• 제목/요약/키워드: Forensic Science

검색결과 454건 처리시간 0.023초

Development and validation of a qualitative GC-MS method for methamphetamine and amphetamine in human urine using aqueous-phase ethyl chloroformate derivatization

  • Kim, Jiwoo;Sim, Yeong Eun;Kim, Jin Young
    • 분석과학
    • /
    • 제33권1호
    • /
    • pp.23-32
    • /
    • 2020
  • Methamphetamine (MA) is the most common and available drug of abuse in Korea and its primary metabolite is amphetamine (AP). Detection of AP derivatives, such as MA, AP, phentermine (PT), MDA, MDMA, and MDEA by the use of immunoassay screening is not reliable and accurate due to cross-reactivity and insufficient specificity/sensitivity. Therefore, the analytical process accepted by most urine drug-testing programs employs the two-step method with an initial screening test followed by a more specific confirmatory test if the specimen screens positive. In this study, a gas chromatography-mass spectrometric (GC-MS) method was developed and validated for confirmation of MA and AP in human urine. Urine sample (500 µL) was added with N-isopropylbenzylamine as internal standard and ethyl chloroformate as a derivatization reagent, and then extracted with 200 µL of ethyl acetate. Extracted samples were analysed with GC-MS in the SIM/ Scan mode, which were screened by Cobas c311 analyzer (Roche/Hitachi) to evaluate the efficiency as well as the compatibility of the GC-MS method. Qualitative method validation requirements for selectivity, limit of detection (LOD), precision, accuracy, and specificity/sensitivity were examined. These parameters were estimated on the basis of the most intense and characteristic ions in mass spectra of target compounds. Precision and accuracy were less than 5.2 % (RSD) and ±14.0 % (bias), respectively. The LODs were 3 ng/mL for MA and 1.5 ng/mL for AP. At the screening immunoassay had a sensitivity of 100% and a specificity of 95.1 % versus GC-MS for confirmatory testing. The applicability of the method was tested by the analysis of spiked urine and abusers' urine samples.

CNG 차량 폭발의 용기 손상 평가에 관한 법공학적 연구 (Forensic Engineering Study on Assessment of Damage to Pressure Vessel Because of CNG Vehicle Explosion)

  • 김의수
    • 대한기계학회논문집A
    • /
    • 제35권4호
    • /
    • pp.439-445
    • /
    • 2011
  • 대기오염 등 환경에 대한 관심이 높아지면서 경유차 배출 가스 저감을 위한 최적의 대안으로 최근 세계적으로 천연가스차량의 보급이 크게 확대되고 있는 추세이다. 이러한 추세에도 불구하고 그 안전성에 대해서는 많은 논란을 불러 일으키고 있으며 최근 그 이용에 따른 안전사고 또한 빈번하게 발생하고 있다. 천연가스버스 압력용기 파열 사고는 대중들이 많이 이용한다는 점에서 대형참사로 이어질 수 있는 잠재력을 가지고 있어 그 심각성은 매우 크다고 할 수 있다. 이에 법공학적인 측면에서 좀 더 전문화되고 체계적인 사고조사와 원인 규명을 통해서 사전에 예방대책을 마련함으로써 유사 및 동종재해의 발생을 최소화해야 한다. 본 연구에서는 구조해석을 통한 용기의 설계 검증과 용기의 파손형태 검사 및 재료 물성평가 등을 통해 용기파손에 의한 CNG 차량 폭발 사고에 관한 정확한 사고 원인을 규명함으로써 동일 형태의 차량 안전사고 예방에 기여하고자 한다.

