1 |
Wong TC, Ip FK, Yeung SH. Comparison between percutaneous transverse fixation and intramedullary K-wires in treating closed fractures of the metacarpal neck of the little finger. J Hand Surg Br 2006;31:61-5.
|
2 |
Orbay JL, Touhami A. The treatment of unstable metacarpal and phalangeal shaft fractures with flexible nonlocking and locking intramedullary nails. Hand Clin 2006;22:279-86.
DOI
|
3 |
Winter M, Balaguer T, Bessiere C, et al. Surgical treatment of the boxer's fracture: transverse pinning versus intramedullary pinning. J Hand Surg Eur Vol 2007;32:709-13.
DOI
|
4 |
Westbrook AP, Davis TR, Armstrong D, et al. The clinical significance of malunion of fractures of the neck and shaft of the little finger metacarpal. J Hand Surg Eur Vol 2008;33: 732-9.
DOI
|
5 |
Galanakis I, Aligizakis A, Katonis P, et al. Treatment of closed unstable metacarpal fractures using percutaneous transverse fixation with Kirschner wires. J Trauma 2003;55:509-13.
DOI
|
6 |
Ceim U. Small fragment set manual. In: Heim U, Pfeiffer KM, Oberli K, et al., editors. Internal fixation of small fractures: technique recommended by the AO-ASIF Group. 3rd ed. New York: Springer-Verlag; 1982. p.480-4.
|
7 |
Cooney WP III, Smith DK. External fixation of the upper extremity. In: American Academy of Orthopaedic Surgeons, editor. AAOS Instructional Course Lectures. St. Louis: CV Mosby; 1987. p.445-69.
|
8 |
Riggs SA Jr, Cooney WP 3rd. External fixation of complex hand and wrist fractures. J Trauma 1983;23:332-6.
DOI
|
9 |
Gonzalez MH, Igram CM, Hall RF Jr. Flexible intramedullary nailing for metacarpal fractures. J Hand Surg Am 1995; 20:382-7.
DOI
|
10 |
Faraj AA, Davis TR. Percutaneous intramedullary fixation of metacarpal shaft fractures. J Hand Surg Br 1999;24:76-9.
DOI
|
11 |
Sohn RC, Jahng KH, Curtiss SB, et al. Comparison of metacarpal plating methods. J Hand Surg Am 2008;33:316-21.
DOI
|
12 |
Soni A, Gulati A, Bassi JL, et al. Outcome of closed ipsilateral metacarpal fractures treated with mini fragment plates and screws: a prospective study. J Orthop Traumatol 2012;13: 29-33.
DOI
|
13 |
Macey AC, Burke FD, Abbott K, et al. Outcomes of hand surgery: British Society for Surgery of the Hand. J Hand Surg Br 1995;20:841-55.
|
14 |
Gropper PT, Bowen V. Cerclage wiring of metacarpal fractures. Clin Orthop Relat Res 1984;(188):203-7.
|
15 |
Lister G. Intraosseous wiring of the digital skeleton. J Hand Surg Am 1978;3:427-35.
DOI
|
16 |
Freeland AE, Orbay JL. Extraarticular hand fractures in adults: a review of new developments. Clin Orthop Relat Res 2006; 445:133-45.
|
17 |
Waris E, Ashammakhi N, Raatikainen T, et al. Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study. J Hand Surg Am 2002;27:902-9.
DOI
|
18 |
Han SH, Rhee SY, Lee SC, et al. Percutaneous retrograde intramedullary single wire fixation for metacarpal shaft fracture of the little finger. Eur J Orthop Surg Traumatol 2013; 23:883-7.
DOI
|
19 |
Lambotte A. Contribution a la chirurgie conservatrice de la main doms les traumatismes. Arch Franco Belges Chir 1928; 31:759-61.
|
20 |
Hove LM. Fractures of the hand. Distribution and relative incidence. Scand J Plast Reconstr Surg Hand Surg 1993;27: 317-9.
DOI
|
21 |
Foucher G. "Bouquet" osteosynthesis in metacarpal neck fractures: a series of 66 patients. J Hand Surg Am 1995;20: S86-90.
DOI
|
22 |
Sletten IN, Nordsletten L, Husby T, et al. Isolated, extra-articular neck and shaft fractures of the 4th and 5th metacarpals: a comparison of transverse and bouquet (intra-medullary) pinning in 67 patients. J Hand Surg Eur Vol 2012;37: 387-95.
DOI
|
23 |
Paul AS, Kurdy N, Kay PR. Fixation of closed metacarpal shaft fractures: transverse K-wires in 22 cases. Acta Orthop Scand 1994;65:427-9.
DOI
|
24 |
Lee SK, Kim KJ, Choy WS. Modified retrograde percutaneous intramedullary multiple Kirschner wire fixation for treatment of unstable displaced metacarpal neck and shaft fractures. Eur J Orthop Surg Traumatol 2013;23:535-43.
DOI
|
25 |
Hong SJ, Lee HJ, Kim JY, et al. K-wire breakage during metalware removal due to a defective K-wire shaft. Arch Plast Surg 2013;40:655-7.
DOI
|