• Title/Summary/Keyword: Foundation inspection

Search Result 119, Processing Time 0.023 seconds

An Optimization of a Walkway Block Structure for Rainwater Harvesting (빗물저장 및 활용을 위한 보도블럭구조의 최적화)

  • Cho, Taejun;Son, Byung-Jik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.40-47
    • /
    • 2018
  • Porous walkway blocks are constructed for the purpose already, but reserved water is easily consumed due to the bigger permeability than necessary. Furthermore, porous structure reduces the strength of blocks, which resulting cracking and settlements in walkways. In this study, we suggested a solution for given problems by determination for the location of minimum principal stress in walkway blocks against moving foot loads in order to design and verifying the determined location of minimum principal stress. An optimum design with a verification example for determined location of minimum principal stress have been presented in a two dimensional Block member on elastic foundation for pedestrian walkway for reserving water inside. The minimum value for sum of shear forces is found when ${\times}1$ is 58.58 mm(30% of total span, 200mm), while the minimum deformation is located at ${\times}2=80mm$(70% of total span, 200 mm). In a modified model, When moving boundary condition(walkway foot loads) is located at ${\times}1$(=0 mm), the location of minimum principal stresses is found at 168 mm( 84% of span, 200 mm), in which the stress concentration due to the foot load is modeled as two layers of distributed loads(reactions of foundation modeled as springs). Consequently, zero deformed reservoirs for rainwater on the neutral axis (${\times}2=167mm$) has been determined in the modified model with three dimensional FEM analysis verifications.

Pile-cap Connection Behavior between Hollow-Head Precast Reinforced Concrete Pile and Foundation (프리캐스트 철근콘크리트 중공 말뚝과 기초 접합부 반복가력 거동)

  • Bang, Jin-Wook;Jo, Young-Jae;Ahn, Kyung-Chul;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.71-77
    • /
    • 2019
  • Recently, most of the pile foundations have been applied as a method to transfer the heavy load of the structure to the ground with high bearing capacity. In this study, the pile-cap behavior between foundation and hollow-head precast reinforced concrete(HPC) pile reinforced with longitudinal rebar and filling concrete was experimentally evaluated depending on the cyclic load and reinforcement ratio. As the drift ratio increases, it was found that the cracks pattern and fracture behavior of two types of pile-cap specimens according to the reinforcement ratio were evaluated to be similar. As the reinforcement ratio increases by 1.77 times, the BS-H25 specimen increases the maximum load by 1.47 times compared to the BS-H19 specimen. However, the ductility ratio of positive and negative was decreased by 76% and 70% respectively. After the yielding of the pile-cap reinforcing rebars, the positive and negative stiffness of the all specimens were decreased by a range from 66% to 71% and a range from 54% to 57% respectively, and the average stiffness of BS-H25 specimen is 13% higher than that of BS-H19 specimen. The cumulative dissipated energy capacity of BS-H19 and BS-H25 specimen under ultimate load state is 5.5 times and 6.6 times higher than that of service load state.

A Study on the Behavior of Concrete floors with Over-break in Railroad Tunnel (여굴깊이에 따른 철도터널 바닥 콘크리트의 거동에 관한 연구)

  • Yang, Joo-Kyoung;Kim, Hyo-Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.101-107
    • /
    • 2017
  • Over-break, which is excavated larger than planned line at tunnel excavation, is inevitable due to the nature of blasting. But regarding the bottom of the foundation, most of the domestic ordering organizations pay only 10 cm thick filled concrete when pouring concrete due to over-break. In accordance, the construction cost will increase greatly if all the depths of the designed over-break are filled only with concrete. When tunnel excavation occurs, concrete filling of 18 MPa(T = 100 mm) and 150 mm~237 mm auxiliary concrete layer and 240 mm concrete track(TCL) are applied to the upper part. The concrete is installed in an excessive amount of about 600 mm between the lower part of the rail and the tunnel rock bed. Therefore, in this study, it is necessary to analyze the concrete crack structure according to the depth of the existing tunnel and the modified tunnel section, and to evaluate the adequacy of the required thickness of the tunnel floor concrete for securing the crack stability of the concrete.

