• Title/Summary/Keyword: Fracture Recovery

Search Result 200, Processing Time 0.027 seconds

Improvement of Infraorbital Rim contour Using Medpor

  • Hwang, So Min;Park, Seong Hyuk;Lee, Jong Seo;Kim, Hyung Do;Hwang, Min Kyu;Kim, Min Wook
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.2
    • /
    • pp.77-81
    • /
    • 2016
  • Background: Asymmetry of the infraorbital rim can be caused by trauma, congenital or acquired disease, or insufficient reduction during a previous operation. Such asymmetry needs to be corrected because the shape of the infraorbital rim or midfacial skeleton defines the overall midfacial contour. Methods: The study included 5 cases of retruded infraorbital rim. All of the patient underwent restoration of the deficient volume using polyethylene implants between June 2005 and June 2011. The infraorbital rim was accessed through a subciliary approach, and the implants were placed in subperiosteal space. Surgical outcomes were evaluated using preoperative and postoperative computed tomography studies. Results: Implant based augmentation was associated with a mean projection of 4.6 mm enhancement. No postoperative complications were noted during the 30-month follow-up period. Conclusion: Because of the safeness, short recovery time, effectiveness, reliability, and potential application to a wide range of facial disproportion problems, this surgical technique can be applied to midfacial retrusion from a variety of etiologies, such as fracture involving infraorbital rim, congenital midfacial hypoplasia, lid malposition after blepharoplasty, and skeletal changes due to aging.

Cupping Therapy Combined with Rehabilitation for the Treatment of Radial Palsy: a Case Report

  • Benli, Ali Ramazan;Senay, Demir Yazici;Koroglu, Mustafa;Mutlu, Tansel;Erturhan, Selman;Ogun, Muhammet Nur;Sunay, Didem
    • Journal of Acupuncture Research
    • /
    • v.35 no.1
    • /
    • pp.1-3
    • /
    • 2018
  • This case report demonstrates the beneficial effects of cupping therapy (CT) in a 35-year-old man who is diagnosed with a fracture of the radial shaft due to a motorcycle accident. One year after the treatment started, pseudoarthrosis developed in the radius and an autogenous iliac bone graft was performed. However, extension dysfunction in the wrist became evident. After another 6 months of physical therapy and rehabilitation, no improvements were observed. Therefore, CT and adjunctive electrostimulation were performed, after 30 days of treatment, marked recovery of muscle function and full wrist extension were observed, as determined by electromyography and a grade 5/5 on the Medical Research Council power of wrist extension scale. The results in this case study suggest that CT in conjunction with adjunctive electrostimulation, may accelerate functional recovery from postoperative radial palsy, and provide a useful alternative treatment in this situation.

Monitoring of Fracture Occurrence During Carbon Dioxide Injection at the Meruap Oil Reservoir, Indonesia (인도네시아 머루압 유전에 이산화탄소 주입 시 균열대 생성 여부 모니터링)

  • Kim, Dowan;Byun, Joongmoo;Kim, Kiseog;Ahn, Taewoong
    • Geophysics and Geophysical Exploration
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • $CO_2$-EOR (Carbon Dioxide-Enhanced Oil Recovery), one of the enhanced oil recovery methods, helps to not only enhance the production of oil, but also store carbon dioxide in underground. However, if micro fractures occur when during the injection of $CO_2$, it is difficult to make permanent storage of $CO_2$ in reservoir and can cause contamination of groundwater and soil. Therefore, in this study, we performed microseismic monitoring to investigate the occurrence of fractures during the $CO_2$ injection at the Meruap oil reservoir, Indonesia. To pick the first arrivals of microseismic events, Improved MER (Modified Energy Ratio) method was used. After picking the first arrivals, hodogram analysis was carried out by using the data recorded at three component geophones to calculate the back azimuth of events. Finally, locations of microseismic events were decided by using the results of first arrival picking and hodogram analysis. Estimated locations showed that all microseismic events were occurred at surface and any fracture did not occur around the reservoir. Moreover, by analyzing noise characteristic, we confirmed that almost of picked first arrivals were due to the repetitive mechanical noise.

