• Title/Summary/Keyword: Form of current

Search Result 2,603, Processing Time 0.028 seconds

Boost AC-DC Converter of High Power Factor and High Efficiency (고역률 고효율 승압형 AC-DC 컨버터)

  • Kwak, Dong-Kurl;Kim, Choon-Sam;Park, Ha-Yong;Shim, Jae-Sun;Shim, Sang-Heung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.7
    • /
    • pp.45-52
    • /
    • 2005
  • This paper is studied on boost AC-DC converter of high power factor and high efficiency for discontinuous current control. The converter operated in discontinuous current control eliminates the complicated circuit control requirement, and reduces a number of components. The input current waveform in proposed circuit is got to be a discontinuous sinusoidal form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control circuit is simple. Also the switching devices in a proposed circuit are operated with soft switching by the partial resonant method. The result is that the switching loss is very low and the efficiency of system is high. The partial resonant circuit makes use of a inductor using step up and loss-less snubber capacitor. The circuit topology of the converter is simplified. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

Comparison of nonlinear 1$1/2$-layer and 2$1/2$-layer numerical models with strong offshore winds and the Tsushima Current in the East Sea

  • Kim, Soon-Young;Lee, Hyong-Sun;Dughong Min;Yoon, Hong-Joo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.91-103
    • /
    • 1999
  • According to numerical experiments, the Sokcho Eddy is produced at $37 5~39.0^{\circ}N$ by strong offshore winds, whereas the Ulleung Eddy is produced at $35~37^{\circ}N$ by an inflow variation of the Tsushima Current. These locations compare well with visual observations. The nonlinear 1$1/2$-layer model showed that most of the East Korea Warm Current (EKWC) driven by the Tsushima Current form the Ulleung Eddy that is larger and stronger than the Sokcho Eddy. In contrast, the nonlinear 2$1/2$-layer model showed that most of the EKWC travels further northward due to a strong subsurface current, thereby enhancing the Sokcho Eddy making it larger and stronger than the Ulleung Eddy. The Sokcho Eddy is also produced relatively offshore due to an eastward subsurface current in the frontal region. Using the 1$1/2$-layer model, when the mass of the Tsushima Current decreases, the two eddies are weakened and produce a circular shape. In the 2$1/2$-layer model the EKWC pushes the Ulleung Eddy northward after 330 days, next the Sokcho and Ulleung eddies begin to interact with each other, and then after 360 days the Ulleung Eddy finally disappears absorbed by the relatively stronger Sokcho Eddy. This behavior compares favorably with other visual observations.

  • PDF

A study on Problems of Charterparty for Tug & barge Ship which Employed in Marine Construction and its Systematic Improvement Plan (해상공사에 투입된 예·부선 용선계약의 문제점과 개선방안에 관한 연구)

  • Jang, Yeong-Jun
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.471-477
    • /
    • 2014
  • In general, a regular charterparty form is used as a charterparty for tugboats which are employed in marine construction and a bareboat charter form is generally used for barge boat charterparty. As the tug-barge charterparty which are currently used do not have a standardised form, contracting parties arbitrarily decide on the terms and conditions of the contract. As a result, provisions of the charterparty usually do not specify in the contract which party bears the burden of liability in case of accident. Furthermore, the terminologies used in the charterparty are different from legal terms of current commercial law which causes confusion. These problems can be solved mostly by clarifying the legal character of the charterparty between the contracting parties and by conforming the terminologies. In addition, endeavour to standardise the contract form must be carried forward at the same time. This research purports to study actual condition of current charterparty for tug-barge ship which are employed to marine construction and to suggest systematic improvement plan. For this purpose, this research focuses on studying cases in which dispute arose due to lack of clarity in the provisions of the contract with regard to which party bears the burden of liability in case of accident. This research also purports to suggest forming the standardised contract terms of the charterparty as one way of solution and examine matters to be attended in writing a standardised form.

Enterprise Network Weather Map System using SNMP (SNMP를 이용한 엔터프라이즈 Network Weather Map 시스템)

  • Kim, Myung-Sup;Kim, Sung-Yun;Park, Jun-Sang;Choi, Kyung-Jun
    • The KIPS Transactions:PartC
    • /
    • v.15C no.2
    • /
    • pp.93-102
    • /
    • 2008
  • The network weather map and bandwidth time-series graph are popularly used to understand the current and past traffic condition of NSP, ISP, and enterprise networks. These systems collect traffic performance data from a SNMP agent running on the network devices such as routers and switches, store the gathered information into a DB, and display the network performance status in the form of a time-series graph or a network weather map using Web user interface. Most of current enterprise networks are constructed in the form of a hierarchical tree-like structure with multi-Gbps Ethernet links, which is quietly different from the national or world-wide backbone network structure. This paper focuses on the network weather map for current enterprise network. We start with the considering points in developing a network weather map system suitable for enterprise network. Based on these considerings, this paper proposes the best way of using SNMP in constructing a network weather map system. To prove our idea, we designed and developed a network weather map system for our campus network, which is also described in detail.

