• 제목/요약/키워드: Four electrode

검색결과 277건 처리시간 0.028초

Electromyography 기법을 이용한 육상 크라우칭 스타트의 하체 근 동원 비교분석 (Electromyography Analysis of Muscle Activities of tower limb for Crouching Start Technique)

  • 신성휴;박기자
    • 한국운동역학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 2003
  • The purposes of this study were to analyze the muscle activities and the characteristics of muscle recruting patterns of lower limb for crouching start technique using four elite splint. The EMG technique was used to record muscle activities of both right and left sides of retus femoris, vastus medialis, biceps femoris, and gastrocnemius. Eight surface electrodes were placed on the surface of the selected muscles and one ground electrode was also attached on the back of neck(C7). One video camera was also used to record the crouching start motion to define 6 events and 5 phases for further analysis. The raw EMG data were filtered with band pass filter(10-350) to remove artifacts and then low pass filtered(4Hz) to find the linear envelope which resemble muscle tension curve. This filter EMG data were normalized to MVIC for the purpose of comparison between right and left sides muscle. The results of this study were as follows. All four subjects showed that vastus medialis muscle activity was comparatively higher than those of retus femoris, biceps femoris, gastrocnemius. And left side of muscle activity was comparatively higher than right side of muscle activity. Therefore, when the subjects starting out crouching start position, we recognized that the muscle of lower limb showed interaction effect by each muscle.

Amorphous Vanadium Titanates as a Negative Electrode for Lithium-ion Batteries

  • Lee, Jeong Beom;Chae, Oh. B.;Chae, Seulki;Ryu, Ji Heon;Oh, Seung M.
    • Journal of Electrochemical Science and Technology
    • /
    • 제7권4호
    • /
    • pp.306-315
    • /
    • 2016
  • Amorphous vanadium titanates (aVTOs) are examined for use as a negative electrode in lithium-ion batteries. These amorphous mixed oxides are synthesized in nanosized particles (<100 nm) and flocculated to form secondary particles. The $V^{5+}$ ions in aVTO are found to occupy tetrahedral sites, whereas the $Ti^{4+}$ ions show fivefold coordination. Both are uniformly dispersed at the atomic scale in the amorphous oxide matrix, which has abundant structural defects. The first reversible capacity of an aVTO electrode ($295mAhg^{-1}$) is larger than that observed for a physically mixed electrode (1:2 $aV_2O_5$ | $aTiO_2$, $245mAhg^{-1}$). The discrepancy seems to be due to the unique four-coordinated $V^{5+}$ ions in aVTO, which either are more electron-accepting or generate more structural defects that serve as $Li^+$ storage sites. Coin-type Li/aVTO cells show a large irreversible capacity in the first cycle. When they are prepared under nitrogen (aVTO-N), the population of surface hydroxyl groups is greatly reduced. These groups irreversibly produce highly resistive inorganic compounds (LiOH and $Li_2O$), leading to increased irreversible capacity and electrode resistance. As a result, the material prepared under nitrogen shows higher Coulombic efficiency and rate capability.

적층 평판형 SOFC에서 LSM 전극의 기공 제어 (Porosity Control in LSM Electrode Formation in Layered Plannar SOFC Module)

  • 이원준;여동훈;신효순;정대용
    • 한국전기전자재료학회논문지
    • /
    • 제27권12호
    • /
    • pp.866-870
    • /
    • 2014
  • In solid oxide fuel cell system, yttria-stabilized zirconia is generally adopted as the electrolyte, which has high strength and superior oxygen ion conductivity, and the air electrode and the fuel electrode are attached to this. Recently, new structure of 'layered planar SOFC module' was suggested to solve the reliability problem due to the high temperature stability of a sealing agent and a binding material. In this study to materialize the air electrode in a layered planar SOFC module, the LSM ink was coated to form homogeneous electrode in the channel after the ink preparation. As the porosity control agent, PMMA or active carbon powder was adopted with use of a commercial dispersant in ethanol. The optimal amounts of both the porosity control agents and the dispersant were determined. Four (4) vol% of the dispersant for the LSM-PMMA case and 15 vol% for LSM-carbon powder showed the lowest viscosities respectively to indicate the best dispersed states of the slurries. With PMMA and carbon powder, sintered LSM ink shows the relatively homogeneous distributions of pores and with increases of the agents, the porosities increased in both cases. From this, it can be thought that the amount of the PMMA or carbon powder could be used to control the porosity of the LSM ink.

웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구 (A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements)

  • 이강휘;이성수;김상민;이혁재;민경진;강현규;이주현;곽휘권;고윤수;이정환
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

리튬금속전극의 덴드라이트 성장 억제 방안의 연구 동향 (Review on Effective Skills to Inhibit Dendrite Growth for Stable Lithium Metal Electrode)

  • 김예랑;박지혜;황유진;정철수
    • 전기화학회지
    • /
    • 제25권2호
    • /
    • pp.51-68
    • /
    • 2022
  • 리튬금속전지는 높은 에너지 밀도를 구현시킬 수 있음에도 불구하고, 단락, 낮은 쿨롱 효율, 용량 손실, 사이클 성능 감소 등의 문제를 초래하는 덴드라이트 성장을 억제시키는 기술은 아직 학술연구 단계에 머물러 있다. 본 논문에서는 최근까지 발표된 리튬금속전극에서 덴드라이트 성장을 억제시킬 수 있는 방법을 4가지로 분류하여 분석해보았다. 즉, 리튬금속전극의 부피 팽창에 대응할 수 있는 유연한 SEI (solid electrolyte interface) 층, 덴드라이트 성장을 물리적으로 억제시킬 수 있는 SEI 지지층, 균일한 리튬 확산을 유도하여 리튬 성장을 조절하는 SHES (self-healing electrostatic shield) 메커니즘, 그리고 리튬의 균일한 전착을 유도하는 마이크로패터닝 등에 대해 연구된 사례들의 장단점을 분석하여, 리튬금속전극의 실용화 연구에 도움을 주고자 한다.

ITO Nanoparticle Film을 이용한 센서의 전극 구조가 동작 성능에 미치는 영향에 대한 연구 (Study on the Effect of the Electrode Structure of an ITO Nanoparticle Film Sensor On Operating Performance)

  • 안상수;노재하;이창한;이상태;서동민;이문진;장지호
    • 센서학회지
    • /
    • 제31권2호
    • /
    • pp.90-95
    • /
    • 2022
  • The effect of the structure of an ITO nanoparticle film sensor on its performance was studied. A printed ITO film (P-ITO film) was fabricated on a flexible polyethylene terephthalate (PET) substrate, and the contact resistance of the electrode and sensor response change were clarified according to the detection position. The contact resistance between Ag and P-ITO was observed to be -204.4 Ω using the transmission line method (TLM), confirming that a very good ohmic contact is possible. In addition, we confirmed that the contact position of the analyte had a significant influence on the response of the sensor. Based on these results, the performance of the four types of sensors was compared. Consequently, we observed that 1) optimizing the resistance of the printed film, 2) optimizing the electrode structure and analyte input position, and 3) optimizing the electrode area are very important for fabricating a metal oxide nanoparticle (MONP) sensor with optimal performance.

A Novel Approach for Controlling Process Uniformity with a Large Area VHF Source for Solar Applications

  • Tanaka, T.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.146-147
    • /
    • 2011
  • Processing a large area substrate for liquid crystal display (LCD) or solar panel applications in a capacitively coupled plasma (CCP) reactor is becoming increasingly challenging because of the size of the substrate size is no longer negligible compared to the wavelength of the applied radio frequency (RF) power. The situation is even worse when the driving frequency is increased to the Very High Frequency (VHF) range. When the substrate size is still smaller than 1/8 of the wavelength, one can obtain reasonably uniform process results by utilizing with methods such as tailoring the precursor gas distribution by adjustingthrough shower head hole distribution or hole size modification, locally adjusting the distance between the substrate and the electrode, and shaping shower head holes to modulate the hollow cathode effect modifying theand plasma density distribution by shaping shower head holes to adjust the follow cathode effect. At higher frequencies, such as 40 MHz for Gen 8.5 (2.2 m${\times}$2.6 m substrate), these methods are not effective, because the substrate is large enough that first node of the standing wave appears within the substrate. In such a case, the plasma discharge cannot be sustained at the node and results in an extremely non-uniform process. At Applied Materials, we have studied several methods of modifying the standing wave pattern to adjusting improve process non-uniformity for a Gen 8.5 size CCP reactor operating in the VHF range. First, we used magnetic materials (ferrite) to modify wave propagation. We placed ferrite blocks along two opposing edges of the powered electrode. This changes the boundary condition for electro-magnetic waves, and as a result, the standing wave pattern is significantly stretched towards the ferrite lined edges. In conjunction with a phase modulation technique, we have seen improvement in process uniformity. Another method involves feeding 40 MHz from four feed points near the four corners of the electrode. The phase between each feed points are dynamically adjusted to modify the resulting interference pattern, which in turn modulate the plasma distribution in time and affect the process uniformity. We achieved process uniformity of <20% with this method. A third method involves using two frequencies. In this case 40 MHz is used in a supplementary manner to improve the performance of 13 MHz process. Even at 13 MHz, the RF electric field falls off around the corners and edges on a Gen 8.5 substrate. Although, the conventional methods mentioned above improve the uniformity, they have limitations, and they cannot compensate especially as the applied power is increased, which causes the wavelength becomes shorter. 40 MHz is used to overcome such limitations. 13 MHz is applied at the center, and 40 MHz at the four corners. By modulating the interference between the signals from the four feed points, we found that 40 MHz power is preferentially channeled towards the edges and corners. We will discuss an innovative method of controlling 40 MHz to achieve this effect.

