the peak force transmitted to radius and ulnar although it may not be effective when the wrist is subjected to an impact sufficiently large to cause fractures.

  • PDF

변형된 임플란트 임시 지대주의 물성에 대한 연구 (The Study on the Physical Property of Provisional Prosthesis using Modified Temporary Abutment)

  • 양병덕;윤태호;최운재;박주미
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.329-340
    • /
    • 2006
  • Statement of problem: Damping of the peak force transmitted to implants has been reported by in vitro studies using impact forces on resin-veneered superstructures. Theoretical assumptions suggest that use of acrylic resin for the occlusal surfaces of a prosthesis would protect the connection between implant and bone. Therefore, the relationship between prosthesis materials and the force transmitted through the implant system also needs to be investigated under conditions that resemble the intraoral mechanical environment. Purpose: The purpose of this study was to analyze the fracture strength and modes of temporary prosthesis when a flange or occlusally extended structure were connected on the top of the abutment. Material and method: Modified abutments of winged and bulk design were made by casting the desired wax pattern which is made on the UCLA type plastic cylinder. Temporary crowns were made using templates on the modified abutments, and its fracture toughness and strain were compared to the traditional temporary prosthesis. To evaluate the effect of aging, 5.000 times of thermocycling were performed, and their result was compared to the 24hours specimen result. Results: The following conclusions were drawn from this study: 1. In the fracture toughness test, temporary crown's fracture line located next to the screw hole while modified designs with metal support showed fracture line on the metal and its propagation along the metal-resin interface. 2. Wing and bulk structure didn't show significant difference in the fracture toughness (p>0.05), but wing structure showed stress concentration on the screw hole area compared to bulk structure which showed even stress distribution. 3. In the fracture toughness test after thermocycling, wing and bulk structure showed increased or similar results in metal supported area while off-metal area and temporary crown showed decreased results. 4. In the strain measurement after thermocycling, its value increased in the temporary and bulk structure. However, wing structure showed decreased value in the loading point while increased value in the screw hole area. Conclusion: Wing type design showed compatible result to the bulk type that its application with composite resin prosthesis to the implant dentistry is considered promising.

HF 습식 식각을 이용한 극자외선 노광 기술용 SiNx (Manufacturing SiNx Extreme Ultraviolet Pellicle with HF Wet Etching Process)

  • 김지은;김정환;홍성철;조한구;안진호
    • 반도체디스플레이기술학회지
    • /
    • 제14권3호
    • /
    • pp.7-11
    • /
    • 2015
  • In order to protect the patterned mask from contamination during lithography process, pellicle has become a critical component for Extreme Ultraviolet (EUV) lithography technology. According to EUV pellicle requirements, the pellicle should have high EUV transmittance and robust mechanical property. In this study, silicon nitride, which is well-known for its remarkable mechanical property, was used as a pellicle membrane material to achieve high EUV transmittance. Since long silicon wet etching process time aggravates notching effect causing stress concentration on the edge or corner of etched structure, the remaining membrane is prone to fracture at the end of etch process. To overcome this notching effect and attain high transmittance, we began preparing a rather thick (200 nm) $SiN_x$ membrane which can be stably manufactured and was thinned into 43 nm thickness with HF wet etching process. The measured EUV transmittance shows similar values to the simulated result. Therefore, the result shows possibilities of HF thinning processes for $SiN_x$ EUV pellicle fabrication.

Nutritional Functions of Milk and Dairy Products in Improving Human Health

  • Chon, Jung-Whan;Kim, Hyunsook;Kim, Dong-Hyeon;Lee, Soo-Kyung;Kim, Hong-Seok;Yim, Jin-Hyuk;Song, Kwang-Young;Kim, Young-Ji;Kang, Il-Byung;Jeong, Dana;Park, Jin-Hyeong;Jang, Ho-Seok;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • 제34권3호
    • /
    • pp.145-155
    • /
    • 2016
  • Cow's milk and dairy products are elements of the human diet that could play an important role in improving human health. The macronutrients and micronutrients found in milk could supply the nutrients required to maintain human health. Among them, milk-derived bioactive peptides have been identified as potential ingredients found in health promoting functional foods. These bioactive peptides target diet-related chronic diseases, particularly non-communicable ones such as cardiovascular disease, diabetes and obesity. Additionally probiotics such as lactic acid bacteria (LAB) are can be considered live microorganisms that confer health benefits for the host-, when administered in adequate amounts. Further, the calcium, vitamin D, and protein content of milk and dairy products could play a role in proving bone health. The effect of milk and calcium on bone mineral density could prevent against fracture, osteoporosis and rickets. Furthermore, milk and dairy products also contain which factors that, which protect against dental caries (anti-cariogenic properties). This paper reviews the various nutritional functions of milk and dairy products in improving human health.

지하수오염방지 시설기준의 개선에 관한 연구:지하수오염관정에의 팩커그라우팅 적용사례 (A Study on Improving Installation Guideline of Facilities to Protect Groundwater Contamination: Applications of Packer Grouting to Contaminated Wells)

  • 추창오;류종흠;조희남;정교철
    • 지질공학
    • /
    • 제23권3호
    • /
    • pp.293-304
    • /
    • 2013
  • 국내 현행 지하수법에서는 오염방지 시설에 관한 개략적인 설치규정만이 설정되어 있어서 대수층의 특성을 고려하지 않은 일률적인 오염방지 시설 기준이므로 지질에 따라 다양하게 발달하는 우리나라의 지하수자원을 효과적으로 보호해 주지 못한다. 최근에는 지하수오염방지에 중요한 기술과 장치로서 패커개발이 점차 주목을 받고 있다. 본 연구에서는 경북 안동시 서후면, 충남 연기군의 오염된 지하수공에 대하여 하부지하수오염방지시설로서 팩커의 적합성을 검토한 결과, 그 효과는 우수한 것으로 나타났다. 연구대상지인 경북 안동시 서후면 창풍리의 경우 팩커를 시공한 결과 탁도는 94%, 연기군 남면 눌왕리의 경우 질산성 질소는 60% 감소효과를 나타내었으며, 이로 인해 모든 수질검사항목에서 적합수질을 보였다. 지하수오염방지를 위해서는 정확한 관정카메라 촬영과 오염원 모니터링 분석을 실시하고, 이에 근거하여 지질특성, 풍화대심도, 파쇄대 발달, 대수층의 수리경사, 오염물의 이동경로를 파악한 후, 통합적으로 지하수오염 가능성을 평가하고, 이를 통하여 적절한 그라우팅과 케이싱 작업이 이루어져야 한다. 유용한 대수층 구간을 확보하여 오염물을 차단하는 그라우팅, 팩커장치, 케이싱은 지하수의 활용과 오염방지에 중요한 역할을 할 것으로 기대된다.