A Case of Fat Embolism Syndrome of Fat Globules Found in BAL Fluid after Recovery from Acute Respiratory Failure (급성호흡부전 호전 후 기관지폐포세척에서 지방과립구가 확인된 지방색전증후군 1예)

  • Park, Song Ree;Kim, Hyun Soo;Lee, Jae Hyung;Kim, Sang Heon;Kim, Tae Hyung;Yoon, Ho Joo;Park, Sung Soo;Shin, Dong Ho;Park, Chan Kum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.562-566
    • /
    • 2006
  • Fat embolism syndrome is a rare clinical diagnosis of dyspnea with acute respiratory failure and neurological signs caused by a traumatic long bone fracture. We report a case of fat embolism in a 22 year-old man after a traffic accident. Dyspnea and stuporous mental changes developed on the $1^{st}$ day after the external fixation operation of a left metaphyseal femur fracture. On the following day, he was transferred from a hospital to this one because of acute respiratory failure. After recovery, macrophages with fat droplets were found in the bronchoalveolar lavage fluid 1. It is important to diagnose a fat embolism as the correct cause of acute respiratory failure through the BAL in the acute state of fat embolism syndrome It is believed that clinically apparent or sometimes hidden fat embolism syndrome can be diagnosed from the BAL during the recovery state.

Verification of Numerical Technique for Hydraulic Fracturing Stimulation - by Comparison with Analytical Solutions - (수압파쇄 설계를 위한 수치해석기법의 증명 -해석식과의 비교를 중심으로 -)

  • Sim, Young-Jong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.4
    • /
    • pp.65-71
    • /
    • 2009
  • Hydraulic fracturing technology has been widely applied in the industry for the recovery of the natural resources such as gas, oil and geothermal heat from hot dry rock. During hydraulic fracturing stimulation, multiple cracks are created resulting in mechanical interaction between cracks. Such an interaction influences obtaining hydraulic fracturing key parameters (crack opening, length, and borehole net pressure). The boundary collocation method (BCM) has been proved to be very effective in considering mechanical interaction. However, for better confidence, it needs to be verified by comparison with analytical solutions such as stress intensity factors. In this paper, three cases, single fracture in remote uniaxial tension, single fracture in remote shear stress field and two arbitrary segments in an infinite plane loaded at infinity are considered. As a result, the BCM is proved to be valid technique to consider mechanical interaction between cracks and can be used to estimate the hydraulic fracturing parameters such as opening of the fracture, and so on.

  • PDF

The Efficacy of Transverse Fixation and Early Exercise in the Treatment of Fourth Metacarpal Bone Fractures

  • Moon, Suk-Ho;Kim, Hak-Soo;Jung, Sung-No;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.43 no.2
    • /
    • pp.189-196
    • /
    • 2016
  • Background Several techniques have been designed to treat fifth metacarpal fractures reported to be effective. However, these methods cannot be easily applied to the fourth metacarpal due to its central anatomical position. In this study, we sought to analyze the functional outcomes of patients who underwent transverse pinning for a fourth metacarpal bone fracture. Methods A total of 21 patients were selected and their charts were retrospectively reviewed. After fracture reduction, two transverse Kirchner wires were first inserted from the fifth metacarpal to the third metacarpal transversely at the distal part of the fractured bone, and then another two wires were inserted at the proximal part of the fractured bone. The splint was removed approximately one week postoperatively and the Kirchner wires were removed four to five weeks postoperatively. Patients started active and passive exercise one week after the operation. Pain visual analog scores, total active and passive motion, and the active and passive range of motion of the metacarpophalangeal joint and grip strength were evaluated. Results Dorsal angulation improved from a preoperative value of $44.2^{\circ}$ to a postoperative value of $5.9^{\circ}$. Six weeks after surgery, functional recovery parameters, such as range of motion and grip strength, had improved to 98% of the function of the normal side. No major complication was observed. Conclusions We suggest that the transverse pinning of fourth metacarpal bone fractures is an effective treatment option that is less invasive than other procedures, easy to perform, requires no secondary surgery, minimizes joint and soft tissue injury, and allows early mobilization.