  • PDF

Simulations of Capacitively Coupled Plasmas Between Unequal-sized Powered and Grounded Electrodes Using One- and Two-dimensional Fluid Models

  • So, Soon-Youl
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.220-229
    • /
    • 2004
  • We have examined a technique of one-dimensional (1D) fluid modeling for radio-frequency Ar capacitively coupled plasmas (CCP) between unequal-sized powered and grounded electrodes. In order to simulate a practical CCP reactor configuration with a grounded side wall by the 1D model, it has been assumed that the discharge space has a conic frustum shape; the grounded electrode is larger than the powered one and the discharge space expands with the distance from the powered electrode. In this paper, we focus on how much a 1D model can approximate a 2D model and evaluate their comparisons. The plasma density calculated by the 1D model has been compared with that by a two-dimensional (2D) fluid model, and a qualitative agreement between them has been obtained. In addition, 1D and 2D calculation results for another reactor configuration with equal-sized electrodes have also been presented together for comparison. In the discussion, four CCP models, which are 1D and 2D models with symmetric and asymmetric geometries, are compared with each other and the DC self-bias voltage has been focused on as a characteristic property that reflects the unequal electrode surface areas. Reactor configuration and experimental parameters, which the self-bias depends on, have been investigated to develop the ID modeling for reactor geometry with unequal-sized electrodes.

직접메탄올 연료전지의 농도 및 온도변화에 따른 실험적 검증 (Experimental Validation of a Direct Methanol Fuel Cells(DMFCs) model with a Operating Temperatures and Methanol Feed Concentrations)

  • 강경문;고요한;이기용;주현철
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.125.2-125.2
    • /
    • 2010
  • In this paper, both theoretical and experimental investigations have been performed to examine the effects of key operating parameters on the cell performance of a DMFCs (i.e., methanol feed concentration and operating temperature). For experiment, the membrane electrode assemblies (MEAs) were prepared using a conventional MEA fabrication method based on a catalyst coated electrode (CCE) and tested under various cell temperatures and methanol feed concentrations. The polarization curve measurements were conducted using in-house-made $25cm^2$ MEAs. The voltage-current density data were collected under three different cell temperatures ($50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$) and four different methanol feed concentrations (1 M, 2 M, 3 M, and 4 M). The experimental data indicate that the measured I-V curves are significantly altered, depending on these conditions. On the other hand, previously developed one-dimensional, two-phase DMFC model is simulated under the same operating conditions used in the experiments. The model predictions compare well with the experimental data over a wide range of these operating conditions, which demonstrates the validity and accuracy of the present DMFC model. Furthermore, both simulation and experimental results exhibit the strong influences of methanol and water crossover rates through the membrane on DMFC performance and I-V curve characteristics.

  • PDF

The research of dependency between trigger condition and trigger geometry for triggered vacuum switch

  • 박웅화;김무상;손윤규;이병준
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.228.2-228.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) discharges high current through two processes. In the first process, an igniting plasma is generated at a trigger system, and the next process that a main discharge is taken place sequentially at a six-gap rod electrode within a few microsecond. In general, a triggered voltage producing the igniting plasma is increased. However, after several hundred shots, it goes down and stable, in our experiment the trigger voltage is about 5 kV after 250 shots. This triggered characteristics comes from the ceramic insulator which is covered by an electrode material, therefore we have focused on the first igniting plasma process. The igniting plasma has been generated at the surface of a ceramic insulator under a strong electric field. The electric field can be increased through modifying geometries of trigger components which compose of a trigger pin, a ceramic insulator and an enclosed holder. We fabricated not only two types of trigger pin which are a plane head and an umbrella head type, but two different holders which are a concave and a convex type. In this paper the result that the dependency of geometries for these four combined types is included, but the study of the ceramic insulator is not. The research of the ceramic insulator will be announced in the other paper.

  • PDF