• Title/Summary/Keyword: Fouling Sensor

Search Result 10, Processing Time 0.032 seconds

A Study on the Diagnostic Technology for Fouling Occurred in Heat Exchanger (열교환설비에서의 파울링 진단기술에 관한 연구)

  • Chung Kyung-Yul;Rhyu Keel-Soo;Lee Hoo-Rach
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.502-508
    • /
    • 2005
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried. e.g., diagnosis of fouling, reducing and eliminating the fouling. etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously. The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall. The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator. In addition to, we showed the data that have been executed in field test for reliability verification.

A Study on The Diagnostic Technology for Fouling Occurred in Heat Exchanger. (열 교환설비에서의 파울링 진단기술에 관한 연구)

  • 정경열;이후락;박정일;김상렬;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.181-186
    • /
    • 2002
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried, e.g., diagnosis of fouling, reducing and eliminating the fouling, etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator.

  • PDF

Studies on Membrane Fouling Monitoring by Fluorescence Nano Particle and Fluorescent Spectrometry (형광 나노 입자 및 형광 분광 분석을 이용한 막오염 측정법 연구)

  • Seo, Mi-Rae;Nam, Mi-Yeon;Kim, Beom-Sik;Nam, Seung-Eun;Kim, In-Chul;Park, You-In
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.163-170
    • /
    • 2011
  • Membrane fouling control in water treatment may be the main obstacle for wider implementation and lower cost. A novel fluorescent spectroscope sensor device for membrane fouling integrity monitoring has been developed and evaluated in this study. PSf membranes for water treatment has been fabricated with three types of organic fluorescent materials, OB, FP, KCB. The fluorescent signal from membrane surface was analyzed throughout the filtration process. It was found that the fluorescent signal due to the membrane fouling decreased and the developed device is reliable for membrane fouling monitoring.

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

Building Grid Map for Detection Biofouling of Side Bottom Using Low-Cost SONAR Sensor Based on Raspberry Pi 4 (라즈베리 파이 4 기반의 저가형 소나 센서를 이용한 선저하부 오손생물 탐지를 위한 격자지도 작성)

  • Seol, Kwon;Lee, Jonghyun;Kwon, Hyukin;Kim, Hyeongseok;Ahn, Haesung;Cha, Eunyoung;Kim, Jeongchang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2021.06a
    • /
    • pp.283-285
    • /
    • 2021
  • 본 논문에서는 수중에서 선박 하부에 붙은 오손생물(fouling organism)을 탐지하고 격자지도(grid map)로 나타내는 시스템을 제안한다. 제안하는 시스템은 소나(sound navigation and ranging: SONAR) 센서와 오손생물사이의 시간 데이터를 수집한 후, 라즈베리 파이 4(raspberry pi 4)에서 수집된 데이터를 이용해 격자지도에 맵핑(mapping)함으로써, 선저하부의 상태를 파악하는데 도움을 줄 수 있다. 본 논문에서는 제안된 지도 시스템을 이용하여 선박 하부에 붙은 오손생물의 분포를 확인할 수 있다.

  • PDF

A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane (암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구)

  • Kang, Heeseok;Lee, Euijong;Kim, Hyungsoo;Jang, Am
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.

Validation of Salinity Data from ARGO Floats: Comparison between the Older ARGO Floats and that of Later Deployments

  • Youn Yong-Hoon;Lee Homan;Chang You-Soon;Thadathil Pankajakshan
    • Journal of the Korean earth science society
    • /
    • v.26 no.2
    • /
    • pp.129-136
    • /
    • 2005
  • Continued observation of ARGO floats for years(about 4 years) makes the conductivity sensor more vulnerable to fouling by marine life and associated drift in salinity measurements. In this paper, we address this issue by making use of floats deployed in different years. Floats deployed in the East Sea and the Indian Ocean are examined to find out float-to-float match-ups in such a way that an older float pops up simultaneously with a newer deployment (with tolerable space-time difference). A time difference of less than five days and space difference of less than 100km are considered for the match-up data sets. For analysis of the salinity drift under the stable water mass, observations of the floats from deepest water masses have been used. From the cross-check of ARGO floats in the East Sea and the Indian Ocean, it is found that there is a systematic drift in the older float compared to later deployments. All drift results, consistently show negative bias indicating the typical nature of drift from fouled sensors. However, the drift is much less than 0.01, the specified accuracy of ARGO program.