소사체 치아에서의 유전자지문 분석을 위한 실험적 연구 (Experimental Study for DNA Fingerprint from Teeth of Charred Body)

  • Jong-Hoon Choi
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.351-367
    • /
    • 1996
  • In the field Of individual identification in forensic Science, if the body is charred, it is sometimes impossible to identify the morphologic changes and charred tissue such as blood, muscle and bone can not be identified by forensic microbiologic method such as DNA typing. So the author used the characteristics of teeth which is relatively firm compare to other organs and stable to external environment such as heat and also possess cells needed for the DNA typing. The author conducted the experiment on teeth to detect DNA related to individual identification regarding to temperature in which other charredorgans can not be detected. The experiment was done on 64 extracted third molars consisted of unheated ones, and heated teeth to $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$ for 45 min, 90 min, and 120 min respectively and to $250^{\circ}C$ for 45 min. DNA was extracted from each tooth and amplified fragment length polymorphism procedure(AMP-FLPs) using polymerase chain reaction(PCR) was applied and observed for the matching DNA in HumTH01 and HumCD4 locus and the followings Are the results : 1. It was able to detect matching DNA in HumTH01 and HumCD4 locus in every teeth which no heating has been done. 2. It was able to detect matching DNA in HumTH01 and HumCD4 locus in every teeth heated to $100^{\circ}C$ for 45, 90 and 120 min. 3. It was able to detect matching DNA in HumTH01 and HumCD4 locus in teeth heated to $l00^{\circ}C$, $200^{\circ}C$ for 45, 90, 120 min. 4. It was impossible to detect matching DNA in HumTH01 and HumCD4 locus in teeth heated to $250^{\circ}C$. So, it is possible to extract DNA from teeth that otherwise can not be extracted from other organs in the charred body and it can be concluded that teeth are highly reliable and applicatable as forensic odontology for individual identification.

  • PDF

코드화 다공성 실리콘 나노입자의 개발 및 법과학적 응용 (The development of encoded porous silicon nanoparticles and application to forensic purpose)

  • 신여울;강상혁;이준배;팽기정
    • 분석과학
    • /
    • 제22권3호
    • /
    • pp.247-253
    • /
    • 2009
  • 단결정의 실리콘 웨이퍼를 hydrofluoric acid와 ethyl alcohol이 혼합된 용액에 담궈 적정한 전류를 흘려주면 웨이퍼 표면에 수많은 pore를 형성하면서 에칭되어진다. 이러한 pore의 형태와 porosity는 전류 값과 에칭 시간 및 주기를 변화시켜 쉽게 조절할 수 있는데, 이렇게 제작된 다공성 실리콘은 수백 $m^2/cm^3$의 큰 표면적을 가지게 된다. 이때 sin 파와 같은 모양으로 시간대별 가해지는 전류 밀도를 다르게 해주어 pore안쪽의 모양을 변화시켜 주어 가시광선 영역에서 하나의 spectrum을 나타나게 되는 rugate 박막을 제작 한다. 본 연구에서는 법과학적인 목적으로 코드화된 다공성 실리콘의 rugate film을 이용하여 nano particle을 제작한 다음 이 입자들을 페인트에 혼합, 차량에 도포하고, 회수 후에 이를 확인할 수 있는지 조사하였다. 본 연구에서는 또 다양하게 가해지는 전류 값을 변경 또는 혼합하여 다공성 실리콘에 다양한 코드화를 시도하였으며, 사고 시 탈착한 페인트에서 다공성 실리콘 nano particle을 회수 하기위해 다공성 실리콘 안에 magnetite를 삽입하여 자석을 이용한 미량 나노입자 시료를 응집시켜 스펙트럼을 확인하였다.

