• 제목/요약/키워드: Force measurement

검색결과 1,614건 처리시간 0.032초

로드형 피스톤의 왕복운동 저항력 측정실험 (Measuring Experiment of Resistance Force on a Reciprocating Motion of Rod Type Piston)

  • 함영복;박경민;김성동;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.486-489
    • /
    • 2003
  • To reduce lateral force of traditional plunger type piston in the swash plate type hydraulic piston pumps and motors, we have proposed rod type piston with ball joint on both ends. We have studied the theoretical reaction force on two types of piston moving in the cylinder block bore. and made an experiment for the resistance force measurement on a reciprocating motion of plunger and rod type piston, changing the test condition such as swash plate angel and supply oil pressure and so on. As a result. a rod type piston has more smaller resistance force, about 29%. than a plunger type one.

  • PDF

다축 힘센서에서 힘감지 오차의 전파 (Force-Sensing Error Propagation in Multi-Axis Force Sensors)

  • 강철구
    • 대한기계학회논문집A
    • /
    • 제24권11호
    • /
    • pp.2688-2695
    • /
    • 2000
  • In multi-axis force sensor, compliance matrices representing structural behaviour of internal sensor bodies play an important role in decoupled sensing and accuracy, Recently, error propagation through compliance matrices has been studied via approximation approach. However the upper bound of measured force error has not been known. In this paper, error propagation in force sensing is analysed in a unified way when both strain measurement error and compliance matrix error exist, and the upper bound of the measured force error is derived exactly(not approximately). The analysis is examined through a numerical example.

Stewart 플랫폼 형식의 6축 힘/토크 센서에 대한 실험적 연구 (An Experimental Study on the Stewart Platform-Based 6 Axis Froce/Torque Sensor)

  • 강철구
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.393-397
    • /
    • 1996
  • A stewart platform-based force/torque sensor with 6 elastic legs was designed and manufactured Kinematic design parameters were determined so that the force/torque sensor might have the isotropic force/torque properities. In a force/torque analysis, it was used the solution of forward kinematics by linearization of the solution of the inverse kinematics. The performance of te force/torque sensor was investigated by measurement experiments. The gravity compensation was conducted to reduce the force and torque effects by the weights of the upper plate, joints and other sensor parts.

  • PDF

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

A MOM-based algorithm for moving force identification: Part II - Experiment and comparative studies

  • Yu, Ling;Chan, Tommy H.T.;Zhu, Jun-Hua
    • Structural Engineering and Mechanics
    • /
    • 제29권2호
    • /
    • pp.155-169
    • /
    • 2008
  • A MOM-based algorithm (MOMA) has been developed for moving force identification from dynamic responses of bridge in the companion paper. This paper further evaluates and investigates the properties of the developed MOMA by experiment in laboratory. A simply supported bridge model and a few vehicle models were designed and constructed in laboratory. A series of experiments have then been conducted for moving force identification. The bending moment and acceleration responses at several measurement stations of the bridge model are simultaneously measured when the model vehicle moves across the bridge deck at different speeds. In order to compare with the existing time domain method (TDM), the best method for moving force identification to date, a carefully comparative study scheme was planned and conducted, which includes considering the effect of a few main parameters, such as basis function terms, mode number involved in the identification calculation, measurement stations, executive CPU time, Nyquist fraction of digital filter, and two different solutions to the ill-posed system equation of moving force identification. It was observed that the MOMA has many good properties same as the TDM, but its CPU execution time is just less than one tenth of the TDM, which indicates an achievement in which the MOMA can be used directly for real-time analysis of moving force identification in field.

IPMCs(Ionic Polymer Metal Composites) 성능 개선 및 날갯짓 작동기로의 응용 (Improved IPMCs and It's Application for Flapping Actuator)

  • 이순기;유영태;허석;박훈철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.723-726
    • /
    • 2005
  • The two major obstacles in the application of IPMC to flapping actuators operated in the air are solvent loss and actuation force. In this paper, solvent loss of various IPMCs made of Nafion$^{TM}$117(183$\mu$m thickness) has been experimentally investigated to find out the best combination of cation and solvent for minimal solvent loss in IPMCs and higher actuation force. For this purpose. experiments for the internal solvent loss measurement of IMPCs have been conducted for various combinations of cation and solvent. From the experiments, it was found that heavy water showed improvement in the operating time up to more than two minutes. in the tip force measurement of IPMCs, it was found that smaller and thicker IPMCs produced larger tip forces. However, the shorter IPMCs generated reduced actuation displacements and created flapping motion with decreased natural frequency. For the design of flapping device actuated by 5mm wide, 10mm long, 0.2mm thick IPMCs were used in the stacked form. Since the actuation force is a few gram-force, we stacked five IPMCs to improve actuation force. To amply the actuation force, rack-and-pin ion type hinge was used for the flapping device and insect (Cicadidae) wing was attached to the stacked IPMC actuator. In the flapping test, the device could generate flapping angle of 15$^{\circ}$ at 6Hz excitation by 2.5 voltage square wave input.

