• 제목/요약/키워드: Four electrode

검색결과 275건 처리시간 0.023초

Properties of Carbon Pastes Prepared with Mixing Ratios of Nano Carbon and Graphite Flakes

  • Kim, Kwangbae;Song, Ohsung
    • 한국재료학회지
    • /
    • 제28권11호
    • /
    • pp.615-619
    • /
    • 2018
  • To produce carbon electrodes for use in perovskite solar cells, electrode samples are prepared by mixing various weight ratios of 35 nm nano carbon(NC) and $1{\mu}m$ graphite flakes(GF), GF/(NC+GF) = 0, 0.5, 0.7, and 1, in chlorobenzene(CB) solvent with a $ZrO_2$ binder. The carbon electrodes are fabricated as glass/FTO/carbon electrode devices for microstructure characterization using transmission electron microscopy, optical microscopy, and a field emission scanning electron microscopy. The electrical characterization is performed with a four-point probe and a multi tester. The microstructure characterization shows that an electrode with excellent attachment to the substrate and no surface cracks at weight ratios above 0.5. The electrical characterization results show that the sheet resistance is <$70{\Omega}/sq$ and the interface resistance is <$70{\Omega}$ at weight ratios of 0.5 and 0.7. Therefore, a carbon paste electrode with microstructure and electrical properties similar to those of commercial carbon electrodes is proposed with an appropriate mixing ratio of NC and GF containing a CB solvent and $ZrO_2$.

단일벽 탄소 나노튜브의 엑츄에이터 응용 (Actuaots based on Single Walled Carbon Nanotube)

  • 오영석;조승범;최재붕;김영진;백승현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1387-1390
    • /
    • 2006
  • Several actuation mechanism for carton nanotubes has teen reported recently, including actuation by double-layer charge injection and ac voltages applyied to multiple electrodes. Carbon nanotube actuator based on double layer charge injection work well in electrolyte at low voltage. AC dielectrophoresis based on four electrode geometry demonstrated carton nanotubes in solution phase can be oriently manipulated by dielectrophoresis. From this point of view, and in regard to their performance, bucky paper actuator may alternate natural muscle. also, applied AC signal with appropriate magnitude and frequency together with four electrode arrangement has potential to realize nanotube electrokinetics.

  • PDF

압전 PMN-PZT 단결정의 유전 및 압전 특성에 미치는 전극 종류의 영향 (Effect of the Electrode Type on the Dielectric and Piezoelectric Properties of Piezoelectric PMN-PZT Single Crystals)

  • 이종엽;오현택;최균;이호용
    • 한국세라믹학회지
    • /
    • 제52권1호
    • /
    • pp.77-82
    • /
    • 2015
  • The effect of the electrode type on the dielectric and piezoelectric properties of $Pb(Mg_{1/3}Nb_{2/3})O_3-PbZrO_3-PbTiO_3$ (PMN-PZT) single crystals was investigated in an effort to improve their properties for various piezoelectric applications. First, three different types of PMN-PZT single crystals [PMN-PZT-A (piezoelectrically soft type; dielectric constant ~ 10,000), PMN-PZT-B (piezoelectrically soft type; phase-transition temperature between the rhombohedral and tetragonal phases ($T_{RT}$) ~ $145^{\circ}C$), PMN-PZT-C (piezoelectrically hard type; high mechanical quality factor ($Q_m$) ~ 1,000)] were fabricated using the solid-state single crystal growth (SSCG) method. Then, four different types of electrodes [sputtered Au, sputtered Cr/Au, sputtered Ti/Au, and fired Ag] were formed on the single crystals, and their dielectric and piezoelectric properties were measured. The single crystals with a sputtered Ti/Au electrode showed the highest dielectric and piezoelectric constants but the lowest coercive electric field ($E_C$). The single crystals with a fired Ag electrode showed the lowest dielectric and piezoelectric constants but the highest coercive electric field ($E_C$). This dependence on the type of electrode was most significant in the piezoelectrically hard PMN-PZT-C single crystals. However, the effects of the electrode type on the phase transition temperatures ($T_C$, $T_{RT}$) and dielectric loss were negligible. These results clearly demonstrate that it is important to select an appropriate electrode so as to maximize the dielectric and piezoelectric properties of single crystals in each type of piezoelectric application.