Spectator Evaluation Process for Animation : Focusing on Netizen Grades and Review Bulletin Board (애니메이션 속성이 관람 후 평가에 미치는 영향 : 네티즌 평점.리뷰 게시판을 중심으로)

  • So, Yo-Hwan
    • Cartoon and Animation Studies
    • /
    • s.13
    • /
    • pp.115-131
    • /
    • 2008
  • This research analyzed whether some loading persons influence at process that spectator sees and evaluates animation for theater. Research target did netizen grades and review bulletin board and mentioned estimation contents after inspection and sorted virtue research by attribute practical attribute and emotional attribute to foundation to measure assessment of consumption form. As research result, that story, character, directing, background art, background music, actor dubbing, special effect, publisher etc. are review variableness in practical attribute by appeared emotional enemy in attribute review variableness of fun, emotion, satisfaction, fascinating, fantasy, excitement etc. be appear. Specialty, showed positive correlation that do individually is between two attributes, and predicted that relation between two attributes Influences in animation estimation after inspection. Conclusively, animation spectator emotional enemy about specific practical Intensive experience analysis that evaluate whole work by intermediation process possible.

  • PDF

A Study on the Counterplan for the Reinforcement of Port State Control - Primarily on the Korean Shipping Companies - (항만국통제 강화에 따른 우리나라 해운기업의 대응방안에 관한 연구)

  • Choi. U.;Shin, H.W.;Pyo, H.Y.;Choi, Y.R.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.41-58
    • /
    • 2003
  • A recent trend of global shipping industry adopting Port State Control (PSC) system is recognized as a proficient mechanism in preventing costal traffic accident and protecting marine environment. Disadvantages of Korean shipping companies in PSC inspection are unavoidable as Tokyo MOU imposed priority listed flag to Korea. Having stated above, appropriate research and prompt preparation in compliance with current PSC requirements for the Korean shipping companies have become an immediate need. The objectives of this study are : First, to review in understanding of PSC in overall and foundation of enforcement. Second. to study interaction of international treaties regarding PSC. Third, to compare practical compliance among the countries and to open up a case study on Korean shipping companies in adopting PSC. Last, to suggest direction to the Korean shipping companies the most proficient way in compliance with the current Tokyo MOU requirement. Korean flagged vessels have become prioritized target in PSC inspection as Tokyo MOU imposed priority listed flag to Korea due to high detention rate of its fleet. Disadvantage of a priority listed flag is a burden in its proficient fleet operation. This study suggests solutions to the disadvantages as below. : 1) Change shore management system, and provide continuous & quality education to crew members 2) Form a network in sharing PSC information among the Korean shipping companies 3) Form a centralized function in which government, Korean Shipping register and shipowners can treat problems in a prompt manner.

  • PDF

Experimental Evaluation of Reserve Capacities for Connection Details between Steel Pipe Pile and Concrete Footing of Type-B (Type-B방식의 강관말뚝과 확대기초 연결부 상세에 따른 보유내력의 실험적 평가)

  • Han, Sang-Hoon;Hong, Ki-Nam;Kwon, Yong-Kil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.1
    • /
    • pp.183-192
    • /
    • 2008
  • Generally, application of steel pipe pile as deep foundation member needs special requirement for the connection method between steel pipe pile and concrete footing. Even though two types of connection method are suggested in the korea highway bridge code, type-B method is prevalent. In this study, vertical, lateral, and tension loading test are done for two types of type B connection to review stress concentration, formation and behavior of imaginary RC column in the footing. Welding type and hook type as the connection method are considered in this study. Test results show that welding type have the more reserve capacity than hook type and the specimens connected by the welding type behave as the imaginary RC column in the footing. However, the specimens connected by the hook type did not behave as the imaginary RC column in the footing but behave as the hinge.