  • PDF

100 kN Deadweight Force Standard Machine and Evaluation

  • Park Yon-Kyu;Kim Min-Seok;Kim Jong-Ho;Kang Dae-Im;Song Hou-Keun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.961-971
    • /
    • 2006
  • A deadweight force standard machine is a mechanical structure that generates force by subjecting deadweights to the local gravitational field. The Korea Research Institute of Standards and Science (KRISS) developed and installed a 100 kN deadweight force standard machine for national force standards. It can generate forces from 2 kN to 110 kN in increments of 1 kN. The uncertainty of the force machine was estimated and declared as $2\times10^{-5}$. This 100 kN deadweight force machine was compared with the 500 kN deadweight force standard machine at KRISS and the 20 kN and 50 kN deadweight force standard machines at the National Metrology Institute of Japan (NMIJ). The measurement results showed good agreement between the deadweight force machines, and the accuracy level of the 100 kN deadweight force machine was verified.

30ft급 쌍동형 세일링 요트의 선체 유체력 계측에 의한 세일력 추정방법에 관한 연구 (A Study on the Sail Force Prediction Method for Hull Hydrodynamic Force Measurement of 30feet Catamaran Sailing Yacht)

  • 장호윤;박충환;김헌우;이병성;이인원
    • 대한조선학회논문집
    • /
    • 제47권4호
    • /
    • pp.477-486
    • /
    • 2010
  • During sailing by wind-driven thrust on the sail, a catamaran sailing yacht generates leeway and heeling. For predicting sail force, a model test was carried out according to running attitude. Through the model test, drag and side force of the real ship was predicted. A purpose of this study is to find sail force to C.E from changed attitude during running direction. By balance of hull and sail, a heeling force of designed sail is predicted. Also through heeling force and driving force, total sail force and direction from C.E are considered with changed mast including leeway and heeling.

Design and Contact Force Control of a Flip Chip Mounting Head system

  • Kim, Kyoung-Jun;Shim, Jae-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1060-1065
    • /
    • 2003
  • This paper contributes to development of a new chip mounting head system for flip chip. Recently, the LDM(Linear DC Motor) has been widely used, because it has particular merits than the rotary type motors. In this paper, we proposed a macro/micro positioning system for force control of a chip mounting system. In the proposed macro/micro system, the macro actuator provide the system with a gross motion while the micro device yields fine tuned motion to reduce the harmful impact force that occurs between very small sized electronic parts and PCB surface. In order to prove the effectiveness of the proposed macro/micro chip mounting system, we compared the proposed chip mounting head with the conventional chip mounting head equipped with a macro actuator only. A series of experiments were executed under the mounting conditions of various access velocities and PCB stiffness. As a result of this study, a satisfactory voice coil actuator as the micro actuator has been developed, and its performance meet well the specifications desired for the design of the chip mounting head system and show good correspondence between theoretical analysis and experimental results.

  • PDF

근전도의 정량적 분석시 사용되는 수리적 파라미터의 민감도 비교 (The Comparison of Sensitivity of Numerical Parameters for Quantification of Electromyographic (EMG) Signal)

  • 김정룡;정명철
    • 대한산업공학회지
    • /
    • 제25권3호
    • /
    • pp.330-335
    • /
    • 1999
  • The goal of the study is to determine the most sensitive parameter to represent the degree of muscle force and fatigue. Various numerical parameters such as the first coefficient of Autoregressive (AR) Model, Root Mean Square (RMS), Zero Crossing Rate (ZCR), Mean Power Frequency (MPF), Median Frequency (MF) were tested in this study. Ten healthy male subjects participated in the experiment. They were asked to extend their trunk by using the right and left erector spinae muscles during a sustained isometric contraction for twenty seconds. The force levels were 15%, 30%, 45%, 60%, and 75% of Maximal Voluntary Contraction (MVC), and the order of trials was randomized. The results showed that RMS was the best parameter to measure the force level of the muscle, and that the first coefficient of AR model was relatively sensitive parameter for the fatigue measurement at less than 60% MVC condition. At the 75% MVC, however, both MPF and the first coefficient of AR Model showed the best performance in quantification of muscle fatigue. Therefore, the sensitivity of measurement can be improved by properly selecting the parameter based upon the level of force during a sustained isometric condition.

  • PDF