Stature estimation using the sacrum in a Thai population

  • Waratchaya Keereewan;Tawachai Monum;Sukon Prasitwattanaseree;Pasuk Mahakkanukrauh
    • Anatomy and Cell Biology
    • /
    • 제56권2호
    • /
    • pp.259-267
    • /
    • 2023
  • Stature is an essential component of biological profile analysis since it determines an individual's physical identity. Long bone dimensions are generally used to estimate the stature of skeletal remains; however, non-long bones such as the sternum, cranium, and sacrum may be necessary for some forensic situations. This study aimed to generate a regression equation for stature estimation of the skeletal remains in the Thai population. Ten measurements of the sacrum were measured from 200 dry sacra. The results revealed that the maximum anterior breadth (MAB) provided the most accurate stature prediction model among males (correlation coefficient [r]=0.53), standard error of estimation (SEE=5.94 cm), and females (r=0.48, SEE=6.34 cm). For the multiple regression model, the best multiple regression models were stature equals 41.2+0.374 (right auricular surface height [RASH])+1.072 (anterior-posterior outer diameter of S1 vertebra corpus [APOD])+0.256 (dorsal height [DH])+0.417 (transverse inner diameter of S1 vertebra corpus [TranID])+0.2 (MAB) with a SEE of 6.42 cm for combined sex. For males, stature equals 63.639+0.478 (MAB)+0.299 (DH)+0.508 (APOD) with a SEE of 5.35, and stature equals 75.181+0.362 (MAB)+0.441 (RASH)+0.132 (maximum anterior height [MAH]) with a SEE of 5.88 cm for females. This study suggests that regression equations derived from the sacrum can be used to estimate the stature of the Thai population, especially when a long bone is unavailable.

대학병원 직원들의 부검에 대한 인식도 (Personnel's Perception toward Conducting an Autopsy in General Hospital)

  • 이호범;곽정식
    • 대한수사과학회지
    • /
    • 제2권2호
    • /
    • pp.30-49
    • /
    • 2007
  • 부검은 검안만으로 사인 또는 사망의 종류를 확인할 수 없는 경우 시체를 해부하여 이를 확인하는 검시(檢屍)방법이다. 본 연구자는 대학병원 직원들의 부검에 대한 인식도를 알아보기 위해 설문지를 이용하여 2007년 4월 2일부터 5월 4일까지 1개월간 대구광역시 영남대학교의료원의 직원들을 대상으로 설문조사를 실시하였다. 전체 286 명 중 남자가 121 명(42.3%), 여자가 165 명(57.7%)이었으며, 의사 57 명(19.9%), 간호사 71 명(24.8%), 의료기술직 83 명(29.0%), 행정사무직 58 명(20.3%), 기타 직종 17 명(5.9%)이었다.대상자들의 설문조사를 살펴보면 부검에 대한 교육정도에서 의사는 2회 이상이 61.4%인데, 간호사는 1.4%, 의료기술직은 15.7%, 행정사무직은 1.7%, 기타 직종은 5.9%로 의사들에 비해 교육정도가 많이 부족하였다. 본인이나 가족이 갑자기 쓰러져 사망했을 때 부검을 의뢰하겠는가라는 질문에 의사는 의뢰한다가 59.6%로 높았으나, 간호사는 22.5%, 의료기술직은 39.8%, 행정사무직은 41.4%, 기타 직종은 35.3%로 낮게 나타났다. 직장 동료가 근무 중 갑자기 쓰러져 사망한 경우 부검을 해야 한다고 생각하는가라는 질문에서도 의사는 그렇다가 66.7%로 높았으나, 간호사는 33.8%, 의료기술직은 39.8%, 행정사무직은 43.1%, 기타 직종은 17.6%로 낮게 나타났다. 병원내 환자가 병사했을 때 부검을 해야 한다고 생각하는가라는 질문에서도 의사는 그렇다가 50.9%, 간호사는 8.5%, 의료기술직은 19.3%, 행정사무직은 24.1%, 기타 직종은 17.6%로 낮게 나타났다. 부검은 어떤 곳에서 해야 하는가라는 질문에 의사는 의과대학 법의학교실이 73.7%로 가장 높았고, 다른 직종에서는 국립과학수사연구소가 가장 높게 나타났는데, 간호사는 62.0% 의료기술직은 59.0%, 행정사무직은 46.6%, 기타 직종은 58.8%이었다. 부검의 주체는 모든 직종에서 대부분의 대상자들이 전문 법의병리의사가 되어야 한다고 생각하는 것으로 나타났는데, 의사는 98.2%, 간호사는 94.4%, 의료 기술직은 96.4%, 행정사무직은 89.7%, 기타 직종은 88.2%이었다. 평소 부검의 필요성은 의사는 73.7%, 간호사는 23.9%, 의료기술직은 47.0%, 행정사무직은 34.5%, 기타 직종은 23.5%로 의사들이 평소 부검의 필요성을 많이 느끼는 것으로 나타났다. 사후 본인의 사체를 의과대학이나 연구기관 등에 기증할 용의가 있는가라는 질문에 의사는 22.8%, 간호사는 11.3%, 의료기술직은 24.1%, 행정사무직은 22.4%, 기타 직종은 23.5%만이 있다라고 답했다. 대상자들의 설문조사를 분석한 결과, 의사들에 비해 다른 직종의 대상자들이 부검에 대한 교육정도나 거부감이 더 큰 것으로 나타났다. 부검에 대한 부정적 의식의 개선을 위해 전문 인력의 양성과 관련 법률을 정비하여 우리나라 실정에 맞는 올바른 검시제도의 정착과 국민들에 대한 체계적인 법의학교육에 힘써야 할 것이다.