Pile-cap Connection Behavior Dependent on the Connecting Method between PHC pile and Footing (PHC말뚝과 확대기초 연결방법에 따른 접합부 거동)

  • Bang, Jin-Wook;Oh, Sang-Jin;Lee, Seung-Soo;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.25-32
    • /
    • 2016
  • The pile-cap connection part which transfers foundation loads through pile body is critical element regarding flexural and shear force because the change of area, stress, and stiffness occurs in the this region suddenly. The purpose of this study is to investigate the structural behavior of pile-cap connection dependent on fabrication methods using conventional PHC pile and composite PHC pile. A series of test under cyclic lateral load was performed and the connection behavior was discussed. From the test results, it was found that the initial rotational stiffness of pile-cap connection was affected by the length of pile-head inserted in footing and the location of longitudinal reinforcing bars. The types of pile and location of longitudinal reinforcing bars governed the behavior of pile-cap connection regarding load-carrying capacity, ductility, and energy dissipation.

Seismic Performance Evaluation of Nonseismic Neighborhood Living Facilities Considering Deterioration (비내진 근린생활시설의 노후도를 고려한 내진성능평가)

  • Lee, Young Cheon;Jeoung, Chae Myeoung;Lee, Eun Jin;Kim, Myung Hoon;Choi, Ki Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • In this study, seismic performance was evaluated considering the deterioration level for the low-rise and moderate buildings with non-seismic details which are most common in Korea. Evaluation results showed that the deterioration condition is relatively good even after 24 years of construction but the seismic performance did not satisfy the protection index in the first and second evaluation. In case of the third evaluation, the goal performance was satisfied based on the interstory drift ratio but reinforcement is found to be necessary. Seismic performance was evaluated after the target buildings were reinforced in the walls, bracing, and damper. Results showed the interstory drift ratio drastically reduced regardless of reinforcement methods and satisfied the level of immediate occupancy. In case of wall reinforcement, however, base shear increased more than double which requires review on the existing foundation.

Effect of Surface Preparation and Curing Condition on the Interfacial Bond Strength between Ultra High Performance Concrete and Normal Strength Concrete (표면처리 및 양생 조건이 초고성능 콘크리트-보통 콘크리트 계면 부착강도에 미치는 영향)

  • Kang, Sung-Hoon;Hong, Sung-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.149-160
    • /
    • 2015
  • This study reports the interfacial bond strength between Ultra High Performance Concrete (UHPC) and Normal Strength Concrete (NSC). While previous studies have focused on the interfacial strength between NSC substrate and UHPC overlay, this study use precast UHPC for enhanced constructability and replacement of formwork. The factors affecting the interface strength are comprehensively reviewed. It can be classified into: interface shape, degree of hardening and moisture condition of UHPC before combining with NSC, and curing condition of composite materials. Conducted experiments verify the effects of each factor on the interface strength and, accordingly show different failure modes. In particular, a new failure mode of the failure of a part of UHPC was firstly found in the case of sample with rough interface between UHPC and NSC. The other factors of the degree of hardening and the moisture and curing conditions of UHPC were discussed. This research will provide a valuable foundation to utilize the UHPC as a composite material.

Techniques for Characterizing Surface Deterioration of Epoxy Exposed to Ozone Damage (오존에 노출된 에폭시 코팅재의 표면 열화특성 평가기술)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.167-177
    • /
    • 2014
  • New technologies for water purification are continuously emerging to address global water quality problems, and one such technology involves advanced hermetic water purification facilities made by concrete that utilize ozone treatment processes. Better knowledge about surface deterioration of epoxy coating exposed to ozone treatment is needed as a foundation for development of improved methods and materials in the future. This study utilized atomic force microscopy (AFM), nanoindentation methods, and existing indirect methods such as visual observation, changes in mass, surface observation and chrominance analysis, to evaluate epoxy water-resistance and anti-corrosiveness. This study considered six different epoxy formulations to assess typical degradation characteristics of epoxy surfaces with regard to water-resistance/anti-corrosiveness. AFM and nanoindentation techniques emerged as promising direct methods with potential to provide quantitative measures of surface quality that are improvements upon existing indirect methods. The experiments also confirmed that some of the epoxy-coatings were severely iMPacted by ozone exposure, and thus the results demonstrate that concern about such deterioration is justified.