• 제목/요약/키워드: Fouling surface

검색결과 279건 처리시간 0.028초

표면개질된 폴리설폰 막에 대한 오일에멀젼의 수투와 플럭스 (Water Permeation Flux of Oil-Emulsion through Surface-Modified Polysulfone Membrane)

  • 송근호;김강희;조성헌;이광래
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.187-191
    • /
    • 2003
  • A hollow-fiber type polysulfone UF membrane was surface-coated with hydroxyethylmethacrylate (HEMA). The effect of various coating parameters on permeation flux, such as concentration ratio of AIBN/HEMA, solvent(water or methanol), and UV irradiation time, was investigated. The water permeation flux of oil-emulsion increased with concentration ratio of AIBN/HEMA, and increased with UV irradiation time. The flux of the membrane coated in solution using methanol as a solvent was greater than that of the membrane coated in solution using water as a solvent. The flux of both the coated and the uncoated membrane declined with the operation. The flux decline means that the membrane fouling by oil-emulsion occurs. However, the fouling of the coated membrane was much less than that of the uncoated membrane.

  • PDF

IGCC 합성가스 냉각 시스템의 열전달 특성 연구 (Numerical Analysis on the Heat Transfer Characteristics of Syngas Cooling System of an IGCC Process)

  • 오준호;예인수;박상빈;류창국;박성구
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2013년도 제46회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.65-68
    • /
    • 2013
  • In a syngas cooling system of coal gasification process, fly slag carried by syngas deposit on the surface of heat exchanger. The deposited materials form a fouling layer with several millimeters thickness, disturbing heat transfer between steam and syngas. This study investigates flow and heat transfer characteristics of syngas in helical coil heat exchanger using computational fluid dynamics under clean and fouled surface condition. Process model were also designed and its results are in good agreement with CFD results.

  • PDF

정유량 한외여과에서 자연대류 불안정성의 막오염 감소 및 임계 플럭스 증가 효과 (Effect of Natural Convection Instability on Reduction of Fouling and Increasing of Critical Flux in Constant-flow Ultrafiltration)

  • 장아름;남상원;염경호
    • 멤브레인
    • /
    • 제22권5호
    • /
    • pp.332-341
    • /
    • 2012
  • 실리카 콜로이드 용액의 정유량 한외여과에서 중력 방향에 대한 막모듈의 위치(경사각) 변화에 따라 발생되는 자연대류 불안정 흐름의 막오염 저감효과를 차압의 변화 정도를 측정하여 규명하였다. 막표면에 케이크 층을 형성함으로서 막오염을 발생시키는 나노 사이즈의 실리카 입자(평균 크기 = 7, 12, 22, 50 nm 및 78 nm)가 함유된 5가지 종류의 콜로이드 용액을 사용하여 중력 방향에 대한 막모듈의 위치(경사각 = $0^{\circ}{\sim}180^{\circ}$)에 따른 차압의 변화를 교반이 없는 dead-end 정유량 한외여과 실험을 통해 측정하였다. 상대적으로 크기가 작은 실리카 입자(7, 12 nm 및 22 nm)가 함유된 콜로이드 용액의 정유량 한외여과에서 막모듈 경사각을 $30^{\circ}$ 이상으로 유지하면 막모듈에 자연대류 불안정 흐름이 발생되어 막오염 형성을 크게 억제시켜 차압의 증가가 거의 나타나지 않았다. 이 자연대류 불안정 흐름의 발생은 막표면에 형성된 실리카 케이크층의 벌크용액으로의 역이동(back transport)을 유발시킴으로서 차압의 증가를 억제시키는 막성능 개선 효과를 나타내었다. 그러나 상대적으로 크기가 큰 실리카 입자(50 및 78 nm)가 함유된 콜로이드 용액의 정유량 한외여과에서는 자연대류 불안정 흐름 발생의 효과가 거의 없었다. 임계 플럭스 측정 결과 실리카 입자의 크기가 작을수록 그리고 막모듈 경사각이 클수록 막모듈에의 자연대류 불안정 흐름의 발생 강도가 커져 막오염 형성이 억제되었으며, 이로 인해 임계 플럭스가 증가하였다.

