• 제목/요약/키워드: Forced condition

검색결과 281건 처리시간 0.032초

Critical Heat Flux under Forced and Natural Circulations of Water at Low-Pressure, Low-Flow Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.315-320
    • /
    • 1995
  • The CHF phenomenon has been investigated for water flow under forced and natural circulation modes with vertical round tubes at low pressure and low flow condition. Experiments have been performed by using three different test sections for mass fluxes below 400 kg/㎡s under near atmospheric pressure. The experimental data for forced and natural circulation are compared with each other. To predict the flow rate at the two-phase region our test condition has been analyzed by RELAP5/MOD3 because the local two-phase condition inside the stainless steel tube cannot be directly measured. To predict the CHF with accuracy we have to consider the parameters at the single-phase region as well as the flow behavior at the two-phase region.

  • PDF

Thermal Analysis of Transportation and Storage Cask of Spent Nuclear Fuel for Forced Gas Drying Condition

  • Lim, Suk-Nam;Chae, Gyung-Sun;Han, Jae-Hyun;Park, Jae-Seok;Lee, Dong-Gyu
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2017년도 춘계학술논문요약집
    • /
    • pp.153-154
    • /
    • 2017
  • The thermal analysis of transportation and storage cask for SNF was conducted during short term loading operations for forced gas drying condition. The fuel cladding temperature in 6 regions of SNF in the cask during the short term loading operations for forced gas drying condition is shown in the Fig. 3. The thermal analysis results of calculated maximum cladding temperature in each process demonstrate that operating scenario of TFD in detailed design maintain well below the temperature limits of $400^{\circ}C$.

  • PDF

CFD 해석을 이용한 한국도로공사 표준 25 [W] LED 모듈의 방열 특성 분석 (Analysis of Heat Dissipation Characteristics for Standard 25 [W] LED Module of Korea Expressway Corporation: Using CFD Analysis)

  • 이세일;허인성;이아람;정민주;유영문
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.541-546
    • /
    • 2014
  • Korea Expressway Corporation established standard of LED lighting fixture in Dec. 2013. To raise compatibility, the standard requires a fixed form and it is applied to street lights and tunnel lights, etc. Because streetlight has different circumstance condition from tunnel light that is down light and exposed to constant wind velocity over height of 8 meters, in case of LED module which has the same shape, characteristic of radiant heat can be different. In this paper, we designed 25 [W] LED Module that is designated by standard of Korea Expressway Corporation and analyzed characteristics of radiant heat about natural convection and forced convection. It is dropped 10.12[$^{\circ}C$] that max temperature is decreased by increasing 20 mm of bended height of heatsink at the condition of natural convection. Radiant heat characteristic of bended height 35 mm became 78.08[$^{\circ}C$] at the condition of natural convection, 55.30[$^{\circ}C$] at the condition of forced convection so that 22.78[$^{\circ}C$] is decreased that is 29.1[%] decrease. Bended height 55mm became 67.96[$^{\circ}C$] at the condition of natural convection, 48.04[$^{\circ}C$] at the condition of forced convection so that 19.92[$^{\circ}C$] is decreased that is 29.3% decrease.

지반-말뚝 상호작용계의 강제진동해석 (A Forced Vibration Analysis of Soil-Pile Interaction System)

  • 김민규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.136-143
    • /
    • 2001
  • In this study, a numerical analysis for soil-pile interaction systems in multi-layered half planes under a forced vibration is presented. The soil-pile interaction system is divided into two parts, so called near field and far field. The near field soil using finite elements and piles using beam elements are modeled. The far field soil media is implemented using boundary elements those can automatically satisfy the condition of wave radiation. These two fields are numerically coupled by imposing displacement compatibility condition at the interface between the near field and the far field. For the verification, the forced vibration test was simulated and the response under horizontal and vertical harmonic loads at the pile cap in the layered half plane was determined. The results are compared to the theoretical and experimental results of the literatures to verify the proposed soil-pile interaction analysis formulation.

  • PDF

진동하에서 일방향응고 시킨 $Al-CuAl_2$ 공정복합재료의 응고에 관한 연구 (Unidirectional Solidification of $Al-CuAl_2$ Eutectic Composites under Forced Convection by Vibration)

  • 이현규;이길홍
    • 한국주조공학회지
    • /
    • 제18권3호
    • /
    • pp.234-239
    • /
    • 1998
  • Unidirectional solidification of $Al-CuAl_2$ eutectic composites was studied under the condition of forced convection by vibration. It has been shown that thermal gradient for solid is different from that for liquid during solidification under force convection by vibration. With increase of vibration, mobility of liquid increases, but decreases with decreasing vibration. The rate of solidification is very high initially, and decreases suddenly. For further solidification, the rate of solidification decrceases slowly, and shows a L-type behavior. The mechanical vibration during solidification effects efficiently on nucleation, and induces a forced convection in liquid. By the forced convection, great thermal gradient of liquid interface between solid and liquid can be obtained. The amount of solute near the interface also decreases as solute distribution is improved by the forced convection.