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

Analysis of Conduction-Path Dependent Off-Current for Asymmetric Double Gate MOSFET (비대칭 이중게이트 MOSFET의 차단전류에 대한 전도중심 의존성 분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.575-580
    • /
    • 2015
  • Asymmetric double gate(DG) MOSFET is a novel transistor to be able to reduce the short channel effects. This paper has analyzed a off current for conduction path of asymmetric DGMOSFET. The conduction path is a average distance from top gate the movement of carrier in channel happens, and a factor to change for oxide thickness of asymmetric DGMOSFET to be able to fabricate differently top and bottom gate oxide thickness, and influenced on off current for top gate voltage. As the conduction path is obtained and off current is calculated for top gate voltage, it is analyzed how conduction path influences on off current with parameters of oxide thickness and channel length. The analytical potential distribution of series form is derived from Poisson's equation to obtain off current. As a result, off current is greatly changed for conduction path, and we know threshold voltage and subthreshold swing are changed for this reasons.

Preparation of Porous Cobalt Thin Films by Using an Electrochemical Method (전기화학적 방법을 통한 다공성 코발트 박막 합성)

  • Ha, Seong-Hyeok;Shin, Heon-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.6
    • /
    • pp.312-321
    • /
    • 2020
  • Morphology of porous cobalt electro-deposits was systematically investigated as functions of cobalt precursors in the plating bath and applied cathodic current density with a special focus on cobalt nano-rod formation. It was proved that the concentration of cobalt precursor plays little effect on the morphology of cobalt electro-deposits at relatively low plating current density while it significantly affects the morphology with increasing plating current density. Such a dependence was discussed in terms of the kinetics of two competitive reactions of cobalt reduction and hydrogen evolution. Cobalt nano-rod structure was created at specific ranges of cobalt precursor content and applied cathodic current density, and its diameter and length varied with plating time without notable formation of side branches which is usually found during dendrite formation. Specifically, the nano-rod length was preferentially increased in relative short plating time (<15 s), resulting in higher aspect ratio of nano-rod with plating time. Whereas, both the nano-rod length and diameter were increased nearly at the same level in a prolonged plating time, making the aspect ratio unchanged. From the analysis of crystal structure, it was confirmed that the cobalt nano-rod preferentially grew in the form of single crystal on a dense poly-crystalline cobalt thin film initially formed on the substrate.

A Study on DC Offset Removal using Low-Pass Filter in AT Feeder System for Electric Railway (전기철도 AT급전계통에 Low-Pass Filter를 이용한 직류옵셋 제거에 관한 연구)

  • Lee, Hwan;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1108-1114
    • /
    • 2016
  • The cause of failure in the AT feeding system is divided into grounding, short-circuit of feeding circuit and internal faults of the railway substation. Since the fault current is very high, real-time current is detected and the failure must be immediately removed. In this paper, a new DC offset elimination filter that can remove component to decrease in the form of exponential function using low-pass filter was proposed in order to extract the fundamental wave from distorted fault current. In order to confirm the performance of the proposed filter method, AT feeder system was modelled by simulation tool and simulations were performed under various conditions such as fault location, fault resistance and fault voltage phase angle in case of trolley-rail short-circuit fault. When applying the proposed DC-offset removal method, it can be seen that the phase delay and gain error did not appear.

A Study on the Problem about Oriental Treatment Fee Based on Valuation of Resources (투입자원 평가에 근거한 한방 침구 부항 시술 수가의 문제점에 관한 연구)

  • Kim, Yong-Ho;Lee, Won-Hui;Chang, Hye-Jung;Lim, Sa-Bi-Na
    • The Journal of Korean Medicine
    • /
    • v.29 no.1
    • /
    • pp.15-24
    • /
    • 2008
  • Objectives : The purpose of this study is to reexamine current oriental medical treatment fees based on valuation of input resources which are the treating time, the treatment's difficulty, and the material cost. Methods : This study obtained the following results by reviewing the answers given by 172 oriental medical doctors from March 1 to April 15, 2006. To investigate material cost, we took inventory of treatment materials used by 2 oriental hospitals. Results : The current system does not reflect well enough the treating time and treatment's difficulty. Considering current oriental treatment fees, material costs are too much of doctors' fees. Especially, Wang-ssuk-dduem, which is another form of moxibustion treatment, was spent as much as 74.6% on materials cost. Conclusions : The findings suggest the current oriental treatment fees should be revised to reflect the actual input resources into oriental medical doctor activities and to avoid a distortion of physicians' behavior.

  • PDF

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.