PES 여과막의 물리적 막오염 개선을 위한 기공 구조 개선 연구 (Improving Physical Fouling Tolerance of PES Filtration Membranes by Using Double-layer Casting Methods)

  • 김창헌;유영민;김인철;남승은;이정현;백영빈;조영훈
    • 멤브레인
    • /
    • 제33권4호
    • /
    • pp.191-200
    • /
    • 2023
  • Polyethersulfone (PES)은 친수성과 상분리법의 용이성 덕분에 수처리 및 정제 분야에서 정밀여과 및 한외여과막 소재로 일반적으로 사용된다. 그러나, 비용매 유도 상분리법으로 제조된 PES 분리막, 특히 지지체가 없는 여과막의 경우 도프의 조성과 기재의 특성에 따라 여과막 하부에 낮은 기공도를 갖는 치밀층이 형성되기 쉽고, 이러한 치밀층으로 인해 수투과 저항이 증가하고 오염물질의 쌓임에 의한 막오염이 일어난다. 본 연구에서는 PES 여과막 제조 시 상전이 과정의 수축으로 인해 분리막 하부에 물이 침투하여 치밀층을 형성, 심각한 막오염을 유발할 수 있음을 확인하였다. 동일한 선택층을 갖는 PES 여과막을 단일층 및 이중층 캐스팅법으로 각각 제조하여 하부 치밀층이 여과막의 투과성능 및 막오염에 미치는 영향을 파악하고자 하였다. 하부 치밀층이 없는 이중층 캐스팅된 여과막은 기존 여과막 대비 높은 투과성능 및 막오염에 대한 저항성을 보였으며, 이를 통해 다공성 여과막의 내오염성을 향상시키기 위한 표면 기공도 및 기공 구조 등 물리적 구조의 최적화가 중요함을 확인하였다.

UF 막 여과 공정의 효과적인 전처리 공정으로 분류교반고액분리조(噴流攪拌固液分離槽) (Jet Mixed Separator: JMS) 도입 효과에 관한 연구 (A Study on Effect of Jet Mixed Separator Combination for Pre-treatment of Ultrafiltration Membrane Filtration Process)

  • 이상협;장낙용;渡辺義公
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.38-46
    • /
    • 2005
  • In this research, we tried to combine the coagulation/sedimentation process as pre-treatment with UF membrane filtration to reduce the membrane fouling and to improve the permeate water quality. We used the Jet Mixed Separator (JMS) as coagulation/sedimentation process. We observed that the HPC and E.Coli can't be removed through the direct UF memebrane filtation of surface water. The removal efficiency of dissolved organic substances, indicated by E260 and DOC, was 40% and 15%, respectively. However, the removal efficiency of it increased two time as a result of combination of JMS process as coagulation/sedimentation pre-treatment. This was resulted from the formation of high molecular humic micro-floc through JMS process. The accumulation amount of irreversible cake layer which was not removed by backwashing was less than direct UF membrane filtration of surface water. Moreover, the loading rate of fouling induced substances, such as humic substances and suspended substances, on membrane surface decreased drastically through JMS process. As a result, the accumulation amount of irreversible cake on membrane surface was decreased.

Effects of Surface Modification of the Membrane in the Ultrafiltration of Waste Water

  • Cho Dong Lyun;Kim Sung-Hyun;Huh Yang Il;Kim Doman;Cho Sung Yong;Kim Byung-Hoon
    • Macromolecular Research
    • /
    • 제12권6호
    • /
    • pp.553-558
    • /
    • 2004
  • An ultrafiltration membrane (polyethersulfone, PM 10) was surface-modified by treating it with low-tem­perature plasmas of oxygen, acrylic acid (AA), acetylene, diaminocyolohexane (DACH), and hexamethyldisiloxane (HMDSO). The effects that these modifications have on the filtration efficiency of a membrane in waste water treat­ment were investigated. The oxygen, AA, and DACH plasma-treated membranes became more hydrophilic. The water contact angles ranged from < $10^{\circ}\;to\;55^{\circ}$ depending on the type of plasma and the treatment conditions. The oxygen plasma-treated membranes displayed a higher initial flux $(312-429\%),$ but lower rejection $(6-91\%),$ than did an untreated membrane. The AA plasma-treated membranes displayed lower or higher initial flux $(42-156\%),$ depending upon the treatment conditions, but higher rejection $(224-295\%)$ in all cases. The DACH plasma-treated membranes displayed lower initial flux. All of them, especially the AA plasma-treated membrane, displayed improved fouling resistance with either a slower or no flux decline. Acetylene and HMDSO plasma-treated membranes became more hydrophobic and displayed both lower initial flux and lower fouling resistance.