PHILOS Plate Osteosynthesis in Metaphyseal Fractures of the Distal Humerus through an Anterolateral Approach

  • Park, Jung Ho;Kim, Jung Wook;Oh, Chi Hun;Choi, Keun Seok;Hong, Jae Young;Kim, Jae Gyoon
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.128-132
    • /
    • 2015
  • Background: We described a surgical method for osteosynthesis and reported the resultant strength after application of a PHILOS plate through the anterolateral approach for the treatment of fractures of the distal humerus. Methods: Between February 2010 and March 2012, open reduction and internal fixation operations with the PHILOS plate for treatment of fracture of the distal humerus were performed on a total of nine patients (five men, four women). The mean age was 40.8 years (range, 24-50 years), and the average follow-up period was 9.1 months (range, 6-15 months). Clinical evaluations were performed 6 months after the operation. Clinical assessment included determination of the range of motion of the elbow, the Mayo and Oxford elbow scores, and any postoperative complications. Results: Fracture union was noted in all patients, with an average period of 12.4 weeks. The average Mayo elbow and Oxford elbow scores were 87.2 (of a total of 100) and 43.3 (of a total of 48), respectively. For the postoperative range of motion of the elbow, all patients showed complete recovery to the preoperative range of motion. No other conditions, such as neurolepsis, plate breakage, or rotational deformity, were observed. Conclusions: Open reduction and internal fixation of distal humerus fractures with a PHILOS plating system via anterolateral approach can be effective. A high rate of union with good outcomes can be assumed.

Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion (Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료)

  • Kim, Jae Won;Chung, Sung Mo
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).

Management of Ipsilateral Fractures of Humerus and Forearm in Adults (성인에서 동측에 발생한 상완골과 전완골 골절의 치료)

  • Sohn Sung-Keun;Kim Byeong-Hwan;Yang Sung-Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.212-220
    • /
    • 1998
  • Concomitant ipsilateral fractures of the humerus, radius and ulna are uncommon combined injury and are also called "floating elbow". It was found that this injury was usually a result of rather severe trauma and frequently associated injuries to other organ systems. It is controversial in the treatment of the "floating elbow", but the current treatment recommendations are open reduction and internal fixation of both the humerus and the forearm fracture with early initiation of range of motion exercises. The authors reviewed thirteen cases of ipsilateral fractures of the humerus, radius and ulna treated in our clinic from January 1992 to March 1997, and average follow-up period was over 18 months(range, 12 to 36 months). The results obtained were as follows; 1. The most common cause of injury was traffic accident and most common location of fractures was mid-third in both humerus and forearm. 2. The shape of fractures was transverse or comminuted in most cases. 3. The good clinical results were obtained by open reduction and internal fixation of both the humerus and the forearm fracture with early initiation of range of motion exercises. 4. The recovery was affected by the severity of the initial trauma and method of the treatment. 5. According to the Lange and Foster method, the functional result was good in 8 cases, fair in 4 cases and poor in 1 cases.

  • PDF

Microplate Fixation without Maxillomandibular Fixation in Double Mandibular Fractures

  • Song, Seung Wook;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.53-58
    • /
    • 2014
  • Background: Maxillomandibular fixation (MMF) is usually used to treat double mandibular fractures. However, advancements in reduction and fixation techniques may allow recovery of the premorbid dental arch and occlusion without the use of MMF. We investigated whether anatomical reduction and microplate fixation without MMF could provide secure immobilization and correct occlusion in double mandibular fractures. Methods: Thirty-four patients with double mandibular fractures were treated with open reduction and internal fixation without MMF. Both fracture sites were surgically treated. For bony fixations, we used microplates with or without wire. After reduction, each fracture site was fixed at two or three points to maintain anatomical alignment of the mandible. Interdental wiring was used to reduce the fracture at the superior border and to enhance stability for 6 weeks. Mouth opening was permitted immediately. Results: No major complications were observed, including infection, plate exposure, non-union, or significant malocclusion. Five patients experienced minor complications, among whom the only one patient experienced a persistant but mild malocclusion with no need for additional management. Conclusion: This study showed that double mandibular fractures correction with two-or three-point fixation without MMF simplified the surgical procedure, increased patient comfort, and reduced complications, due to good stability and excellent adaptation.