  • PDF

디지털 포렌식 관점에서의 인스타그램 사용자 행위 분석 (Instagram Users Behavior Analysis in a Digital Forensic Perspective)

  • 서승희;김역;이창훈
    • 정보보호학회논문지
    • /
    • 제28권2호
    • /
    • pp.407-416
    • /
    • 2018
  • 인스타그램(Instagram)은 사람 간의 관계망을 구축하고 취미, 일상, 유용한 정보 등을 공유하는 인터넷 서비스인 소셜 네트워크 서비스(Social Network Service:SNS)로 최근 다양한 연령층에서 각광받고 있다. 하지만 업로드한 개인 정보를 불특정 다수가 열람할 수 있고 검증되지 않은 정보가 무방비하게 공유되기 때문에 이를 악용한 각종 사기, 스토킹, 명의 도용, 저작권 침해, 악성코드 유포 등의 문제가 발생 하고 있다. 이에 따라 인스타그램에 대한 디지털 포렌식적 관점에서의 분석이 필요하나 관련한 연구는 미약한 실정이다. 따라서 본 논문에서는 안드로이드 환경에서 인스타그램에 대해 디지털 포렌식 관점에서 역 공학 및 동적 분석을 수행하였고 그 결과 채팅 내용, 채팅 대상, 게시한 사진, 쿠키 정보 등의 사용자 행위 분석이 가능한 데이터가 담긴 3개의 데이터베이스 파일과 4개의 파일 저장 경로, 다양한 데이터 저장된 xml파일을 확인하였다. 또한 위의 분석 결과를 디지털 포렌식 조사에 활용할 수 있는 방안을 제시한다.

Physical Developer(PD)의 신뢰성 테스트(reagent reliability test)를 위한 타겟물질 탐색과 TWEEN® 20 기반 PD 작업용액의 보관기간에 관한 연구 (Identifying the potential target substance of physical developer (PD) for reagent reliability test and a study on storage period of TWEEN® 20 based PD working solution)

  • 안수정;이예진;유제설
    • 분석과학
    • /
    • 제36권3호
    • /
    • pp.113-120
    • /
    • 2023
  • Physical developer (PD)는 젖었거나 탄화된 종이의 지문, 그리고 매우 오래된 종이의 지문까지도 현출할 수 있는 효과적인 기법이다. 하지만, 어떤 물질과 반응하는지 밝혀지지 않았고 작업용액의 보관기간에 따른 최적화 시점 또한 알려지지 않았다. PD를 좀 더 효과적으로 활용하기 위해서는 이 두가지 이슈를 해결해야 한다. 본 연구에서는 이를 위해 지문을 구성하는 것으로 알려진 수용성 물질 7가지와 지용성 물질 5가지로 spot test를 하였고 그 중 palmitic acid와 lysine의 혼합물이 PD와 가장 강하게 반응한다는 것을 알아내었다. 또한, 1,2-indanedione/zinc (1,2-IND/Zn) 용액을 처리하여 lysine이 용해되지 않았음을 확인하였다. 이 두 물질의 혼합물을 PD 작업용액의 지문 현출 성능을 시험하기 위한 신뢰성 테스트(reagent reliability test)의 타겟물질로 활용하여 TWEEN® 20 기반 PD 작업용액의 보관기간에 따른 최적화 시점을 확인하였다. 그 결과, 14일이 지났을 때 가장 뛰어난 결과를 나타냈으며 그 이후부터는 반응이 점점 약해졌다.