Characterization of Nafion Coated Non-enzymatic Glucose Sensor in Human Plasma and Whole Blood (나피온을 이용하여 패키징된 무효소 혈당센서의 혈장 및 전혈에서의 특성 평가)

  • Lee, Yi-Jae;Kim, Jung-Doo;Park, Jae-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1474-1475
    • /
    • 2008
  • 본 논문에서는 nanoporous Pt (Platinum) 전극을 이용한 무효소 혈당센서의 생체 적합성 및 전류응답 특성 향상을 위해 다양한 패키징 방법이 제안되었다. 생체적합성을 갖는 Nafion 멤브레인을 dipping, spin coating, chemical bonding 방법으로 패키징 한 후, 다양한 글루코오스 농도의 혈장, 전혈에서 특성을 분석, 비교하였다. 단백질 등이 포함되지 않은 환경에서 spin coating 방법으로 패키징한 센서의 전류응답 특성은 가장 좋았지만, 혈장 및 전혈에서는 dipping, chemical bonding 방법으로 패키징한 센서의 전류응답 특성에 미치지 못했다. Nafion film을 센서와 chemical bonding한 센서의 혈장에서 sensitivity 는 0.32 ${\mu}A/mM{\cdot}cm^2$ 이었다. 한편, 전혈에서 bare 센서가 급격한 bio-fouling 현상을 보이는 반면 패키징한 센서는 글루코오스 농도에 따라 일정한 전류변화를 보였다. 이는 Nafion을 이용하여 패키징한 무효소 혈당 센서가 생체환경에 적합할 뿐 아니라 생체이식형 및 연속 측정 가능한 시스템에 적용 가능함을 보여준다.

  • PDF

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Quality Control of Observed Temperature Time Series from the Korea Ocean Research Stations: Preliminary Application of Ocean Observation Initiative's Approach and Its Limitation (해양과학기지 시계열 관측 자료 품질관리 시스템 구축: 국제 관측자료 품질관리 방안 수온 관측 자료 시범적용과 문제점)

  • Min, Yongchim;Jeong, Jin-Yong;Jang, Chan Joo;Lee, Jaeik;Jeong, Jongmin;Min, In-Ki;Shim, Jae-Seol;Kim, Yong Sun
    • Ocean and Polar Research
    • /
    • v.42 no.3
    • /
    • pp.195-210
    • /
    • 2020
  • The observed time series from the Korea Ocean Research Stations (KORS) in the Yellow and East China Seas (YECS) have various sources of noise, including bio-fouling on the underwater sensors, intermittent depletion of power, cable leakage, and interference between the sensors' signals. Besides these technical issues, intricate waves associated with background tidal currents tend to result in substantial oscillations in oceanic time series. Such technical and environmental issues require a regionally optimized automatic quality control (QC) procedure. Before the achievement of this ultimate goal, we examined the approach of the Ocean Observatories Initiative (OOI)'s standard QC to investigate whether this procedure is pertinent to the KORS. The OOI QC consists of three categorized tests of global/local range of data, temporal variation including spike and gradient, and sensor-related issues associated with its stuck and drift. These OOI QC algorithms have been applied to the water temperature time series from the Ieodo station, one of the KORS. Obvious outliers are flagged successfully by the global/local range checks and the spike check. Both stuck and drift checks barely detected sensor-related errors, owing to frequent sensor cleaning and maintenance. The gradient check, however, fails to flag the remained outliers that tend to stick together closely, as well as often tend to mark probably good data as wrong data, especially data characterized by considerable fluctuations near the thermocline. These results suggest that the gradient check might not be relevant to observations involving considerable natural fluctuations as well as technical issues. Our study highlights the necessity of a new algorithm such as a standard deviation-based outlier check using multiple moving windows to replace the gradient check and an additional algorithm of an inter-consistency check with a related variable to build a standard QC procedure for the KORS.