Pace-maker 사용 4예 경험 (Clinical Use of the Pace-maker in four cases)

  • 이성구
    • Journal of Chest Surgery
    • /
    • 제13권3호
    • /
    • pp.219-228
    • /
    • 1980
  • The heart block and bradyarrhythmia with or without Stokes-Adams attacks are serious, usually terminal events and the immediate mortality is very high. Stimulation with an artificial pacemaker is now an accepted form of treatment in cases of Stokes-Adams syndrome in which medication in unable to produce any lasting improvement. Permanent pacemaker therapy is indicated in these circumstances. The purpose of this report is to describe the successful use of pacemaker in 3 cases of Stokes-Adams syndromes and a case of sinoatrial block with bradyarrhythmia at the Department of Thoracic and Cardiovascular Surgery, Kyungpook National University School of Medicine. Electrode catheter was passed through the right external jugular vein and attached to the endocardial surface of the right ventricle. In case 1, fixed type generator was used at first and for the case 2, 3, 4, and case 1 at second, demand type generators were used. The bipolar electrode catheters were used for the three cases and unipolar electrode catheter for case 4. The results of immediate and late period were satisfactory.

  • PDF

임피던스 방식의 동작분석을 위한 최적전극 선정 (Optimal Electrode Displacement for Motion Analysis using Bio-impedance)

  • 송철규;변용훈;윤대영;이명권;김거식;송창훈;김경섭;김수찬;김덕원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2887-2890
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh, knee, and foot, and two potential electrodes are applied to the lateral, medial, and posterior position of lower leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for ankle, knee and hipjoint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements -0.87, 0.957 and 0.80. respectively. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed possibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

  • PDF

Identification of Reaction Mechanism to Produce High Quality Weld During Submerged Arc Welding

  • Kim, Jeong-Han;Kang, Kyong-Sik
    • 품질경영학회지
    • /
    • 제21권2호
    • /
    • pp.242-253
    • /
    • 1993
  • The interpretation of the reaction mechanism is significant to produce the high quality welds and understand the welding processes. This investigation is important for the design of welding consumables and the selection of welding process parameters to develop the high quality welds. The objective of this study is to investigate the effect of electrochemical reactions on the transfer of alloy elements between slag and weld metal during submerged arc welding During submerged arc welding weld metal composition is shown to be controlled by two reaction mechanisms in four reaction zones. The responsible reaction mechanisms are thermochemical and electrochemical reactions. The possible reaction sites are the melted electrode tip, the detached droplet, the hot weld pool immediately below the moving electrode, and the cooling and solidifying weld pool behind the moving electrode. The possible reactions in submerged arc welding at different zones of the process is schematically shown in Figure 1.

  • PDF

A Study on the Development of Underwater Wet Welding Electrodes

  • Kim, Min-Nam
    • 한국해양공학회지
    • /
    • 제17권4호
    • /
    • pp.52-58
    • /
    • 2003
  • Underwater wet arc welds were experimentally performed on the KR-RA steel plate as base metal by using four different types of flux coated electrodes: KT33, UWEE, UWCS, and TN20, UWEE, the individually designed flux coated underwater electrode, had good operability when compared with other domestic terrestrial electrodes, and imported goods. The hardness value and the portion of martensite of HAZ were increased, by using a rapid cooling rate, Mechanical properties were also examined experimentally with a multi-pass butt-welding specimen test. The individually designed flux coated electrode UWEE could be used in practice for underwater wet welds.

A Study on the Development of Underwater Wet Welding Electrodes

  • Kim, Min-Nam
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제6권1호
    • /
    • pp.75-81
    • /
    • 2003
  • Underwater wet arc welds were experimentally performed on the KR-RA steel plate as base metal by using four different types of flux coated electrodes: KT33, UWEE, UWCS, and TN20. UWEE, the individually designed flux coated underwater electrode, had good operability when compared with other domestic terrestrial electrodes, and imported goods. The hardness value and the portion of martensite of HAZ were increased, by using a rapid cooling rate, Mechanical properties were also examined experimentally with a multi-pass butt-welding specimen test. The individually designed flux coated electrode UWEE could be used in practice for underwater wet welds.

  • PDF

부분 방전에 의한 실리콘 케이블의 열화 특성에 관한 연구 (A Study on Degradation Properties of Silicone Cable due to Partial Discharge)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.34-39
    • /
    • 2015
  • In this study, the characteristics of partial discharge was measured for the four core silicone cable (0.6/1.0 kV, $1.0SQ{\times}4C$) with insulated part of 15 cm and conductor of 1cm. The following results have been confirmed as a result of this study. When the first line of cable is connected to the positive electrode and the second, third line of cable is connected to the negative electrode, it found that the inception voltage and extinction voltage decreased with increasing the line of negative electrode, and the partial discharge charge quantity(Q) increases, while the number of discharge occurrence has decreased. The inception voltage and extinction voltage of partial discharge has decreased with increasing the degradation rate in the 33%, 67%, 100%. Also, it confirmed that the partial discharge charge quantity(Q) and the number of discharge occurrence has decreased.