• Title/Summary/Keyword: Forward Mode

Search Result 328, Processing Time 0.031 seconds

Mode localization and frequency loci veering in an aircraft with external stores

  • Liu, J.K.;Chan, H.C.
    • Structural Engineering and Mechanics
    • /
    • v.8 no.2
    • /
    • pp.181-191
    • /
    • 1999
  • This paper presents an investigation of the mode localization and frequency loci veering phenomena in an aircraft with disordered external stores. Two theoretical analyses are carried out to study the occurring mechanism of the two phenomena: condensation technique in the subspace spanned by modes of interest and geometric mapping theory in the complex plane. Two simple criteria for predicting the occurrence of the mode localization and frequency loci veering are put forward. The prediction of the phenomena by our theoretically proposed criteria is in good agreement with that obtained through numerical calculations of characteristic solutions of the disordered system.

Sliding Mode Fuzzy Control for Wind Vibration Control of Tall Building (Sliding Mode Fuzzy Control을 사용한 바람에 의한 대형 구조물의 진동제어)

  • 김상범;윤정방
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.79-83
    • /
    • 2000
  • A sliding mode fuzzy control (SMFC) with disturbance estimator is applied to design a controller for the third generation benchmark problem on an wind-excited building. A distinctive feature in vibration control of large civil infrastructure is the existence of large disturbances, such as wind, earthquake, and sea wave forces. Those disturbances govern the behavior of the structure, however, they cannot be precisely measured, especially for the case of wind-induced vibration control. Since the structural accelerations are measured only at a limited number of locations without the measurement of the wind forces, the structure of the conventional control may have the feed-back loop only. General structure of the SMFC is composed of a compensation part and a convergent part. The compensation part prevents the system diverge, and the convergent part makes the system converge to the sliding surface. The compensation part uses not only the structural response measurement but also the disturbance measurement, so the SMFC has a feed-back loop and a feed-forward loop. To realize the virtual feed-forward loop for the wind-induced vibration control, disturbance estimation filter is introduced. the structure of the filter is constructed based on an auto regressive model for the stochastic wind force. This filter estimates the wind force at each time instance based on the measured structural responses and the stochastic information of the wind force. For the verification of the proposed algorithm, a numerical simulation is carried out on the benchmark problem of a wind-excited building. The results indicate that the present control algorithm is very efficient for reducing the wind-induced vibration and that the performance indices improve as the filter for wind force estimation is employed.

  • PDF

Higher-order PMD compensator using partially feed forward algorithm (부분적인 feed forward 제어 알고리즘을 사용한 고차 PMD 보상에 대한 연구)

  • 김나영;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.72-79
    • /
    • 2003
  • We proposed a noble algorithm using DOP (degree of polarization) not only as feedback signal but alto as feed-forward signal for the compensation of higher-order PMD effect. In the proposed algorithm, DOP after the first-order PMD compensation is considered as the indicator of the amount of residual higher-order PMD. This algorithm has the merit that DOF (degree of freedom) of the system can be limited to the level of the first-order PMD compensation system. Owing to the limited DOF, the reliability of the system can be enhanced and the complexity of the implementation can be degraded. For the analysis of the algorithm, we simulated the 10Gbps NRZ transmission system and obtained the result that the system outage probability can be reduced as much as three times with respect to the only first-order PMD compensation case.

Power Supply Designer를 이용한 Forward Converter의 적용 및 특성평가

  • 문영제
    • KIPE Magazine
    • /
    • v.9 no.4
    • /
    • pp.28-31
    • /
    • 2004
  • 최근 전자제품의 소형경량화가 이루어지면서 전원장치의 고밀도화를 요구하고 있다. 이러한 기술동향에 따라 최근 DC-DC Converter를 소형, 고효율화하려는 연구가 매우 활발하게 이루어지고 있다. 각종 전자통신기기의 직류안정화 전원으로 폭넓게 이용되고 있는 Switch Mode Power Supply(SMPS) 중에 For-ward Converter에 대한 특성과 설계방법을 Simulation Program인 Power Supply Designer를 이용하여 알아보기로 한다.(중략)

CLR Performance Improvement of Random Traffic in the Wireless ATM Access Architecture (무선 ATM 접속구조에서 랜덤 트래픽의 셀 손실율 성능개선)

  • 김철순;이하철;곽경섭
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.7
    • /
    • pp.1239-1244
    • /
    • 2003
  • In this paper, we analyzed cell loss rate performance for random traffic sources in wireless ATM(Asynchronous Transfer Mode) access architecture, which consists of access node and wireless channel. Applying queueing model to cell level at access node and considering burst error characteristics in wireless channel, we derived a formula about the cell loss rate of the random traffic in the wireless ATM access architecture. We also applied FEC(Forward Error Correction) schemes to improve the cell loss rate of random traffic. When we applied FEC schemes in the wireless ATM access architecture, we confirmed that the concatenated code provides the most superior performance compared to any other codes.

  • PDF

Power Allocation for Opportunistic Full-Duplex based Relay Selection in Cooperative Systems

  • Zhong, Bin;Zhang, Dandan;Zhang, Zhongshan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.10
    • /
    • pp.3908-3920
    • /
    • 2015
  • In this paper, performance analysis of full-duplex (FD) relay selection under decode-and-forward (DF) relaying mode is carried out by taking into account several critical factors, including the distributions of the received signal-to-noise ratio (SNR) and the outage probability of wireless links. The tradeoff between the FD and half-duplex (HD) modes for relay selection techniques is also analyzed, where the former suffers from the impact of residual self-interference, but the latter requires more channel resources than the former (i.e., two orthogonal channels are required). Furthermore, the impact of optimal power allocation (OPA) on the proposed relay-selection scheme is analyzed. Particularly, the exact closed-form expressions for outage probability of the proposed scheme over Rayleigh fading channels are derived, followed by validating the proposed analysis using simulation. Numerical results show that the proposed FD based scheme outperforms the HD based scheme by more than 4 dB in terms of coding gain, provided that the residual self-interference level in the FD mode can be substantially suppressed to the level that is below the noise power.