Modification of ultrafiltration membranes with carbon nanotube buckypaper for fouling alleviation

  • Guo, Jin;Liu, Jian-Hong;Wang, Li-Ying;Liu, Hong
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.1-13
    • /
    • 2015
  • The modification of ultrafiltration membranes with carbon nanotube (CNT) buckypaper on fouling control was investigated. Two types of commercially available flat-sheet membranes were used: PS35 and PES900C/D (PES) (the PS35 membranes were hydrophilic with a molecular weight cutoff of 20 kDa, and the PES membranes were hydrophobic with a molecular weight cutoff of 20 kDa). The CNT buckypaper modified ultrafiltration membranes were prepared by filtering a CNT suspension through the flat-sheet membrane in a dead-end ultrafiltration unit. After modification, the pure water flux of PES was significantly increased, while the pure water flux of PS35 was decreased. The properties of the CNT modified membranes were also investigated. Considering the antifouling properties, pure water flux of the modified membrane, and the stability of CNT buckypaper layer on the membrane surface, ethanol solution with a concentration of 50 wt.%, multi-walled carbon nanotubes (MWCNTs) with a larger diameter (30-50 nm), and the CNT loading with $7.5g/m^2$ was selected. The CNT buckypaper on the surface of ultrafiltration membranes can trap the pollutants in sewage effluent and prevent them reaching the surface of virgin membranes. Water quality analysis showed that the effluent quality of the modified membrane was obviously improved. The removal efficiency of humic acid and protein-like matters by the modified membrane was significant. These results indicate the potential application of the CNT buckypaper layer modified membranes in the field of wastewater reclaim.

원수의 수질화학과 HA의 물리화학적 특성이 막 오염에 미치는 영향 (Effects of Surface Water Chemistry and Physicochemical Characteristics of Humic Acid on Fouling of Membrane)

  • 배진열;한인섭;박성호;신지원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.242-247
    • /
    • 2005
  • In this study, we investigated the removal efficiencies of pollutants and permeate fluxes depending on chemistry of feed water, various molecular weight cut-offs (MWCOs) and materials of membrane, operating pressure. We used seven MWCO membranes of YC0.5, YM1, YM3, YM10, YM30, YM100 and PM30, humic acid solution and surface water as feed water, and examined variation in permeate flux. Results of TOC removal experiment demonstrate that MWCO lower 1,000daltons could remove humic acid effectively. As increasing solution pH and decreasing divalent cations ($Ca^{2+}$) concentration, TOC removal increased. But $UV_{254}$ removal efficiency increased with higher divalent cation concentration and solution pH. Membrane fouling increased with increasing electrolyte (NaCl), divalent cation concentration and decreasing solution pH. In spite of initial permeate flux of the hydrophobic membrane (PM30) was higher than that of the hydrophilic membrane (YM30), flux decline of PM30 was significant during operation. At higher operating pressure, compactness of the cake layer on the membrane surface increased, resulting in gradual increase in hydraulic resistance.

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

역삼투막을 이용한 제철폐수 처리 시 실리카 및 철 이온이 막 폐색에 미치는 영향 (Effect of Silica and Iron on the Fouling Tendency of Reverse Osmosis Membrane for Treating Wastewater from an Integrated Iron and Steel Mill)

  • 오희완;이채영
    • 대한토목학회논문집
    • /
    • 제38권4호
    • /
    • pp.547-553
    • /
    • 2018
  • 제철공정에서 물 사용량은 조강 생산량 당 $4.2m^3$/톤으로 많으며 폐수의 성상에 있어서 철, 망간 등 물질을 포함하고 있다. 특히 동남아시아의 일부지역은 다른 지역에 비해 실리카의 농도가 높다. 실리카는 물 재이용을 위한 막 처리과정에서 막 폐색의 주된 요인으로 작용하기 때문에 물 재이용에 있어 제한요소이다. 실리카 농도가 높은 제철폐수의 경우 철 이온과 실리카에 의한 규산제일철 형성에 의한 막 폐색 발생우려가 높다. 본 연구는 두 가지 경우에 대하여 파일럿 테스트를 실시하였다. 제철폐수 처리수의 경우 RO 파일럿 테스트는 플럭스 15.9LMH 및 18.8LMH로 112일 동안 수행하였다. 실험결과 플럭스의 변동 및 차압(TMP, trans membrane pressure)이 크게 나타났으며, 최소 투과율은 78%로 낮아 막 폐색 가능을 확인할 수 있었다. 오탁수 처리수를 이용한 RO 파일럿 테스트는 플럭스 18.8LMH로 46일 동안 수행하였으며, 철 이온 농도는 0.11mg/l으로 폐수 처리수보다 낮았다. 실험결과 철 이온 등의 농도가 낮은 오탁수 처리수는 플럭스 및 TMP의 변동이 작아 RO 막 폐색현상이 폐수 처리수보다 저감됨을 알 수 있었다. 유입수 조건이 실리카, 철 및 망간 농도가 높은 경우 MF 전처리를 통해 RO 막 폐색현상을 저감시킬 수 있었다.