고체상 추출과 GC/MS를 이용한 소변 중 대마 대사체 (THCCOOH) 분석 (Determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine by solid-phase extraction and GC/MS)

  • 정재철;김진영;인문교;정원조
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.441-448
    • /
    • 2006
  • 소변 중 대마 남용여부를 판별하는데 기준이 되는 tetrahydrocannabinol (THC)의 대사체 성분인 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH)를 고체상 추출법 (solid-phase extraction, SPE)과 가스크로마토그래피/질량분석법 (GC/MS)을 이용하여 신속하게 분석 할 수 있는 방법을 제시하였다. 본 실험은 시험관에 소변 3 mL를 취해 염기성 (pH 10) 조건에서 가수분해 한 후, 양이온교환 카트리지를 사용하여 THCCOOH 성분을 선택적으로 추출하고, 증발 건고한 다음 유도체 반응을 시켜 GC/MS로 분석하였다. 그 결과 분석방법의 검출한계 (LOD)는 0.4 ng/mL이고, 정량한계 (LOQ)는 1.2 ng/mL이였다. 검정곡선의 직선성 상관계수 ($r^2$)는 1.2 (LLE는 1.3)~50.0 ng/mL의 농도범위에서 0.999를 나타내었다. 그리고 정밀도 (precision)와 정확도 (accuracy)는 모두 ${\pm}1.20%$ 이내로 안정적이었으며, 회수율(recovery)은 83.6~90.7%로 측정되었다. 액체상 추출법 (liquid-liquid extraction, LLE)과 비교할 때, SPE 방법이 회수율은 낮았지만 검출한계, 정량한계, 정밀도 및 정확도에서는 큰 차이가 없었다. 그러나 LLE 방법은 추출과정에 시간과 노력이 많이 드는 반면, SPE 방법은 상대적으로 추출 조작이 간편하고 신속하게 추출되었으며, 추출 잔류물도 깨끗하였다. SPE를 이용한 추출방법을 다수의 대마 흡연자 소변에 적용하였을 때 기존에 사용하던 LLE 방법보다 간편하고, 신속하게 대마 대사체 분석이 가능하였다.

고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법 (Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS)

  • 정재철;김진영;인문교;정원조
    • 분석과학
    • /
    • 제21권1호
    • /
    • pp.41-47
    • /
    • 2008
  • 소변 중 암페타민계 5성분(amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA)의 동시분석을 위하여 기존의 액체상추출(liquid-liquid extraction; LLE) 방법과는 달리 감정과정의 자동화가 가능한 고체상추출(solid-phase extraction, SPE) 방법을 도입하였다. 시험관에 소변 3 mL와 0.1 M 인산완충액 1 mL (pH 7.0)를 넣고, 자동추출장치를 이용하여 추출하고, 증발 건고하여 유도체화 한 다음 GC/MS로 분석하였다. 그 결과 검정곡선의 직선성 상관계수 ($r^2$)는 AP와 MDA [농도범위 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL] 및 MA, MDMA, MDEA (농도범위 50.0~2000.0 ng/mL)에서 0.994 이상으로 나타났다. 그리고 각 성분들의 검출한계 (LOD)는 4.0~10.0 ng/mL 범위였고, 정량한계 (LOQ)는 12.0~34.0 ng/mL 범위였다. 상대 회수율은 5성분 모두 93.5~107.7%로 측정되었다. 정밀도 (precision)와 정확도 (accuracy)는 각각 1.9~14.8%와 -8.7~14.8 % 범위 값을 나타냈다. 본 실험방법을 실제 남용자 소변에 적용한 결과 메스암페타민 또는 엑스터시 투약자를 신속하고 정확하게 동시에 확인할 수 있었다.