Research on axial bearing capacity of cold-formed thin-walled steel built-up column with 12-limb-section

  • Wentao Qiao;Yuhuan Wang;Ruifeng Li;Dong Wang;Haiying Zhang
    • Steel and Composite Structures
    • /
    • v.47 no.3
    • /
    • pp.437-450
    • /
    • 2023
  • A half open cross section built-up column, namely cold-formed thin-walled steel built-up column with 12-limbsection (CTSBC-12) is put forward. To deeply reveal the mechanical behaviors of CTSBC-12 under axial compression and put forward its calculation formula of axial bearing capacity, based on the previous axial compression experimental research, the finite element analysis (FEA) is conducted on 9 CTSBC-12 specimens, and then the variable parameter analysis is carried out. The results show the FEA is in good agreement with the experimental research, the ultimate bearing capacity error is within 10%. When the slenderness ratio is more than 96.54, the ultimate bearing capacity of CTSBC-12 decreases rapidly, and the failure mode changes from local buckling to global buckling. With the local buckling failure mode unchanged, the ultimate bearing capacity decreases gradually as the ratio of web height to thickness increases. Three methods are used for calculating the ultimate bearing capacity, the direct strength method of AISI S100-2007 gives result of ultimate axial load which is closest to the test and FEA results. But for simplicity and practicality, a simplified axial bearing capacity formula is proposed, which has better calculation accuracy with the slenderness ratio changing from 30 to 100.

Seawater-driven forward osmosis for direct treatment of municipal wastewater

  • Sun, Yan;Bai, Yang;Tian, Jiayu;Gao, Shanshan;Zhao, Zhiwei;Cui, Fuyi
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.449-462
    • /
    • 2017
  • Direct treatment of municipal wastewater by forward osmosis (FO) process was evaluated in terms of water flux decline, reverse salt diffusion, pollutants rejection and concentration efficiency by using synthetic seawater as the draw solution. It was found that when operating in PRO mode (active layer facing the draw solution), although the FO membrane exhibited higher osmotic water flux, more severe flux decline and reverse salt diffusion was also observed due to the more severe fouling of pollutants in the membrane support layer and accompanied fouling enhanced concentration polarization. In addition, although the water flux decline was shown to be lower for the FO mode (active layer facing the feed solution), irreversible membrane fouling was identified in both PRO and FO modes as the water flux cannot be restored to the initial value by physical flushing, highlighting the necessity of chemical cleaning in long-term operation. During the 7 cycles of filtration conducted in the experiments, the FO membrane exhibited considerably high rejection for TOC, COD, TP and $NH_4{^+}-N$ present in the wastewater. By optimizing the volume ratio of seawater draw solution/wastewater feed solution, a concentration factor of 3.1 and 3.7 was obtained for the FO and PRO modes, respectively. The results demonstrated the validity of the FO process for direct treatment of municipal wastewater by using seawater as the draw solution, while facilitating the subsequent utilization of concentrated wastewater for bioenergy production, which may have special implications for the coastline areas.

Outage Performance Analysis of Partial Relay Selection Based Opportunistic Cooperation in Decode-and-Forward Relaying Systems (디코딩 후 전달 중계 시스템에서 부분 중계 노드 선택 기법 기반 기회적 협력 방식의 아웃티지 성능 분석)

  • Lee, Sangjun;Lee, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1804-1810
    • /
    • 2013
  • In this paper, we study the opportunistic cooperation scheme that improves the outage performance through the efficient selection between a cooperative mode and a non-cooperative mode. Especially, in decode-and-forward relaying systems, we analyze the outage performance for the opportunistic cooperation using partial relay selection, where closed-form expressions of exact and asymptotic outage probabilities are derived assuming independent and identically distributed Rayleigh fading channels. In the numerical results, we verify the derived expressions, and investigate the outage performances for various target data rates and different numbers of relays. Also, we compare the outage performances of the conventional cooperation scheme and the opportunistic cooperation scheme.

A Study of the Output Characteristics of a 1-kW-class Narrow-bandwidth PM Fiber Laser Depending on Its Pumping Structure (펌핑 구조에 따른 1 kW급 협대역 편광 유지 광섬유 레이저의 출력 특성 연구)

  • Kim, Tae Hyoung;Jeong, Seong Mook;Kim, Ki Hyuck;Lee, Sung Hun;Yang, Hwan Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.187-194
    • /
    • 2021
  • This paper presents a study of laser output characteristics. We fabricated a MOPA (master oscillator power amplifier)-type high-power, narrowbandwidth fiber laser with a bidirectional pumping configuration in its main amplifier. As signal beams, light sources with bandwidths of 3 GHz and 10 GHz-phase-modulated through a PRBS (pseudo-random binary sequence)-were used interchangeably. Furthermore, the characteristics of the SBS (stimulated Brillouin scattering) were analyzed using a signal beam with 3 GHz bandwidth, by adjusting the forward to backward pumppower ratio. Moreover, the characteristics of the transverse mode instability were analyzed by adjusting the forward to backward pump-power ratio, using a signal beam with 10-GHz bandwidth. Finally, the output power from 10 GHz bandwidth was amplified to more than 1 kW using a forward to backward pump-power ratio of 1.6. The beam quality M2 was measured to be approximately 1.36, and the optical-to-optical efficiency was 80% at maximum output power.