  • PDF

강제가진조건에서 자유롭게 매달린 PVC 파이프의 와류유기진동 특성에 관한 시험 연구 (Experimental Study of VIV Characteristics of Free Hanging PVC Pipe under Forced Oscillation Conditions)

  • 권용주;정동호;박병원;정재환;오승훈
    • 한국해양공학회지
    • /
    • 제32권5호
    • /
    • pp.341-350
    • /
    • 2018
  • A series of model tests was carried out to investigate the vortex-induced vibration (VIV) characteristics of a free hanging PVC pipe under forced oscillation conditions. The prescribed displacement with a period and amplitude was forced at the top of the riser. The motion of the riser along its length was measured with underwater cameras in three dimensions. The top-excited responses in the inline direction and vortex-induced vibration in the cross-flow direction were examined in the time and frequency domains. Multi-peak frequencies in the VIV were demonstrated to be strongly dependent upon the Keulegan-Carpenter number, corresponding with the results of Blevin. It was found that the Reynolds numbers (excitation period) was a critical parameter for the dominant VIV characteristics, even under the condition of using the same Keulegan-Carpenter number, under the top-excited condition. In the resonance at the nth natural frequency by the forced-motion induced VIV frequency, the riser responded with a large amplitude and forced frequency, dominantly in the VIV CF direction.

강제배기를 이용한 굴삭기 공기조화 시스템에 관한 연구 (A Study on Air-Conditioning System for Excavator using Forced Exhaust)

  • 황지현;정찬세;고주현;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권2호
    • /
    • pp.23-29
    • /
    • 2013
  • The excavator is used in a variety of construction environments. There are many kinds of risk like falling rocks or harmful dust. The excavator cabin protects the operator not only from these harmful environments but also provides a comfortable working environment. By the way, the excavator cabin consumes a lot of energy for cabin air conditioner. For this reason, the research is required to reduce energy consumption. This study suggests the air conditioning system for excavator using forced exhaust. First, the forced exhaust system simulated by AMESim tool and surveyed the applicability. Using AMESim simulation, it was investigated the effect of cabin inside temperature by intake flow rate and intake air temperature. The experiment executed using the 1.5 ton excavator and field tested according to the intake flow rate. Finally, verified the applicability on the air conditioning system for excavator using forced exhaust.

ANALYTIC EXPRESSION OF HYDRAULIC FALL IN THE FREE SURFACE FLOW OF A TWO-LAYER FLUID OVER A BUMP

  • Park, Jeong-Whan;Hong, Bum-Il;Ha, Sung-Nam
    • 대한수학회논문집
    • /
    • 제12권2호
    • /
    • pp.479-490
    • /
    • 1997
  • We consider long nonlinear waves in the two-layer flow of an inviscid and incompressible fluid bounded above by a free surface and below by a rigid boundary. The flow is forced by a bump on the bottom. The derivation of the forced KdV equation fails when the density ratio h and the depth ratio $\rho$ yields a condition $1 + h\rho = (2-h)((1-h)^2 + 4\rho h)^{1/2}$. To overcome this difficulty we derive a forced modified KdV equation by a refined asymptotic method. Numerical solutions are given and hydraulic fall solution of a two layer fluid is expressed analytically in the case that derivation of the forced KdV (FKdV) equation fails.

  • PDF

방해물에 기인한 이층유체의 자유 계면에서의 변화 - Hydraulic Fall (Free surface flow of a Two-Layer fluid over a bump - Hydraulic Fall)

  • 최정환
    • 한국전산유체공학회지
    • /
    • 제2권1호
    • /
    • pp.129-137
    • /
    • 1997
  • We consider long nonlinear waves in the two-layer flow of an inviscid and incompressible fluid bounded above by a free surface and below by a rigid boundary. The flow is forced by a bump on the bottom. The derivation of the forced KdV equation fails when the density ratio h and the depth ratio ρ yields a condition 1+hρ=(2-h)((1-h)²+4ρh)/sup 1/2/. To overcome this difficulty we derive a forced modified KdV equation by a refined asymptotic method. Numerical solutions are given and hydraulic fall solution of a two layer fluid is expressed analytically in the case that derivation of the forced KdV(FKdV) equaition fails.

  • PDF

외력을 받는 주기적 구조물의 진동 국부화 (Vibration Localization of a Periodic Structure Undertaking External Force)

  • 김재영;유홍희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.543-548
    • /
    • 2000
  • Vibration localization of a periodic structure with mistuning is presented in this paper. Mistuning in periodic structures can lead to an increase of the forced response which is much larger than those of perfectly tuned assembly. Thus, mistuning has a critical impact on high cycle fatigue in structures, and it is of great importance to predict the mistuned forced response in efficient manner. In this paper, forced response of a coupled pendulum is investigated to identify localization effects of periodic structures. The effects of mistuning and damping on the maximum forced response are examined. It is seen that in certain condition of mistuning and coupling, strong localization occurs and this can be significant under weak damping.

  • PDF